Search

149 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 19
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 7
    Manufacturer
  • Made in
  • 30
    Additional
    Loading...
View:
149 products
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
Measurement of the power of the ambient dose equivalent and the ambient dose equivalent of neutron radiation, as well as simultaneous monitoring of the power of the ambient dose equivalent and the ambient dose equivalent of gamma radiation. A wide energy range Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4 Audible and visual alarm of exceeding threshold levels
Produced in: Belarus, Minsk
Oscilloscope S1-167/2
Oscilloscope S1-167/2
Designed for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0 - 25 MHz with a built-in multimeter measuring voltage and DC power, the average square value of voltage and AC power, DC electrical resistance. Technical specifications: Vertical deviation Number of channels 2 Bandwidth 0-25 MHz Deviation coefficients 2 mV/div-10 V/div (step 1-2-5) Installation error ± 3% Rise time of PH <= 14 nsec Input impedance 1 mOhm/23 pF, with divider 1:10-10 mOhm/12 pF with open input <=110 V with closed input <=110 V with divider 1:10 <= 250 V range U post. U AC: 1 mV–500 V Error 0.1% (U post); 0.3% -1% (U perem. 40 Hz–100 kHz) Range I post., I AC.: 1 mA–2 A Error: 0.25% (I post.); 0.5% (I perem. 40 Hz–5 kHz) R Range: 1 Ohm–1 mOhm Error R: 0.2% 3.5-digit indicator Automatic selection of limits.
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-23M
Measuring antenna P6-23M
Technical specifications: Frequency range (0.85 - 17.44 GHz) Standing Wave Coefficient (SWR) < 1.7 Effective area at least in the frequency range - from 0.85 to 15 GHz > 150 cm2 - from 15 to 17.44 GHz > 110 cm2 The margin of error of the effective area in the frequency range, no more - from 0.85 to 8.5 GHz ± 20% - from 8.5 to 17.44 GHz ± 15% Orthogonal polarization signal level -25 dB The level of the side lobes, no more than -10 dB Ambient temperature -50°C - 50°C Gabbar dimensions (HxWxD) 887x351x265 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
DOSIMETRIC GAMMA RADIATION DETECTION UNITS
DOSIMETRIC GAMMA RADIATION DETECTION UNITS
Gamma radiation Detection Units (BDKG-04, BDKG-22, BDKG-23, BDKG-23/1, BDKG-24, BDKG-25, BDKG-30, BDKG-32, BDKG-35, BDKG-36, BDKG-38, BDKG-204, BDKG-224, BDKG-230) are designed to use as part of stationary and mobile radiation monitoring posts and robotic devices for ground, aviation and marine applications.
Produced in: Belarus, Minsk