Search

129 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 120
    Names
    Loading...
  • 28
    Manufacturer
    Loading...
  • 16
    Made in
  • 53
    Additional
    Loading...
View:
129 products
MX-10 Magnetometer
MX-10 Magnetometer
from 80 400 ₽
The MX-10 magnetometer is an auxiliary tool for conducting magnetic powder control using permanent magnets, rectified current electromagnets by the applied field method, as well as for monitoring by the residual magnetization method according to the requirements of the current regulatory documentation. The MX-10 magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities, etc. Magnetometer MX-10 is an electronic measuring unit with a remote measuring converter, which is based on the Hall effect. The design of the device allows measuring both the normal and tangential component of the magnetic induction vector directly on the surface of the part. The measured value of the magnetic field induction value is displayed on the digital indicator of the electronic unit. Features and Benefits The updated version of the MX-10 magnetometer has a modern element base, which has significantly improved its performance, reduced error and expanded the measurement range (see the Table of Technical characteristics). The device is capable of operating in two modes: Constant measurement mode. This is convenient when carrying out a large number of measurements over a short period of time. Automatic shutdown mode 1 minute after measurement. It allows you to save the charge of the device, which is especially important in the field. A thermal compensation circuit ensures stable measurement readings at any temperature change. Other features include: The small dimensions of the Hall measuring transducer for the MX-10 magnetometer make it possible to measure the induction of the magnetic field in grooves, grooves, angular transitions, i.e. in those areas of the controlled product that are stress concentrators and are most dangerous from the point of view of cracking; A wide range of measurements of the magnitude of the magnetic field induction; The smallest measurement error among analogues in the entire operating temperature range; Convenience of measurement by a remote measuring transducer in various planes; Low power consumption and, as a result, long working time; Low cost compared to similar models on the market; Compact dimensions; Manufacturer's warranty – 12 months; The device is included in the state register of measuring instrument RU.C.27.004.A No. 36079 dated 01.09.2009 and has undergone a verification procedure. Magnetometer MX-10 (milliteslameter) it is also included in the register of measuring instruments, test equipment and measurement methods used in JSC "Russian Railways". Scope of application 1. Verification of the magnetization modes of controlled parts using permanent magnets, rectified current electromagnets by the applied field method, as well as during the control by the residual magnetization method, by measuring the tangential and normal components of the magnetic field strength vector at one or more points on the surface of these parts. The number of points at which the magnetic field strength is measured and their location on the controlled surface depend on the shape of the part, as well as on the type and design of the magnetizing device used. 2. Control of the magnetization of parts before welding. During electric arc welding of non-magnetized parts, the effect of "magnetic blowing" is observed, i.e. the deviation of the electric arc from the axis of the electrode, the wandering of the arc end along the product, which leads to metal splashing during welding, deterioration of the seam quality. Therefore, before welding, it is necessary to measure the level and direction of magnetization of the parts and demagnetize them if necessary. 3. Verification of the residual magnetization after magnetic powder inspection. Demagnetization and verification of the residual magnetization of responsible, rubbing parts, as well as parts in contact with them after assembly, is prescribed in the requirements of the IPC and is a technological stage of control. 4. Magnetization control before assembling various structures. Magnetized parts can affect the operation of automation devices, cause errors in the readings of instruments, equipment. Magnetization can cause the accumulation of wear products in the movable joints, cause a negative effect on subsequent technological operations. Due to possible undesirable consequences, the parts are demagnetized and the quality of their demagnetization is checked. 5. Control of gas and water meters. Housing and utilities enterprises may also be interested in the device. It is known that existing gas or water flow meters can be easily "deceived" with the help of strong permanent magnets that reduce the rotation speed of the flow sensors. There are different ways to detect such theft. One of them is the control of the residual magnetization of the counters using magnetometers. The measured value should not significantly exceed the Earth's magnetic field, otherwise it can be concluded that there was unauthorized interference with the operation of the device. Main technical characteristics Measuring range, MT from 0.1 to 100 The limits of the permissible basic absolute measurement error, MT D = 0.02 VI + 0.05, where VI is the magnetometer readings in MT Power supply battery type: PP3 (nine-volt battery) Consumption current, mA, no more than 15 Duration of continuous operation (from fully charged batteries), h, at least 20 Overall dimensions, mm: – electronic unit (LxWxH) 120x60x25 – Measuring transducer (Diameter x Length) 18x173 Weight, g, not more than 160 Ambient operating temperature, °C -10...+40
Produced in: Moscow
measuring air-thermal installation  ASESH-8-2
measuring air-thermal installation ASESH-8-2
1 supp.
Implements a thermogravimetric (air-thermal) method for determining the mass fraction of moisture, based on measuring the mass of the sample of the analyzed substance before and after drying, followed by calculating the values of the mass fraction of moisture. Air-thermal measuring installations ASESH-8 are registered in the State Register of Measuring Instruments under No. 58526-14, have a certificate of approval of the type of measuring instruments OC.C.31.005 And No. 56847.The installations undergo initial verification and have the appropriate certificate. General characteristics: - The presence of two independent drying chambers. - Possibility of simultaneous determination of humidity of 12 samples: Each drying chamber of the installation consists of 6 independent cells. You can put 2 buckets in each cell. Total capacity of the ASES Installation-8-2 – 24 bucs. - Convenient access to the cells of the drying chamber: On the front side of the cabinet there are four doors for access to the cells. - Natural ventilation: The absence of rotating elements ensures absolute noiselessness of operation and a long service life. - Built-in timer: The ASESH-8-2 installation has 4 timers, by means of which the end of the drying process is monitored in each section with the output of an audible signal and a light indication. - The output to the operating mode is 30 minutes: The power of air-thermal installations is 1200 watts. When entering the operating mode, the power consumption is the same as that of similar cabinets with low power. SCOPE OF DELIVERY : 1. Installation of ASESH-8-2 2. AO-3 cooler 3. Auxiliary accessories 4. Air-heat control unit: 5. Interface unit for connecting a personal computer with a scale (available on request); 6. software for processing and archiving measurements of humidity determination data; The program allows you to: Set the operating temperature in the chambers via a personal computer Set the necessary parameters of the sample drying process according to the selected method Display all current processes (predrying, drying, cooling) and parameters (temperature, time) during the tests. To monitor the process by means of an electronic timer with the output of an audible signal. Record all weighing results. Perform humidity calculations in accordance with standardized methods. To calculate the humidity with pre-drying, the program uses formulas that allow you to get an accurate result. Archive and print test results. According to the test results of FSUE "UNIIM", it is recommended to use a laboratory mill of the BLIZZARD series for sample preparation. SCOPE OF APPLICATION: 1. Crop production, agriculture and forestry. 2. Products of meat, dairy, fish, flour-milling, feed and microbiological industries. 3. Food industry products. 4. Cellulose, paper, cardboard and products made from them. 5. Medicines, chemical and pharmaceutical products and medical products. 6. Building materials. 7. Products of the logging and sawmilling and woodworking industry. 8. Ground, soils, mineral fertilizers. Technical specifications: The measurement range of the mass fraction of moisture, % from 0.5 to 80 Operating temperature range, °C from 45 to 160 The error of setting and maintaining the temperature in the working area, ° C, not more than 2.0 Limits of permissible absolute error, % ± 0.5 Power consumption, V• A, not more than 1200 Overall dimensions, mm 240 × 260 × 640 Overall dimensions of the cell, mm 75 x 40 x 165 (depth) Weight, kg 28.4
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
UNM-300/2000 portable magnetizing device
UNM-300/2000 portable magnetizing device
The principle of operation of the magnetic particle flaw detector: The device provides monitoring and detection of surface defects by the applied field method or by the residual magnetization method. The kit with the device includes power cables, remote solenoids, and an electromagnet, with which you can produce longitudinal or circular magnetization of the part. A trolley is provided for the transportation of technical equipment and the detection of defects in the field. Magnetization is carried out by alternating, direct or pulsed current of large magnitude, due to which high values of the magnetizing field strength are achieved. Features and advantages of the UNM-300/2000 magnetic powder control device: Microprocessor control, which allows you to memorize and accurately reproduce the desired modes and selected measurement parameters, as well as work as part of automated stands and control systems; The magnetizing device has a digital indicator on the front side and a control panel for selecting the operating mode, type and current strength; Automatic recognition of the type of connected external magnetizing device; Device temperature control and automatic shutdown in case of overheating; Remote connected magnetization devices allow you to control the quality of parts and assemblies of complex shape; Automatic demagnetization of controlled assemblies and parts; The equipment meets the requirements of the following standards: GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006; Devices of the MANUL series (UNM-300/2000 and others) are approved for use by the Russian Railways. Scope of application: Magnetic particle flaw detection is indispensable where quality control of various critical and loaded assemblies and parts is required, detection of surface defects that occur during their production, storage and operation. The device may be in demand: at factories for the production and repair of automotive, aviation and railway equipment, metro enterprises, military-industrial complex (inspection of shafts, axles, wheel pairs, pistons, beams, springs, etc.); in civil and military shipbuilding, elevator and crane enterprises (control of rigging equipment, hooks, etc.); at pipe rolling plants (determination of defects in rolled products); in the oil and gas, chemical industry (inspection of welds of equipment operating under pressure). The UNM-300/2000 portable magnetic particle flaw detector has a relatively small weight and dimensions, which allow it to be used as a stationary or portable device in specialized quality control laboratories or in ordinary workshops, garages, hangars, locomotive depots or warehouses. The UNM 300/2000 device, as well as other means of magnetic powder control, are normally used together with auxiliary equipment for the preparation and application of magnetic powder (suspension), for fixing the indicator pattern, magnetometers for determining residual magnetization, visual inspection means – magnifiers and endoscopes, as well as with ultraviolet irradiators in the case of fluorescent powders. Technical specifications Magnetization currents Variable, Pulse, Rectified (only for solenoid and electromagnet) The measurement error of the magnetization current is no more than 10%. characteristics of the pulse current The repetition frequency of unipolar current pulses during magnetization and of multipolar current pulses during demagnetization is (2 ± 0.2) Hz. The duration of the current pulses is at least 1.5 ms. Magnetic characteristics of the solenoid The maximum alternating magnetic field in the center of a single solenoid is at least 100 A/cm. The maximum alternating magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 60 A/cm. The maximum permanent magnetic field in the center of a single solenoid is at least 80 A/cm. The maximum permanent magnetic field on the axis in the center between two solenoids located at a distance of 200 mm is at least 50 A/cm. Values of magnetization currents The maximum alternating magnetization current in the unwound cable 6 m × 50 mm2 and on the electrical contacts is at least 1000 A. The maximum pulse magnetization current in an unwound cable of 4 m × 10 mm2 and on electrical contacts is at least 2000 A. The current adjustment range in the solenoids and the electromagnet is from 0.5 to 4.5 A. Characteristics of the electromagnet The maximum alternating magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 75 A/cm; - in the 40 mm gap: at least 300 A/cm. The maximum constant magnetic field in the air gap of the electromagnet depending on the interpolar distance is as follows: - in the 140 mm gap: at least 100 A/cm; - in the 40 mm gap: at least 400 A/cm. Operating mode The operating mode is cyclic: magnetization/pause. The magnetization time is adjustable from 1 to 40 s. The demagnetization time is adjustable from 5 to 60 seconds. Demagnetization of details is performed automatically. The time of setting the operating mode is no more than 15 seconds. The duration of continuous operation is at least 8 hours. Power supply parameters The device is powered by an alternating current network with a voltage of 220 V and a frequency of 50 Hz. The power consumed from the network is no more than 5 kVA. weight and size characteristics Overall dimensions of the device (w × h × d) – no more than 267×245×465 mm. The weight of the device is not more than 50 kg. Other characteristics The average worktime before failure is at least 12500 hours. The average recovery time is no more than 6 hours. The average service life of the device is at least 10 years. Compliance with standards The device fully complies with the requirements of GOST R 56512-2015, GOST R 53700-2009 (ISO 9934-3:2002), GOST R 50.05.06-2018, GOST R ISO 10893-5-2016, GOST ISO 17638-2018, RD 34.17.102-88 and RD-13-05-2006 in terms of the requirements for magnetizing devices and magnetic particle flaw detectors. Identification of the load. It performs automatic identification of the types of connected load: cables, solenoids and electromagnet. Control of the connected load current It allows you to control the current of the connected AC/DC electromagnets and solenoids.
Produced in: Moscow
MTP-01 Magnetic Coating Thickness Gauge
MTP-01 Magnetic Coating Thickness Gauge
from 90 000 ₽
Measuring range of thickness of protective coatings, mm: from 0.2 to 10 Digital display of measurement results: yes Power supply: from a PP3 type battery with a voltage of 9V Power consumption, MW: 100 Operating mode setting time, min: 1 Time of one measurement, sec: 3 Memory capacity, number of thickness values: 2000 Overall dimensions, mm: - electronic unit (width-depth length) 120x60x25 - measuring transducer (diameter height) 33x23 - connecting cable (length) 1500±300 Weight, g, no more: - electronic unit (without battery power) 80 - measuring converter 40 The kit includes: - Electronic unit, - Measuring converter - Plate made of non-magnetic material for setting the upper limit of measurements - Battery type PP3 - CD-ROM with the program - Prism - Cover - Spring - Case - Passport - Operation Manual
Produced in: Moscow