Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared Fourier spectrometer "InfraLUM® FT-08"
Infrared Fourier spectrometer "InfraLUM® FT-08"
1 supp.
Technical specifications: Operating spectral range, cm-1 from 400 to 7800 Spectral resolution, cm-1, not more than 0.7 The limit of the absolute error of the wavenumber scale, cm-1 ± 0.05 Signal-to-noise ratio (RMS) for the wavenumber 2150 cm-1, determined in the range ± 50 cm-1 for a resolution of 4 cm-1 and an accumulation time of 60 s, at least 40,000 The limit of deviation of the 100% transmission line from the nominal values for the wave number 2150 cm-1, determined in the range ± 50 cm-1, % ± 0.2 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system, % ± 0.25 The time of setting the operating mode of the spectrometers, h, no more than 2 Continuous operation time of spectrometers, h, not less than 8 Power consumption, In × A, not more than 65 Overall dimensions, mm, not more than 580x550x340 Weight, kg, not more than 32 Average time to failure, h, not less than 2500 Average service life of the spectrometer, years, at least 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Climatostat V3 (TU 26.51.-70-002-63790925-2021)
Climatostat V3 (TU 26.51.-70-002-63790925-2021)
from 460 000 ₽
1 supp.
Climatostat V3 (TU 26.51.-70-002-63790925-2021)- it has a new unique control unit UB-04T with a touch screen. This climatostat is universal, it combines the advantages of climatostats B2 and P2, and, accordingly, can perform the functions of one and the other. It is intended for performing works on biotesting the toxicity of aquatic environments on daphnia and ceriodaphnia crustaceans, as well as microalgae (scenedesmus, etc.) in controlled environmental conditions. In the climatostat, it is possible to install exposure devices of the type (UER or similar) and to carry out the exposure of samples under conditions of rotation of samples with test organisms in a plane located at an angle to the horizontal. This ensures the intensification of gas exchange of liquid samples with the external environment. A slow rotation ensures complete uniformity of conditions (temperature, lighting, gas exchange) in all samples, including control, and as a result - high reproducibility of the biotest conditions and reproducibility of the test results. The climatostat has an on-board network for connecting additional sample exposure devices, 5 (five) preset modes and 8 (eight) user modes for free programming of the climatostating parameters by the operator. It is intended for carrying out biotesting (according to the methods of Zhmur N.S., "Aquaross" 2001, 2007), Grigorieva Y.S. (SFU)., Terekhova V.A. (MSU, LATAP), hazard assessment of nanomaterials according to the methods of Morgalev Yu.N. (TomSU) and others. Used with test objects: Crustaceans Daphnia Magna (Daphnia magna Straus); Crustaceans Ceriodaphnia affinis (Ceriodaphnia affinis); Crustaceans of salty reservoirs Artemia Salina (Artemia salina L); Algae Scenedesmus (Scenedesmus quadricauda). Algae chlorella (Chlorella vulgaris Beijer), etc. Additional features of the controller (UB-04T): - setting the contrast of information display - sound notification of an open door - audio notification of the end of the biotest - graphical intuitive parameter setting scales - Fully Russian-language menu and Russian-language design of all text information of the interface - 3 (three) preset modes with the exact name and a brief description of the techniques (can be increased or decreased at the request of the Customer) - quick correction of backlight brightness in preset modes (two touches) - fast temperature correction of temperature control in preset modes (two touches) - 8 user modes (the number of modes can be increased or decreased at the request of the customer when ordering) - graphical intuitive scales for adjusting the brightness of lumostating, temperature of thermostating, automatic adjustment of the photoperiod (with one touch) - built-in countdown timers for setting the exposure time in the biotest (up to 180 days with a minimum discreteness of 1 min) - notification of the power failure of the device during the test - error notification - the ability to update the controller firmware directly by the user at the place of operation - quick reset to factory presets
Evropolitest
Ivanteevka
Produced in: Moscow region, Ivanteevka
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
from 150 000 ₽
1 supp.
The Europolitest company continues to release its "bestseller" cultivator KVM-05. This cultivator was developed and produced jointly with the Candidate of Biological Sciences prof. Grigoriev and LLC "Omikron", LLC "SFU-System" Krasnoyarsk. Since 2021, due to the reorganization of the production chain, the production of cultivators of the KVM series has been established by Europolitest LLC in the mode of a full production cycle. The thermophilic strain of chlorella algae has been widely used in ecocontrol laboratories, biotests with this test object are by far the most automated biotests that allow reducing time at all stages of work (building up the uterine culture, sample exposure in the biotest, registration of the test function). Cultivator KVM-05 is a long-lived among cultivators of this purpose and a standard of reliability, reproducibility and durability. Used in techniques: - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles by changing the optical density of the Chlorella algae test culture (Chlorella vulgaris Beijer). FR.1.39.2010.09103; MVI 1/25-2010. - Methodology for determining the toxicity of samples of surface fresh, groundwater, drinking water, wastewater, water extracts from soil, sewage sludge and waste by changing the optical density of the chlorella algae culture (Chlorella vulgaris Beijer). MON F T 14.1:2:3:4.10-04 / 16.1:2.3:3.7-04 FR.1.31.2009.06642. - Methodology for determining the toxicity of drinking, natural and wastewater, water extracts from soils, sewage sludge and waste by changing the relative index of delayed fluorescence (OPF) cultures of chlorella algae (Chlorella vulgaris Beijer) HDPE F 14.1:2:4.16-09 / 16.1:2.3.3.14-09.
Evropolitest
Ivanteevka
Produced in: Moscow region