Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Technical specifications: Melt flow rate for 10 min, g 0,1 - 99,9 The dimensions of the capillary opening, mm dia. 2,095 diam. 1,048 (optional) diam. 1,180 (optional) Set of loads, kg 0,325-5 10-21,6(optional) Temperature range in the working chamber, °C +50...+450 Accuracy of temperature maintenance, °C: - in the range of 50...300 °C: ± 0.1 - in the range of 300...350 ° C: ± 0.2 - in the range of 350...450°C: ±0.3 The discreteness of setting the temperature of the chamber, ° C 1 Time to enter the operating mode, no more, min 40 Power supply, V/kW 220/0.8 Installation dimensions, WxDxH mm 513x445x590 (920 – Maximum height with a fully loaded polymer chamber and a full stack of loads with a handle for their installation) Installation weight, not more than 70 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
IMK-30 Torsion testing machine
IMK-30 Torsion testing machine
Technical specifications: Maximum load (torque): 30 N·m Maximum twisting angle: 50000° The discreteness of the twisting angle: 0.01° Twisting angle error: ±0.1° Torque discreteness: 0.001 N·m Relative error of torque measurement: no more than 1% in the measurement range from 0.6 to 30 Nm Torque measurement error: no more than 0.01 N·m in the measurement range from 0 to 0.6 N · m Maximum rotation speed: 10 rpm Weight: 150 kg Overall dimensions (length x width x height): 1000 x 500 x 500 mm Diameter of the universal testing device: 80 mm Maximum spring length: 300 mm or more
Produced in: Ivanovo
Optical transceiver Bi-directional 1x9 receptacle/OS3/STM1/FastEthernet (155Mbps)
Optical transceiver Bi-directional 1x9 receptacle/OS3/STM1/FastEthernet (155Mbps)
from 5 741 ₽
Optical transceivers are available in 9-pin plastic cases with a single optical input/output for SC type connectors.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Trace Searcher Success AG-309.20M (frost-resistant)
Trace Searcher Success AG-309.20M (frost-resistant)
from 188 370 ₽
The trace searching kit is designed to accurately determine the location and depth of underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), troubleshooting cable lines, and also allows you to conduct a survey of the area in the shortest possible time and with great reliability before excavation and to prevent damage to engineering communications. As part of the kit, the receiver is in the form of a monoblock with a frost-resistant LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line. Compact stand-alone generator with display and built-in induction antenna. The output power of the generator is up to 20 watts and the operating range is up to 3 km.
Produced in: Kolomna, Moscow region
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Microphone condenser capsule M-101
Microphone condenser capsule M-101
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Electrolysis plant
Electrolysis plant
A hydrogen production plant is a special equipment designed to produce hydrogen gas and oxygen by electrochemical decomposition of water into its main elements (in short, electrolysis of water). Today there are three ways to implement the electrolysis technology of hydrogen production, differing in the type of electrolyte used and the conditions of electrolysis. The electrolysis plant has a modular type of construction. A standard stationary installation consists of one or more electrolysis units and one process unit. The number of electrolysis units depends on the performance of the installation and the need to reserve electrolyzers (for objects of increased responsibility).
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
CD-1 Paint detector of defects 220V
CD-1 Paint detector of defects 220V
from 60 000 ₽
The principle of operation: The controlled extended product (pipe, rolled or wire) is passed through the working area of the flaw detector. When a defective area is detected, the flaw detector included in the automated system sends a signal to trigger the paint meter actuator, as a result of which the paint from the marker's aerosol can is applied to the surface of the controlled product through a window in the device housing. Features and benefits: - Any standard aerosol cans with a diameter of 68 mm can be used in the flaw detector; - Easy replacement of the cylinder; - The device does not require connection to the pneumatic line; - High performance; - The design of the CD-1 defect meter allows connection to any standard AC and DC electrical networks with rated voltages from 12 to 380 V. Scope of application: The CD-1 automatic paint sprayer is an auxiliary equipment and is used in conjunction with flaw detectors as part of in–line automated lines for marking defects in quality control of extended products made of various materials, ferrous and non-ferrous metals and alloys - welded, hot-rolled and cold-drawn pipes, rolled products, wire and products made of them. The flaw detector can be used both in the production process and during input control on the consumer side at machine-building, transport, chemical and oil and gas enterprises. *Custom-made versions for rated voltages can be of: 12, 24, 48, 110, 127, 220, 380V.
Produced in: Moscow
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow