Vibration velocity sensors with current output DVST-1
Vibration velocity sensors with current output DVST-1
Vibration velocity sensors with a current output DVST-1 are designed to convert the RMS value of the vibration velocity of an object into a standard current signal of 4-20 mA.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
IR microscope "MIKRAN-3"
IR microscope "MIKRAN-3"
A higher–level device with extreme sensitivity and an additional set of functions that allow you to expand the possibilities for conducting spectral studies: · revolver mechanism with 4 interchangeable lenses - mirror IR 15X, NPVO, lens 4X, lens 10X; · registration of spectra in the modes of specular and diffuse reflection, transmission and NIP; · increased sensitivity, which allows recording the spectra of micro-objects with sizes from 5 microns; · built-in control panel with advanced functions; · automated mapping system; · the rectangular slit diaphragm is made of special glass – after the fragment is selected, the rest of the field of view is also available to the user, which greatly simplifies photometry of extended surfaces with local inhomogeneities; · specialized software for controlling the microscope and processing the results. Liquid nitrogen is required to work with an IR microscope.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Vibration converter VT-003
Vibration converter VT-003
The VT-003 vibration transducers are designed to convert the instantaneous value of the vibration acceleration of an object into an ICP signal of the IEEP standard.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Kepler-10b Vacuum furnace
Kepler-10b Vacuum furnace
Horizontal vacuum resistance furnaces are designed for carrying out various technological processes in high vacuum at temperatures up to 1600 degrees. The furnace can be used in electronic, radio engineering, aviation, rocket and other industries. The main areas of application are the technological processes of annealing, quenching, degassing and sintering.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Vacuum and crimping chambers
Vacuum and crimping chambers
Vacuum chambers can be used: for drying materials (low vacuum), testing spacecraft, during experiments on plasma retention and antimatter production, as elements of charged particle accelerator systems and systems for applying thin films. Vacuum chambers can be used: for drying materials (low vacuum), testing spacecraft, during experiments on plasma retention and antimatter production, as elements of charged particle accelerator systems and systems for applying thin films.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
 Portable kit for magnetic particle flaw detection Pole-M1
Portable kit for magnetic particle flaw detection Pole-M1
The Pole-M1 kit is used for monitoring pipelines, cranes, stanchions, beams and other ferromagnetic products, machine-building parts and workpieces for the presence of surface and subsurface defects (cracks, shells, etc.). It is designed to work in workshop, laboratory and field conditions. A permanent magnet allows you to monitor various shaped parts, welds and various products for cracks, discontinuities, shells and similar defects by magnetizing individual controlled areas or the product as a whole. The permanent magnet as part of the Polyus-M1 set of highly stable magnets with high maximum specific magnetic energy is designed to detect surface and subsurface defects in products made of ferromagnetic materials by magnetic powder or magneto-luminescent method and refers to portable specialized means of magnetic control.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
OptoTL-60/125 interferometer by Opto-TL
OptoTL-60/125 interferometer by Opto-TL
The OptoTL-60/125 interferometer by Opto-TL is designed for non-contact technological control of the shape accuracy (N/ΔN) of optical polished flat and spherical surfaces with a diameter of up to 125 mm, measuring their radii, and also for checking the distortion of lens wavefronts. Characteristic features of the interferometer OptoTL-60/125: • small dimensions for placement in production next to optical machines; • specially developed original FastInterf software for operational measurements in production conditions; • original ruler calibration program for measuring radii; • the presence of two monitors for quick adjustment and visualization of the interference pattern; • New! the presence of two light sources (coherent and non-coherent) to reduce the influence of reflection of the second side when testing plane-parallel plates (option); • motorized fast vertical movement by servomotor; • motorized precise vertical movement using a pulse generator with a sensitivity of 30 nm; • New!automatic vertical movement by a specified amount (from the «cat's eye» position to the confocal position and vice versa) (option); • two standard sizes of reference lenses 60 mm and 125 mm with adapter 60/125; • adjusting table for tilting and moving the controlled samples; • the presence of base surfaces for the table and controlled parts to simplify alignment when controlling a batch of identical parts; • device for tilting steep blocks (option); • base and vertical stand made of syntegran for better damping of vibrations; • passive system of vibration isolation sufficient for work in industrial conditions; • The interferometer is delivered on a turnkey basis, complete with everything you need to get it up and running.
OPTO-TL
Санкт-Петербург
Produced in: Saint Petersburg
Monochromator "MHD-2"
Monochromator "MHD-2"
Technical specifications: Range of operation 280-710 nm Diffraction grating (replica) 1250 strokes per millimeter The area of maximum energy concentration 350-450 nm The working order of the spectrum is the first The signal-to-noise ratio on the line is 632.8 nm when detuning from the center of the line by ± 3.3 nm is not worse than 3 * 106 times The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slits is 5 mm The resolution of the monochromator with these slits is not worse than 0.34 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions are not more than 335 x 153 x 240 mm Weight is not more than 8 kg Supply voltage 187-242 V Power consumption not more than 12 watts Current frequency 49-51 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
IR microscope "MIKRAN"
IR microscope "MIKRAN"
The IR microscope "MIKRAN" is designed to work with IR Fourier spectrometers "Infralum FT-801". The spectral range is 6000 – 600 cm-1 (with a microscope and an MST detector cooled with liquid nitrogen). Resolution 0.5, 1, 2, 4, 8 cm-1 (determined by the resolution of the Fourier spectrometer)
SIMEKS
Novosibirsk
Produced in: Novosibirsk