UCHX3-53
UCHX3-53
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low phase noise value; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 °C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 12,50- 17,86 / 37,50- 53,57 Losses (max.), dB 17 Input power level, 15-20 dBm Unevenness of output power (Rvh. = 20 dBm), dB ± 2.0 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 3.5/1.5 mm (socket) • Output Waveguide 5,2x2,6 mm Overall dimensions, mm 34x20x20 Weight, g 60
Produced in: Moscow
Universal frequency meter Ch3-95
Universal frequency meter Ch3-95
The frequency meter is capable of operating both autonomously and as part of automated measuring systems with interfaces such as BUSB, RS-232, ETNET and IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (37.5 – 78.33) GHz Pulse duration 5 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng Setting range of trigger levels (inputs A, B) from -2 to 2 V The error of setting the trigger levels (inputs A, B) ± 0.01 V Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 10.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) 0.5 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 24 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x130,5x433 Weight, not more than 8.5 kg
Produced in: Moscow
PKV-IB-5,2×2,6
PKV-IB-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
PS-78 (waves.)
PS-78 (waves.)
Strobe converters are used as input devices of radio measuring equipment: amplifasometers, frequency meters, spectrum analyzers, circuit analyzers, etc.; in systems of synchronization and frequency stabilization of microwave generators, heterodynes, frequency synthesizers. Basic properties: Wide frequency range; Minimal losses and uneven conversion; High "decoupling" of channels; Large dynamic range of input signals; Harsh operating conditions Operating conditions Operating temperature range from minus 10 to 50 °C; Relative humidity up to 98% at a temperature of 25 ° C. Technical specifications Frequency range: • Microwave signal, GHz 37.5-78.33 • heterodyne, GHz 2.0-6.0 • IF, MHz 0-1000 Conversion losses *>, 30-40 dB by the 20th garm. The power level of the heterodyne, dBm 20-22 Connector type: • Microwave signal input P-waveguide with transitions to 5,2x2,6 and 3,6x1,8 mm • 1HR heterodyne input • IF output two woofer inputs
Produced in: Moscow
AC voltage calibrator H5-5
AC voltage calibrator H5-5
The calibrator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 (CPC). Technical specifications Ranges of reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 MHz from 3 MV to 3 V - over 100 MHz to 2000 MHz from 30 MV to 3 V Errors in the reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 kHz ± (0.066 – 0.8)% - over 100 kHz to 100 MHz ± (0.85 – 2.5)% - over 100 MHz to 700 MHz ± (1.5 – 12.7)% - over 700 MHz to 2000 MHz ± (4.3 -14.0)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 180 VA Overall dimensions, mm 495x217x411 Weight, not more than 24 kg
Produced in: Moscow
Universal frequency meter Ch3-89
Universal frequency meter Ch3-89
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
Produced in: Moscow
Universal frequency meter Ch3-86A
Universal frequency meter Ch3-86A
The frequency meter is capable of operating both independently and as part of automated measuring systems with an interface such as USB, RS-232 or IEEE-488 (CPC). Technical specifications Frequency and period of sinusoidal and video pulse signals (input A) 0.005 Hz - 100 MHz Frequency of sinusoidal and video pulse signals (input to) 0.01 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (0.6 - 17.85) GHz Pulse duration 10 ns - 10000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from 0 to 10000 s The frequency ratio of the two signals is up to 109 The average value of the carrier frequency of the pulse-modulated (IM) signal (input D) (0.6 - 17.85) GHz Frequency measurement resolution 2x10-10 s/Rng Phase difference of two synchronous sinusoidal signals from minus 180° to 180° Measurement error of the phase difference of two synchronous sinusoidal signals ± 0.36° (from 1 kHz to 1 MHz)±3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 30 MW - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •inputs C, D (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz; 220 V, 400 Hz Power consumption, no more than 50 VA Overall dimensions, mm 229x136x435.5 Weight, not more than 7.5 kg
Produced in: Moscow
Universal frequency meter Ch3-92
Universal frequency meter Ch3-92
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Pulse duration 10 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng The range of setting the trigger levels (inputs A, B) from minus 2.5 to 2.5 V The error of setting the trigger levels (inputs A, B) ± 0.05 V Input signal level: • for sinusoidal signal (inputs A, B) (0.03 - 10.0) V • for video pulse signal (inputs A, B) (0.1 - 10.0) V • for sinusoidal signal (input C) 50 MW - 5 MW Input resistance • Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF • Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x136x436,5 Weight, not more than 8.5 kg
Produced in: Moscow
Generator of test pulses G9-1A
Generator of test pulses G9-1A
The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg