Search

396 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 142
    Item names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • 36
    Additional
    Loading...
View:
396 products
EVRASAMP ES Sampling of the required configuration
EVRASAMP ES Sampling of the required configuration
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Sampler type: with a ladder - oval shape, circle Operating temperature range (depending on the type of sampler): from 1460°C to 2020°C Selection time: from 3 to 5 seconds Tube length: from 100 to 1500 mm (other length is possible on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
Produced in: Lipetsk
PKV-IP-7,2×3,4
PKV-IP-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Vibration converter VT-002
Vibration converter VT-002
The VT-002 vibration transducers are designed to convert the instantaneous value of the vibration acceleration of an object into an ICP signal of the IEEP standard.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Frequency meters Ch3-81, Ch3-81/1
Frequency meters Ch3-81, Ch3-81/1
Designed to measure the frequency or single and averaged period of sinusoidal and pulse signals, as well as to measure the pulse duration and frequency ratio, with a guaranteed measurement error of up to 10-7za year. Description: Ch3-81 (inputs A, B, C) – range 0.1 Hz–2.5 GHz Ch3-81/1 (inputs A, B) – range 0.1 Hz–200 MHz Frequency measurement, frequency ratios Measurement of the period, duration of 1 microsecond–10000 s Signal level 30 mV–10 V (eff.), pulse up to 30 V Thermostated quartz 5 MHz: ±10-7 (year) ±7.5X10-9(day) Frequency temperature departure: ±2.5X10-8 (+5...+40 °C) Number of averaged periods: 1-104 Timestamps 10-7-10-3 s RS-232 interface 8-bit SD indicator Dimensions, weight 80X220X300 mm, 3 kg Power supply: ~ 220V, 20V
MNIPI
Minsk
Produced in: Belarus, Minsk
Electronic milk viscometer "Expert Somatos - 02"
Electronic milk viscometer "Expert Somatos - 02"
from 69 000 ₽
1 supp.
Exclusive benefits: • version with one or two flasks, which allows up to 60 measurements per hour • optionally equipped with an integrated or external printer • * thanks to the new verification method developed from a blank sheet, it can be checked at any standardization and metrology center As a rule, it is used: • Dairy farms — for the timely prevention and treatment of mastitis in cows, which ensures stable supplies of high-grade milk (accordingly increases the cost of products). • Veterinary laboratories, SBBS, points for receiving farm milk from the population to determine the grade and calculate the cost of raw milk. • In the laboratories of milk processing enterprises to control incoming raw milk.
LABORATORIKA
Krasnoobsk
Produced in: Novosibirsk region
PKV-IB-7,2×3,4
PKV-IB-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
Blue DPSS Laser 445nm KLM-445-x
Blue DPSS Laser 445nm KLM-445-x
DPSS lasers of the KLM-445/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes. Technical specifications Radiation output power: up to 120W Radiation wavelength: 445 nm Output beam diameter: 1.5mm Divergence of the radiation beam: 1.3 mrad Instability of radiation power: 5% Type of modulation: TTL or analog Time to enter the mode: 15min Spectral line width: 0.1nm
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
IPEP-1 Electrostatic Field Parameter Meter
IPEP-1 Electrostatic Field Parameter Meter
Designed to measure the potentials of electrostatically charged objects, the strength of the electrostatic field and the surface density of electric charges. Technical specifications: Measuring range 0.02-50 kV The error is 5-10% The intensity of the electrostatic field Measuring range 2-1000 kV/m Error 5% Surface density of electric charges Measuring range 0.02-10 µcl/m2 Error 5% Measurement of the electrostatic field strength (2-1000 kV/m) Measurement of the potential of charged objects (0.02–50 kV) Measurement of surface charge density (2x10-8–1x10-5Kl/m2) Measurement error ±(5-10) % Laser pointer of the distance to the object (2, 10 cm) 3.5-digit indicator (LCD with image flip) RS-232C interface Dimensions, weight 40x106x268 mm, 0.7 kg Built-in battery for 8 hours of operation Power supply: ~220, 5 VA, 4.5–5.5 VA battery
MNIPI
Minsk
Produced in: Belarus, Minsk
Optical Transceiver WDM OC-12/STM-4 (622 Mbps)
Optical Transceiver WDM OC-12/STM-4 (622 Mbps)
from 5 373 ₽
Optical transceivers are available in 9-pin plastic cases with a combined optical input/output for SC type connectors.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg