Oxygen installations
Oxygen installations
An oxygen plant is a set of special equipment designed for the production of oxygen from atmospheric air by short–cycle non-heating adsorption. Composition of a typical oxygen plant: Air compressor Dehumidifier Main Filter Block Air receiver Oxygen Adsorption Generator Oxygen receiver
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
DC power supply B5-79/1
DC power supply B5-79/1
The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
Produced in: Moscow
Oxygen concentrator "Provita-30MS"
Oxygen concentrator "Provita-30MS"
Devices capable of generating oxygen have found the widest application in various fields of medicine. The equipment is also used in training centers, educational institutions and oxygen rooms. Medical oxygen concentrators allow to accelerate the recovery of patients suffering from cardiovascular diseases, chronic respiratory diseases, as well as other pathologies that make it difficult to saturate the blood with oxygen. This equipment is a mandatory equipment of the departments of anesthesiology and resuscitation. Oxygen concentrators demonstrate high efficiency in restorative treatment. Unlike oxygen sources, which use compressed gas, generators are characterized by high safety and efficiency Capacity: 30 l/min 1.8 m3/h 2.4 kg/h Oxygen purity: 95 % Oxygen pressure: 4-5 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
Kepler-10b Vacuum furnace
Kepler-10b Vacuum furnace
Horizontal vacuum resistance furnaces are designed for carrying out various technological processes in high vacuum at temperatures up to 1600 degrees. The furnace can be used in electronic, radio engineering, aviation, rocket and other industries. The main areas of application are the technological processes of annealing, quenching, degassing and sintering.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Vibration transducers DN-3-M1 are designed to measure vibration by converting mechanical vibrations into electrical signals proportional to the vibration acceleration of an oscillating object. Vibration converters DN-3-M1 are used in conjunction with vibration measuring devices in factory and laboratory conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Oxygen concentrator "Provita-140M"
Oxygen concentrator "Provita-140M"
Devices capable of generating oxygen have found application in various fields of medicine. The equipment is also used in training centers, educational institutions and oxygen rooms. Medical oxygen concentrators allow to accelerate the recovery of patients suffering from cardiovascular diseases, chronic respiratory diseases, as well as other pathologies that make it difficult to saturate the blood with oxygen. The concentrator is a mandatory equipment of the departments of anesthesiology and intensive care. Oxygen concentrators demonstrate high efficiency in restorative treatment. Unlike oxygen sources that use compressed gas, generators are safe and economical. Capacity: 140 l/min 8.4 m3/h 11.2 kg/h Oxygen purity: 95 % Oxygen pressure: 4-5 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Adsorption dryers with cold regeneration
Adsorption dryers with cold regeneration
The Provita company offers adsorption dryers with cold and hot regeneration of its own production. Industrial installations are equipped with high-quality components that ensure reliability and long service life. They are capable of operating at a pressure of 4 to 16 bar and are drained to a TRD (dew point under pressure) of -70 ° C. Working pressure: 4 — 16 bar Dew point: -20 to -70°C Capacity: from 50 to 5000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg