Search

178 products
View:
  • Selected: 1
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • Applying
  • 60
    Names
    Loading...
  • 12
    Manufacturer
  • 13
    Made in
  • 10
    Additional
View:
178 products
Mobile laboratory for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH)
Mobile laboratory for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH)
Laboratory equipment for 0.4-10 kV cable lines and cable lines made of cross-linked polyethylene (ETL-10/SNH) 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 50 kV. 2. SNCH test facility • – Sinusoidal 0-24 kV peak, symmetrical (error ± 1%); • – Rectangular 0-30 kV peak, symmetrical (error ± 1%); • – Constant 0-30 kV of both polarities (error ± 1%); • – Output current 0-30 mA resolution 1 ma (error ±1%); • – Resistance range 0.1 Mohm -15 Mohm; • – The frequency of the output signal is 0.01-1 Hz in increments of 0.01 Hz, automatic frequency selection. 3. Burning installation • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low–voltage cables); - Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method. 7. Autonomous gasoline generator • – Rated power 7.5 kVA.
Produced in: Kolomna, Moscow region
PKE-A Energy Tester
PKE-A Energy Tester
The devices are designed for: measurements and registration of the main indicators of the quality of electrical energy established by GOST 32144-2013 (GOST R 54149-2010) with registration of protocols according to GOST 33073-2014; measurements and registration of the main parameters of electrical energy in single-phase and three-phase electrical networks (including the effective values of voltages and currents with sinusoidal and distorted curves; active, reactive and full electrical power); measurements of parameters of secondary circuits (load capacity of measuring transformers and voltage drop) in electric energy metering systems and electric energy losses in power supply lines. functional test and verification of connection of meters of active and reactive power and energy, energy measuring converters of voltage, current at the places of their operation; functional test and verification of the connection of single-phase and three-phase electric energy meters without breaking current circuits to detect theft of electricity; measurements of electricity losses in the power supply line. The PKE-A energy tester provides registration with subsequent transfer to a personal computer (PC) of statistical data on the PKE: Values of the PCE according to GOST 30804.4.30 (GOST P 51317.4.30) and GOST 30804.4.7 (GOST P 51317.4.7) with a registration depth of 512 days; Values and durations of voltage dips and overvoltages; Values of the short-term dose of flicker; Parameters of the electrical network and vector diagrams with the depth of registration: - 24 hours for averaging time of 3 s, - 200 days for averaging time of 10 min. The program "Energy Monitoring ES" provides the formation of quality control protocols in the form of GOST 33073-2014.
Marsenergo
Saint Petersburg
Produced in: Saint Petersburg
Universal calibrator H4-301
Universal calibrator H4-301
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range UK 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, Uk 2; 20 V 0.15 + 0.02 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V from 20 Hz to 20 kHz Basic error, ± (% of U + % of Uk): sv. 20 to 40 kHz 0.2 + 0.1 Uk 200 V; 600 V: from 40 Hz to 1 kHz 0.2 + 0.05 Power reproduction range Ik 200 Ma 0.1 + 0.02 DC: from 1 Ma to 5 A, Ik 2; 20; 200 mA 0.1 + 0.01 sub-bands (Ik) 200 Ma; 2; 20; 200 mA; 2; 5 A Ik 2 A; 5 A 0.1 + 0.02 Basic error, ± (% of I + % of Ic): AC power reproduction range: from 10 Ma to 5 A sub-bands (Ic) 200 Ma; 2; 20; 200 mA; 2; 5 A 0.15 + 0.05 Frequency range from 20 Hz to 1 kHz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 °C to + 50 °C Dimensions; weight 420×342×184.5 mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Mobile laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10)
Mobile laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10)
Laboratory for 0.4-10 kV cable lines based on a trailer (ETL-10) includes: 1. Test facility – Maximum rectified voltage up to 70 kV; – Maximum AC voltage of the industrial frequency of 50 Hz to 50 kV. 2. Burning facility – Maximum voltage up to 30 kV; – Maximum current up to 80 A; – Working hours are not limited; – Switching stages is carried out without breaking the arc at the time of switching; – The ability to start working from any stage of burning (when working with low–voltage cables); - Built-in afterburning. 3. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where the pipeline and cable intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method. 6. Autonomous air heater Planar – An autonomous air heater Planar with a capacity of 2 kW or an analog with a 7.5 l fuel tank.
Produced in: Kolomna, Moscow region
Leakage detector with passive cable detection function Success ATP-204
Leakage detector with passive cable detection function Success ATP-204
from 114 540 ₽
• Designed for: • – detection of depressurization sites of underground pipelines of heat, water, gas, oil supply systems located at a depth of up to 3 m in channel and without channel laying. • – traces of hidden communications (cable lines, pipelines) in passive mode. • – surveys of the excavation area (before opening the route for the presence of cables, pipelines that complicate excavation).
Produced in: Kolomna, Moscow region
Tracer detector for diagnostics of non-metallic and metal pipelines Athlete TEK-120TUZ
Tracer detector for diagnostics of non-metallic and metal pipelines Athlete TEK-120TUZ
from 329 400 ₽
A frost-resistant kit with a powerful generator that solves problems on metal and non-metallic pipelines designed for: • – search for underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), as well as determining the depth of their occurrence and places of damage. • – determination of the location of power cable lines by induction and acoustic methods. • – high-range tracing and highly efficient search for cable damage sites. • – tracing of non-metallic and metallic pipelines by acoustic method and search for leaks from pipelines.
Produced in: Kolomna, Moscow region
Cable searcher Athlete AG-319M (frost-resistant)
Cable searcher Athlete AG-319M (frost-resistant)
from 338 100 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with a frost-resistant LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line and the most powerful multi-frequency generator in the TECHNO-AC line, with a range of up to 10 km.
Produced in: Kolomna, Moscow region
Trace searcher with the function of saving GPS/GLONASS coordinates Success AG-309.60K
Trace searcher with the function of saving GPS/GLONASS coordinates Success AG-309.60K
from 282 210 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). As part of the kit, the receiver is in the form of a monoblock with a large LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line. Built-in GPS\GLONASS module for determining and recording the coordinates of the location of communication. "Probe" mode for tracing NON-METALLIC communications using an in-tube generator (optional). The generator has increased power up to 180 watts and a range of up to 5 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
Power supply B5-78
Power supply B5-78
Technical specifications: B5-78 (15 V, 3 A); B5-78/1 (30 V, 2 A); B5-78/2 (50 V, 1 A); B5-78/4 (20 V, 1.5 A); B5-78/6 (30 V, 4 A); B5-78/7 (50 B, 2.5 A) Voltage measurement error: ±0.3 V Current measurement error: ±(0.04–0.06) A Voltage instability when the load current changes 0.03% Instability of the current when the voltage changes at a load of 0.2% Voltage ripple 0.5–1 mV Current ripple 0.1% Power consumption 90 - 320 VA Two 3-digit indicators (voltage, current) Adjustments are rough, smooth Dimensions 115x185x360 mm Weight: 3.7 kg (B5-78, B5-78/1, B5-78/2) 3 kg (B5-78/4) 5.5 kg (B5-78/6, B5-78/7) Power supply ~220 V A
MNIPI
Minsk
Produced in: Belarus, Minsk
Cable Finder Success KBI-309N
Cable Finder Success KBI-309N
from 106 260 ₽
Description of the cable finder Success KBI-309N • – Traceroute receiver in the form of a monoblock with a large LCD display. • – The image of the route on the device screen. • – Automatic calculation and display of the depth of the communication up to 10 m, as well as the current in the line. Purpose of the cable finder Success KBI-309N • – Search for live electrical cables. • – Search and tracing of underground utilities (gas pipelines, pipelines, power and telephone cables). • – Determination of the occurrence of underground utilities at a depth of up to 10 m. Features of the AP-019.1 receiver • – Modern digital traceriscover receiver-monoblock AP-019.1. • – The image of the route on the device screen. • – Automatic calculation and display of the depth of communication and current in the line. • – Several options for displaying information on the receiver indicator: "Route", "Graph", "Graph+", "Minimum maximum", modes "Relative distance to communication" and "2-frequencies" allow the operator to use the device's capabilities as efficiently as possible. • – Additional functions when connecting external sensors. • – Wide range of operating frequencies (50(60) / 100(120) / 512 / 1024 / 8192 / 32768 Hz, wide band 40...8000 Hz, radio 8...40 kHz). • – Menu in two languages (Russian and English).
Produced in: Kolomna, Moscow region
Cable Finder Success KBI-106
Cable Finder Success KBI-106
from 54 600 ₽
Digital tracer device with LED scale and audio output to the operator's headphones. Extremely easy to use and in a compact, lightweight case. Designed for: • – search for live electrical cable lines. • – search for places where the pipeline and cable intersect. • – determination of the occurrence of underground utilities at a depth of up to 6 m . Features of the AP-014 receiver • – Digital traceroute receiver. • – Additional LED indication of the signal level. • – Wide range of operating frequencies (50 / 100 / 512 / 1024 / 8192 / 32768 Hz, Wide Band 50...2000 Hz). • – Frost-resistant, working at temperatures up to -30 ° C. • – Lightweight, compact housing.
Produced in: Kolomna, Moscow region