Search

619 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 195
    Names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
619 products
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
KOIDZ-VD Sets of samples of artificial defects and gaps
KOIDZ-VD Sets of samples of artificial defects and gaps
from 0 ₽
KOIDZ-VD kits consist of samples of artificial defects (SAD) and samples of gaps (SG). Samples of artificial defects are made in the form of flat and curved plates and cylinders, on the working surfaces of which defects are made in the form of continuity violations like slits of various depths, opening widths and lengths. The working surfaces of flat SADs are two opposite surfaces on which longitudinal slits are cut by an electroerosion method The working surfaces of the SAD, reproducing a positive curved surface, are samples with a cylindrical surface. The working surface of the SAD reproducing negative curvature is the inner surface of the curved plate — the place of inflection. The KOIDZ-VD kit contains an SAD for determining the influence of various quantities. To determine the effect of the roughness of the working surfaces, the kit contains SADs with different roughness, on which defects of the same depth are made. To determine the effect of positive curvature and surface roughness, the kit contains cylindrical samples with different roughness of working surfaces on which defects of the same depth are made. To determine the simultaneous effect of negative curvature and surface roughness, the kit contains curved plates on which two defects of the same depth are cut, one of which is located on the flat, the other on the curved parts of the sample. To determine the effect of the chemical composition of the material of the controlled products, the kit contains samples of steel 10, steel 20 and steel 45. The same defects are made on each sample. To account for the influence of specific electrical conductivity, the kit contains samples from non-magnetic structural materials: aluminum alloy D16T and titanium alloy VT-23. The same defects are made on each sample. Gap samples are flat and curved plates of different thicknesses made of dielectric material. Technical specifications The range of nominal values of the depth of defects, mm: from 0.1 to 10. The limits of permissible error of the value of the depth of defects, mm: from ± 0.02 to ± 0.25. The range of nominal values of the width of the opening of defects, mm: from 0.03 to 0.15. The limits of the permissible error of the width of the opening of defects, mm: from ± 0.01 to ± 0.05. The range of nominal values of the length of defects, mm: from 6 to 100. The limits of permissible error of the value of the length of defects, mm: from ± 0.5 to ± 1. The range of nominal values of the thickness of the dielectric gap samples, mm: from 0.2 to 10. The limits of the permissible error of the thickness of the samples, mm: from ± 0.02 to ± 0.5. The range of nominal values of the radius of curvature of curved surfaces with defects, mm: - convex: from 13 to 510; - concave: 10.
Produced in: Moscow
NEUTRON RADIATION DETECTION UNITS
NEUTRON RADIATION DETECTION UNITS
Neutron radiation detection units (BDKN-01, BDKN-02, BDKN-03, BDKN-04, BDKN-05)
Produced in: Belarus, Minsk
Green DPSS Laser 526 nm KLM-526-x
Green DPSS Laser 526 nm KLM-526-x
DPSS lasers of the KLM-526/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Correlational leakage detector Iskor-325ND
Correlational leakage detector Iskor-325ND
from 758 310 ₽
It is intended for: – determination by the correlation method of the location of liquid leakages from pipelines of household and drinking water supply, hot water supply, heating and other pipeline systems, provided that the transported medium in the pipeline is under pressure; – tracing underground utilities; – clarification of leakage sites by acoustic leak detector; – diagnostics of shut-off valves; – creation of an information database of the condition of pipelines and the results of pipeline diagnostics.
Produced in: Kolomna, Moscow region