Diamond thermal cell NPVO with temperature controller
Diamond thermal cell NPVO with temperature controller
The sample heating system is designed to expand the capabilities of standard set-top boxes NPVO-ZDO and NPVO-A. It consists of a heated replaceable frame with a diamond prism and a temperature controller unit. For most solid samples in the heated state, it is possible to obtain a much more pronounced NPV spectrum than in the cold state. This makes it possible to increase the sensitivity of the method several times. The properties of some substances and compounds change dramatically with an increase in temperature, chemical interaction processes between components, their decomposition, oxidation in air, etc. may occur. If changes in the chemical composition of a substance occur during heating, a set of spectra corresponding to the kinetics of the process can be obtained with the help of an NPVO prefix with a diamond thermocell and a temperature controller, which is essential expands the possibilities of the method in research. Technical characteristics of the NPVO set-top box with a thermocell and a controller Transmission in the operating range of the spectrum, % of the input signal at least 10 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum dimensions of the solid sample, mm 0.5 × 0.5 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.3/1 The material of the crystal substrate is DIAMOND The diameter of the free zone of the crystal, mm not less than 2 x 3 The diameter of the focus spot, mm 1.5 Maximum temperature With 220o Adjustment accuracy, With 1o Time to reach the maximum temperature, min 10 Overall dimensions, mm 130×200×90 Weight, kg 1,2
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Single- and multi-pass gas cuvettes
Single- and multi-pass gas cuvettes
Single- and multi-pass flask are used for qualitative and quantitative spectral analysis of gas mixtures. The use of multi-pass flask makes it possible to confidently detect extremely small concentrations of the components of the gas under study (less than ppm units). • Three types of flask are supplied: 1. single-pass, having a stroke length of 100 mm, with a glass body and windows made of ZnSe, KBr, NaCl 2. multi-pass, with a beam stroke length of up to several tens of meters 3. multi-pass, with a beam stroke length of up to several tens of meters, equipped with a heating system of the working chamber up to 200 ° C and a thermal controller Multi-pass cuvettes have a transparent working chamber made of quartz glass; mirrors with a gold (99.999) coating provide a reflection coefficient in the IR region of at least 98%; additionally, cuvettes can be equipped with pressure and temperature sensors, fittings for controlling gas flow, etc.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
TWO-CHANNEL LABORATORY INSTALLATION
TWO-CHANNEL LABORATORY INSTALLATION
The bench laboratory unit is designed to test the adsorption properties of silica gels, protective layers and selective hydrogenation catalysts. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C; the power supply is a three- or single-phase AC network with a voltage of 220 V ± 10% with a frequency of 50 Hz. The average service life of the installation is 5 years. TECHNICAL CHARACTERISTICS Operating pressure range, 0.1-10 MPa Reactor operating temperature range, 0C 50÷600 The flow rate range of the pump forming the investigated raw material flow, ml/min 0.1-10 Volume of raw material capacity, l not less than 5 Operating temperature range of the raw material tank, 0C 30÷80 Operating temperature range of high and low pressure separators, 0C 30÷80 Flow range H2, mm/min 50÷3000 The maximum pressure at the outlet of the regulator is H2, MPa 10 Power consumption not more than, kW 6 Overall dimensions, mm 800×1300×2000 The operation mode is cyclic
Produced in: Yoshkar-Ola, Mari El
UNIVERSAL BENCH LABORATORY INSTALLATION FOR THE STUDY OF BASIC ORGANIC SYNTHESIS PROCESSES IN A REACTOR WITH A FIXED CATALYST LAYER
UNIVERSAL BENCH LABORATORY INSTALLATION FOR THE STUDY OF BASIC ORGANIC SYNTHESIS PROCESSES IN A REACTOR WITH A FIXED CATALYST LAYER
Monophase gas (the phase state of reagents at room temperature is liquid or gas). Monophase liquid (the phase state of reagents at room temperature is liquid). Two-phase (gas-liquid heterophase system). Temperature: operating range 500C – 6000C, 8000C.(three-zone heating furnace). Pressure: operating range 0.1 – 60, 100, 200 MPA. In the photo: A universal bench laboratory installation for the study of basic organic synthesis processes in a reactor with a fixed catalyst layer The unit is designed (tested) for the study of a wide range of heterogeneous catalytic reactions, including: Hydrogenation processes in the gas phase. Hydrogenation processes in the liquid phase. Gas-phase dehydration of aliphatic and aromatic alcohols. Dehydration of aromatic alcohols in the liquid phase. Alkylation of aromatic hydrocarbons with olefins and alcohols. Hydroalkylation of aromatic compounds with ketones. Dehydrogenation of chemical compounds of various classes.
Produced in: Yoshkar-Ola, Mari El
FT-801 IR Fourier spectrometer
FT-801 IR Fourier spectrometer
It is designed for recording absorption spectra of solid, liquid and gaseous substances in the near and middle IR region (including drugs, lacquers and paints, petroleum products, explosives, pharmacological preparations, polymer films and fibers) with their subsequent identification, as well as for qualitative and quantitative analysis of mixtures containing several components.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Optical set-top box for working with light-guide IR probes
Optical set-top box for working with light-guide IR probes
FT-801 IR Fourier spectrometers can additionally be equipped with a special optical set-top box that allows efficient use of light-guide systems. 4 types of light-guide probes allow measuring transmission and reflection spectra in solid, liquid and gaseous media Modern IR light guides have high intrinsic transmittance and sufficient mechanical strength, which makes it possible to transfer measurements from the laboratory directly to production - to control the flow of technological processes, check the quality of raw materials and finished products. Application areas: · Chemical and microbiological industry · Pharmaceutical industry · Medicine and Cosmetology · Food industry · Petroleum products, fuels and lubricants · Criminology
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Spectral measuring complex: automated IR Fourier spectrometer "FT-801" with IR microscope "MIKRAN-2"
Spectral measuring complex: automated IR Fourier spectrometer "FT-801" with IR microscope "MIKRAN-2"
2 supp.
from 100 500 ₽
The wide-range IR microscope of the MICRAN series, connected to the FT-801 and Infralum FT-801 Fourier spectrometers, is designed to study samples from 10 microns in size, including heterogeneous in composition. When working on an IR microscope, the operator has the opportunity to observe the object under study with a magnification of over 200X both using binoculars and on a monitor using a digital video camera, during photometry, select a local area of arbitrary shape with the help of diaphragms, and also “scan” the surface of the sample, observing the spectrum obtained in real time.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Mercury content indicator "SR-1"
Mercury content indicator "SR-1"
1 supp.
Technical specifications: The minimum limit of operation is 3×10-4 mg/m3 (the average daily MPC of a residential premises in accordance with GN 2.1.6.1338-03 of May 21, 2003) The range of set thresholds is from 3×10-4 mg/m3 to 1×10-3 mg/m3 Measurement time, no more than 15 s Output signals ON, READY, DANGEROUS, FAULTY Electrical parameters of the output signal 0-24 V, 0.5 A Operating mode Monitoring Average full service life of 5 years Frequency of maintenance 1 time in 3 months RS-232 digital output Power supply 190-240 V, 50 Hz Power consumption, no more than 30 watts Overall dimensions, no more than 280x420x600 mm Weight, not more than 18 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared Fourier spectrometer "InfraLUM® FT-08"
Infrared Fourier spectrometer "InfraLUM® FT-08"
1 supp.
Technical specifications: Operating spectral range, cm-1 from 400 to 7800 Spectral resolution, cm-1, not more than 0.7 The limit of the absolute error of the wavenumber scale, cm-1 ± 0.05 Signal-to-noise ratio (RMS) for the wavenumber 2150 cm-1, determined in the range ± 50 cm-1 for a resolution of 4 cm-1 and an accumulation time of 60 s, at least 40,000 The limit of deviation of the 100% transmission line from the nominal values for the wave number 2150 cm-1, determined in the range ± 50 cm-1, % ± 0.2 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system, % ± 0.25 The time of setting the operating mode of the spectrometers, h, no more than 2 Continuous operation time of spectrometers, h, not less than 8 Power consumption, In × A, not more than 65 Overall dimensions, mm, not more than 580x550x340 Weight, kg, not more than 32 Average time to failure, h, not less than 2500 Average service life of the spectrometer, years, at least 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
AUTOMATIC DIGITAL MULTI-CHANNEL PRESSURE MAINTENANCE SYSTEM IN THE VACUUM CHAMBER
The system includes a digital ionization-thermocouple vacuum meter with a continuous pressure measurement range, automatic degassing of sensors and a digital gas flow meter containing two or more built-in precision gas flow regulators, with thermometric gas flow meters, which allows the device to operate in the mode of autonomous intake of specified gas flow rates, regardless of the inlet pressure. The letters in the diagram show: А — electronic unit of vacuum gauge B — 220V power wire С — thermocouple lamp D — ionization lamp E — the electronic control unit of the leak valve G — signal cables H — cable for data exchange with IBM J — IBM L — cable for data exchange between the units M — cable for connecting additional devices to the network N,O — working gases inlet P,R — output of the working gases.
Produced in: Yoshkar-Ola, Mari El
Aluminum analyzer in water "FLUORATE® AA-2"
Aluminum analyzer in water "FLUORATE® AA-2"
1 supp.
Technical specifications: The range of detectable concentrations is 0.04-2 mg/l The temperature of the analyzed flow is from + 5 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W Dimensions 600x600x250 mm Weight Not more than 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 10,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Analyzer of sodium hypochlorite in water "AGH-3"
Analyzer of sodium hypochlorite in water "AGH-3"
1 supp.
Technical specifications: Output of results to digital display board, RS485, RS232; current loop 4-20 mA (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations is 20-200 g/l Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Relative humidity at + 25 °C 80 % Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +25 °C Ambient temperature from +5 to +35 °C Atmospheric pressure 87-107 kPa The warranty period of operation is 1 year Average service life of at least 3 years Dimensions - electronic block - optical unit no more than 300x400x150 mm no more than 120x90x90 mm Weight - electronic block - optical unit no more than 10 kg not more than 2 kg Power supply 187-242 V, 50 ± 1 Hz, from an autonomous source, 12V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg