Search

188 products
View:
  • Selected: 1
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • Applying
  • 74
    Names
    Loading...
  • 11
    Manufacturer
  • 12
    Made in
  • 9
    Additional
View:
188 products
AC voltage source B2-9
AC voltage source B2-9
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET. Technical specifications Output voltage setting range (SCR) from 25 to 250 V The discreteness of the output voltage setting is 0.05 V The frequency setting range of the output voltage is from 40 to 500 Hz The discreteness of the output voltage frequency setting is 0.05 Hz Output electrical power, not less than 1000 VA The basic error of setting the output voltage is ± (0.005 Uv + 0.5 V) The basic error of setting the output voltage frequency is ± 0.1 Hz Additional error in setting the output voltage caused by a change in the load current from the maximum value to zero ± 0.5 V Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 0.5 V Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 1300 VA Overall dimensions, mm 343x160x352 Weight, not more than 6.5 kg
Produced in: Moscow
 Electronic Stopwatch-Meter IVPR-203M
Electronic Stopwatch-Meter IVPR-203M
from 30 940 ₽
The electronic stopwatch - time parameter meter IVPR-203M is a universal small-sized device of a new type for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
FNCH-45
FNCH-45
Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Bandwidth Fh-Fb at the level of -1 dB, GHz 37-45 The barrage band at the level of -30 dB, GHz 50-70 Bandwidth loss, 0.5-1.0 dB
Produced in: Moscow
Rubidium frequency standard H1-1013
Rubidium frequency standard H1-1013
Its small dimensions, weight, power consumption, and operating time allow it to be widely used as an embedded source of high-stability signals in frequency measuring devices and complexes, telecommunications systems, navigation and communication systems.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Device for measuring attenuation DC1-28
Device for measuring attenuation DC1-28
The device is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 interfaces (CPC). Technical specifications Frequency range from 100 kHz to 37.5 GHz VSWR input of the device with a matching fixed attenuator attenuation of 10 dB, depending on the frequency range, no more • from 100 kHz to 180 MHz 1.15 • from 0.18 to 2 GHz 1.25 • from 2 to 12 GHz 1.30 • from 12 to 17.85 GHz 1.50 • from 17.85 to 37.5 GHz 2.00 Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 125 VA Overall dimensions, mm 216x493x508.5 Weight, not more than 32 kg
Produced in: Moscow
Frequency meters H3-96
Frequency meters H3-96
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 3200 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz The number of averages. the period of the input signal is 1 ... 105 Borehole measurement by inputs – 1.000001- 999999999 Frequency ratio in channels: A/S, C/A, B/C and B/A - up to 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 2•10-8 - in 30 days, ± 5•10-8 - in 12 months Overall dimensions (HXHL) - 345x285x106 mm Weight: 4 kg Reference generator: ±5x10-8 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk