Search

726 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 214
    Names
    Loading...
  • 47
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 35
    Additional
    Loading...
View:
726 products
Stand for measuring the electrification of tissues (to the device ST-01)
Stand for measuring the electrification of tissues (to the device ST-01)
from 17 200 ₽
Method of measuring the electrostatic field strength", SanPiN 2.4.7/1.1.1286-03 "Hygienic requirements for clothing for children, adolescents and adults", MOOK 4.1/4.3.1485-03 "Hygienic assessment of clothing for children, adolescents and adults". (available on a separate order).
Produced in: Moscow
Installation for measuring radio technical characteristics of dielectric materials
Installation for measuring radio technical characteristics of dielectric materials
Designed for: measurements of the relative permittivity and the tangent of the dielectric loss angle of materials at a frequency of 9 GHz in accordance with GOST R 8.623-2015 "GSI.
VNIIFTRI
Mendeleevo
Produced in: Moscow region, Mendeleevo
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
COMBI-01M (VE-meter (Modification AT-004), ST-01, MAS-01)
from 289 000 ₽
A set for measuring the levels of electrostatic and magnetic fields, the concentration of light negative and positive aeroions.
Produced in: Moscow
VOLTAMMETER PARMA VAF-A(M2)
VOLTAMMETER PARMA VAF-A(M2)
It will help relay protection and automation services, the chief power engineer of industrial enterprises and a wide range of specialists engaged in setting up, monitoring, diagnostics and operation of electrical installations to solve the following tasks: − control phase alternation − remove the voltage characteristics − measure phase shift angles and build vector diagrams of voltage and current − control the circuits in the SHPT − check the integrity of electrical conductors − carry out operational maintenance of relay protection circuits and power circuits of electrical installations − monitor the condition and diagnose DC circuits − carry out phasing when setting up differential protection and connecting current and voltage transformers, electric motors − check the correct connection of electricity meters − determine the harmonic composition of current and voltage (up to and including the 19th harmonic)
PARMA
Saint Petersburg
Produced in: Saint Petersburg
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
from 375 000 ₽
Frequency ranges: from 48 to 52 Hz, from 5 Hz to 400 kHz, from 10 kHz to 30 MHz, from 30 to 300 MHz, from 30 to 50 MHz, from 300 MHz to 18 GHz. three - coordinate antennas; large amount of built-in memory for recording measurement results; high measurement accuracy; the meter is provided with a two-year warranty and manufacturer's service support for the entire service life; wireless Bluetooth communication channel; Control unit and display of measurement results NTM-Terminal. single control unit; the ability to connect multiple meters to one control unit; ergonomic body and comfortable keyboard; high-resolution color display that provides a comfortable presentation of the results; ability to record measurement results; reference base of normative documentation. The meter is adapted to work in the control and analytical complex "NTM-EcoM". the possibility of monitoring the electromagnetic situation at the facilities; storage of measurement results in the NTM-EcoM program archive; analysis of the results obtained for compliance with current regulations; execution of the protocol of instrumental measurements
Produced in: Moscow
VOLTAMMETER PARMA VAF-A(M)
VOLTAMMETER PARMA VAF-A(M)
Scope of application · operational maintenance of relay protection circuits and power circuits of electrical installations · phasing during adjustment of differential protection, connection of current and voltage transformers, electric motors · control of the correct phasing of the connection accounting circuits · removal of the volt-ampere characteristic and measurement of angles · monitoring of single- and three-phase circuits in power supply cabinets · measurement of secondary (up to 10 A) and primary (up to 3000 A) currents with one device
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Mobile Laboratory For The Control Of Physical Factors
Mobile Laboratory For The Control Of Physical Factors
The companies NTM-Zashchita LLC (Moscow) and Avtospectr-NN (Nizhny Novgorod) have implemented a joint project "Mobile Laboratory for Physical Factors Control", which is a mobile complex equipped with the most modern equipment of well-known Russian and foreign manufacturers, designed to effectively solve the problems of sanitary and hygienic control and labor protection, certification of workplaces and monitoring of the production environment.
Produced in: Moscow
NTM-Terminal Control unit and display of measurement results
NTM-Terminal Control unit and display of measurement results
from 44 000 ₽
The NTM-Terminal block is a multifunctional device that allows you to choose: the necessary antenna-converter, operating mode, measurement procedure in relation to the object of examination, recording of measurement results.
Produced in: Moscow
Electromagnetic radiation level meter P3-100
Electromagnetic radiation level meter P3-100
Broadband electromagnetic radiation meters P3-100 (hereinafter referred to as meters P3-100) are designed for measurements energy flux densities (PPE) in the frequency range from 300 MHz to 40 GHz; electric field strength (NEP) from 9 kHz to 300 MHz; magnetic field strength (NEP) from 9 kHz to 50 MHz.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
INSULATION PARAMETER METER PARMA TENSOR-2
INSULATION PARAMETER METER PARMA TENSOR-2
PARMA TENSOR-2 (AC bridge) is designed for automatic measurements of: · capacitance and tangent of the dielectric loss angle of high-voltage insulation of capacitors, inputs, transformers using an external high-voltage capacitor, both in laboratory and in the "field" conditions · effective values of the first harmonic of the current and voltage of the industrial frequency · the angle of phase shift between the signals supplied to the inputs of the device · network frequencies * Measurements can be carried out according to the "straight" and "inverse" (inverted) scheme. * Allocates the vector of the influence current, which makes it possible to dispense with the phase regulator of the test voltage source or devices for compensating the influence current.
PARMA
Saint Petersburg
Produced in: Saint Petersburg