Search

619 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 195
    Names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
619 products
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
from 4 314 ₽
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Copper Transceiver SFP 10/100/1000Base-T
Copper Transceiver SFP 10/100/1000Base-T
from 2 175 ₽
Receiving and transmitting modules for electrical communication lines in SFP metal cases with separate optical input/output for an RJ-45 type electrical connector to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk
Metolab 502 Vickers Hardness Tester
Metolab 502 Vickers Hardness Tester
The stationary METOLAB 502 hardness tester is a modification of the METOLAB 501 series device, equipped with a display and a digital micrometer that allows you to automatically read values without the need for conversion tables. The device also automatically calculates the hardness of the samples. The METOLAB 502 microhardometer is designed to measure the hardness of various samples and products (steels, cast iron, non-ferrous metals and soft alloys) according to the Vickers (HV) and Knup (HK) scales in full compliance with GOST R ISO 6507-1-2007. The device has high accuracy, performs measurements in a wide range and with high repeatability. The stationary automatic METOLAB 502 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 502 Micro-Vickers hardness tester: Built-in digital micrometer that allows you to automatically read readings without the need for translation tables; Automatic hardness calculation; Simple and intuitive control of the device, fully Russified menu; Wide range of measured values – from 5 to 2500 HV; A wide range of applied test loads - 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Large and bright LCD display. Basic delivery package: Stationary METOLAB 502 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
Salt low-temperature bath SHS-6.5.6,2/5,5
Salt low-temperature bath SHS-6.5.6,2/5,5
from 2 561 724 ₽
Salt baths (furnaces) are used for low tempering of steels, annealing and heating for hardening of aluminum alloys, for tempering aluminum alloys, for tempering high-speed steel and for the first stage of heating high-speed steel. The low-temperature saltpeter bath SHS-6.5.6.2/5.5 is designed for heat treatment of parts in a saltpeter melt at temperatures up to 550 ° C in stationary conditions.
Produced in: Tula
Trace searcher Success AG-308.10N
Trace searcher Success AG-308.10N
from 146 400 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with LED indication and a compact autonomous generator with an output power of up to 20 watts and a range of up to 3 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
Tracing generator AG-114.1
Tracing generator AG-114.1
from 94 530 ₽
The automatic tracing pulse generator AG-114 is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. Features of the AG-114 generator The selected output power (5 W at 1...1000 ohms, 10 W at 1...500 ohms, 20 W at 1...250 ohms) is issued automatically. The ability to work on such high load resistances allows you to trace very extensive communications. Low power provides energy saving and small "readjustments" to neighboring objects, high power provides a high range of broadcast and detection. Three generation modes: pulse – the main high-efficiency mode with high intelligibility against interference; continuous – an additional low-cost mode for short-term special measurements; three–frequency mode, which provides the selection of the optimal frequency on a remote receiver without switching the transmitter (generator). Three generation frequencies: 512 Hz, 1024 Hz, 8928 Hz. Lower frequency – less "readjustment" to neighboring objects, higher frequency – higher detection range. Unusually compact (190x140x80 mm), for such a high output power (20 W), the autonomous design is provided by the use of highly efficient technology "CLASS D (BD)" (pulsed output power amplifier with an efficiency of 80%). As a result, one small-sized autonomous battery with a capacity of only 2.2 Ah provides pulse generation for >5 hours at maximum output power (20 watts). It is possible to work with "recharge" from the charger or increase capacity by connecting an external battery to increase the time resource. The control and display system, which contains only 4 large keyboard switches and 2 LEDs with specific signatures and symbols ("intuitive interface") and is not overloaded with unnecessary, for automatic devices, fine-tuning organs and indicators of numerical parameter values, is designed for convenient operation in the field. The device does not require constant supervision, parameter monitoring, frequent operational switching and is designed to work on the principle of "turned on and went to the track". In case of significant changes in the load resistance (communication) during generation, the device is automatically reconfigured ("repeated auto-negotiation").
Produced in: Kolomna, Moscow region
Low-frequency signal generator G3-131A
Low-frequency signal generator G3-131A
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 2 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min Signal amplitude ±5 V at 600 ohm load ±10 V without load Limits for adjusting the output signal level from 1 mV to 3.75 V (scr) at a load of 600 ohms from 2 mV to 7.5 V (scz) without load Signal level unevenness ± 2% at frequencies from 20 Hz to 200 kHz relative to 1 kHz ± 5% at frequencies from 200 kHz to 2 MHz Harmonic coefficient ± 0.3% at frequencies from 2 to 20 Hz ± 0.2% at frequencies from 20 Hz to 100 kHz ±1% at frequencies from 100 kHz to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2
MNIPI
Minsk
Produced in: Belarus, Minsk
Quenching water tank BZV – 10.12.15/0.8
Quenching water tank BZV – 10.12.15/0.8
Heating chamber power, kW 40 Supply voltage, V 380 ±15% Frequency, Hz 50 Number of phases 3 Maximum operating temperature, oS 80 The range of automatic temperature control, oS From 20 to 80 Stability of automatic temperature maintenance, oS ±6 Environment in the workspace Water, oil, polymer liquid. Warm-up time to maximum temperature, h 1,5 Heating control Digital controller Workspace dimensions: width,mm 1000 depth, mm 1200 height, mm 1500 Overall dimensions of the product: width (without control cabinet), mm 1800 depth, mm 2100 height, mm 2750 Weight, kg 700 Working hours, hours per day/days per week 24/5
Produced in: Tula
AK-1000 Acoustic calibrator
AK-1000 Acoustic calibrator
characteristics The AK-1000 is recommended for use with OCTAVE-101A, OCTAVE-101AM, OCTAVE-110A, OCTAVE-110A-ECO, OCTAVE-121, OCTAPHONE-110, OCTAVE-201, ECOPHYSICS-110A sound meters. The AK-1000 can be used for calibration of acoustic measuring paths with VMK-205, MK-265, MR-201, M-201, MK-233 microphones, and other ½-inch microphones. technical specifications Reproducible ultrasound, dB (rel. 20 µPa): 94 and 114 The limits of the permissible basic error of the reproducible ultrasound, dB: ± 0.25 Limits of the permissible additional error of the ultrasound caused by a change in ambient temperature in the operating temperature range, dB: ± 0.08 Frequency of the reproduced sound pressure, Hz: 1000 Limits of the permissible basic relative error of reproduction of the sound pressure frequency, %: ± 0.7 Limits of the permissible additional relative error of the sound pressure frequency caused by a change in ambient temperature in the operating temperature range, %: ± 0.07 Coefficient of nonlinear distortion, %, not more than: 2.5 Weight (with batteries), kg, no more than: 0.250 Overall dimensions (length×diameter), mm, no more: 158×35 Operating conditions: - ambient temperature, ° C: from minus 10 to 50 - relative humidity (at 40 ° C), %, not more than: 90 - atmospheric pressure, kPa: from 65 to 108
Produced in: Moscow