Search

149 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 19
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 7
    Manufacturer
  • Made in
  • 24
    Additional
    Loading...
View:
149 products
Digital oscilloscope C8-39
Digital oscilloscope C8-39
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Technical specifications: Vertical deviation :2 Number of channels 0-50 MHz Rise time of PH ≤ 7.0 ns Input impedance 1 ± 0.03 mOhm, 25 pF Deviation coefficients of 5 mV/div - 2 V/div (step 1-2-5) The maximum input voltage is 100 V With a divider of 1:10 250 V The error of amplitude measurements is a≤ 2 % 5 mV...2 V; 10 ns...2 s/del. ADC: 2 channels, 50 MHz, 8 bits Equivalent sampling rate of 2.5 GHz Marker measurements U: ±2.5%, T: ±1.5% Pre-launch 8 screens, post-launch 150 screens Simultaneous observation of 2 signals Cursor measurements DU and DT Averaging modes and automatic DU and DT measurements LCD screen - 320x240 dots (monochrome) RS 232C interface Dimensions, weight 176x280x80 mm, 3 kg Power supply: +12V, 230B
MNIPI
Minsk
Produced in: Belarus, Minsk
Microassembly RB1S8KN009
Microassembly RB1S8KN009
Two-channel analog switch with signal summation function Designed for use in oscilloscopes with a bandwidth up to 350 MHz. Technical specifications: The value of the voltage between the outputs of the switch at load resistance RN = (50 ± 2.5) ohms and opening voltages UU1 = (2.0 ± 0.2) V and locking UU2 = (4.2 ± 0.2) V channels supplied alternately to the corresponding inputs (start 1, start 2) of the switches must be: in the absence of an input signal from minus 0.1 to plus 0.1 V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of the open channel (0.45 ± 0.1) V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of both open channels (0.45 ± 0.1) V
MNIPI
Minsk
Produced in: Belarus, Minsk
Support and rotary device OPU-2
Support and rotary device OPU-2
Technical specifications: Azimuth rotation angle from 0° to 360° with a reading of 0.1° The angle of rotation according to the angle of the place from minus 30° to plus 90° with a count of 0.1° The angle of rotation of the polarization plane from minus 95° to plus 95° with a count of 1° The installation height of the axis of the orientation mechanism is from 1.35 to 2.5 m. Note – The maximum height is determined when the rack is installed, the smooth lifting mechanism is fully extended and the legs are fully extended to the stop, extended at an angle of 30° to the axis of the azimuth mechanism. Smooth height adjustment of the axis of the orientation mechanism 0.25 m In terms of strength under climatic and mechanical influences, the rotary support device (OPU) complies with the norms of group 6 GOST 22261-94 Overall dimensions of the OPU - 1687x2500 (shown in the unfolded state at maximum height. The size Ø1687 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the OPU on a horizontal platform) Operating conditions of the OPU: ambient temperature from minus 50 to plus 60 ° C The mass of the OPU is 19.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-20
Immitance meter E7-20
Technical specifications: Wide frequency range 25 Hz–1 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.04 – 1) V RS-232C interface Mathematical processing of measurements Dimensions, weight: 127x298x300 mm, 4 kg Power supply ~220 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters Ch3-81, Ch3-81/1
Frequency meters Ch3-81, Ch3-81/1
Designed to measure the frequency or single and averaged period of sinusoidal and pulse signals, as well as to measure the pulse duration and frequency ratio, with a guaranteed measurement error of up to 10-7za year. Description: Ch3-81 (inputs A, B, C) – range 0.1 Hz–2.5 GHz Ch3-81/1 (inputs A, B) – range 0.1 Hz–200 MHz Frequency measurement, frequency ratios Measurement of the period, duration of 1 microsecond–10000 s Signal level 30 mV–10 V (eff.), pulse up to 30 V Thermostated quartz 5 MHz: ±10-7 (year) ±7.5X10-9(day) Frequency temperature departure: ±2.5X10-8 (+5...+40 °C) Number of averaged periods: 1-104 Timestamps 10-7-10-3 s RS-232 interface 8-bit SD indicator Dimensions, weight 80X220X300 mm, 3 kg Power supply: ~ 220V, 20V
MNIPI
Minsk
Produced in: Belarus, Minsk
RADIOMETER RKS‑AT1329
RADIOMETER RKS‑AT1329
The radiometer allows you to: - measure the total alpha and total beta activity of counting samples based on aerosol analytical filters of the AFA type; - measure the total alpha and total beta activity of "thick-layer" counting samples prepared from the sample substance (for example, by evaporation or by any other method that provides a "thick" sample); - measure the total alpha and total beta activity of "thin-layer" counting samples prepared from the sample substance (for example, by electrolytic deposition); - measure activity, flux density, external alpha and beta radiation for sources of type 1P9, 2P9, 3P9, 1C0, 2C0, 3C0; - control radiation contamination of surfaces by smears. Device control and measurement data processing is performed by an external PC The possibility to use custom calibrations The possibility to select units of measurement LED stabilization of the measuring path Passive lead protection against background radiation The possibility to maintain a measurement database Methodological support of measurements
Produced in: Belarus, Minsk
SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
Monoblock design Multifunctionality A built-in GPS module Audible, vibration and visual alarms The possibility of connecting external detection units Battery life 25 h (AT6102A,V),18 h (AT6102)
Produced in: Belarus, Minsk
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
Water distiller AWD-3000F
Water distiller AWD-3000F
Distillers of the company "BELAKVILON" are designed to produce distilled water from tap water. 3 — 3.5 l/h Dimensions (mm), W x D x H 410 x 335 x 490 Heater 3.0 kW Cooling water consumption, l/h about 30 — 50 l/h Power supply 230 V ±10%, 50 Hz Switch Differential automatic Water level sensors Reed floats
Produced in: Belarus, Minsk
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk