Search

727 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 206
    Names
    Loading...
  • 55
    Manufacturer
    Loading...
  • 35
    Made in
    Loading...
  • 52
    Additional
    Loading...
View:
727 products
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal mobile complex for verification and repair of measuring instruments
Universal mobile complex for verification and repair of measuring instruments
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
Produced in: Moscow