Metolab 100 Rockwell Hardness Tester
Metolab 100 Rockwell Hardness Tester
METOLAB 100 is an analog stationary hardness tester with manual loading, designed to measure the hardness of various materials according to the Rockwell method, HRA, HRB and HRC scales, in accordance with current standards, equipped with an analog clock–type indicator. Structurally, the METOLAB 100 hardness tester is a stationary device consisting of a load application mechanism and the measuring unit itself. The principle of operation of the device is based on the indentation of a diamond cone or steel ball tip into the material under study, followed by measurement of the resulting print. Due to its ease of operation, the stationary METOLAB 100 hardness tester can find its application in a wide variety of industries and production, as well as in educational institutions of various levels in the training of specialists. The stationary METOLAB 100 Rockwell hardness tester is included in the State Register of Measuring Instruments of Russia (GRSI) and comes with a certificate of primary verification (on request). The number in the GRSI is 65128-16. Distinctive features of the stationary METOLAB 100 Rockwell hardness tester: Simple and convenient both in operation and maintenance; Wide range of measured values; High degree of reliability due to the absence of electronic components in the design of the hardness tester; The device operates without power. Basic delivery package: Stationary METOLAB 100 hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell hardness measures - 1 set; User Manual. Additional information: GOST standards and regulatory documents establishing requirements for the METOLAB 100 Rockwell hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements.
Metolab
Moscow
Produced in: Moscow
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
Electromagnetic flow meter Volga EM
Electromagnetic flow meter Volga EM
from 300 000 ₽
The Volga EM electromagnetic flowmeter is designed to measure the volumetric flow rate of drinking, natural, purified and waste water in pressure and non-pressure water pipelines. The device is designed specifically for use as part of commercial metering units and meets all the requirements for measuring equipment used for financial settlements of economic entities. The flow meter can be equipped with connecting fittings that allow the measuring sensor to be installed in a water duct with a non-pressure flow mode, for example, in a sewer collector (the so-called "L-system"). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters PP – full-pass primary converter PPM is a full–pass primary converter for low costs and installation in L-systems BP – mortise rod primary converter Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300 mm
Produced in: Moscow
Metolab 502 Vickers Hardness Tester
Metolab 502 Vickers Hardness Tester
The stationary METOLAB 502 hardness tester is a modification of the METOLAB 501 series device, equipped with a display and a digital micrometer that allows you to automatically read values without the need for conversion tables. The device also automatically calculates the hardness of the samples. The METOLAB 502 microhardometer is designed to measure the hardness of various samples and products (steels, cast iron, non-ferrous metals and soft alloys) according to the Vickers (HV) and Knup (HK) scales in full compliance with GOST R ISO 6507-1-2007. The device has high accuracy, performs measurements in a wide range and with high repeatability. The stationary automatic METOLAB 502 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 502 Micro-Vickers hardness tester: Built-in digital micrometer that allows you to automatically read readings without the need for translation tables; Automatic hardness calculation; Simple and intuitive control of the device, fully Russified menu; Wide range of measured values – from 5 to 2500 HV; A wide range of applied test loads - 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Large and bright LCD display. Basic delivery package: Stationary METOLAB 502 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow
Chromatograph Milichrome A-02
Chromatograph Milichrome A-02
Overall dimensions: 550x230x350 mm Weight (without computer): ~17 kg Power consumption: up to 200 watts Warranty service : 1 year   Detector Two-beam spectrophotometer Spectral range – 190-360 nm Simultaneous detection at 1-8 wavelengths Cell volume – 1.2 µl Noise <0.0001 E.O.P. at 250 nm Drift <0.00005 E.O.P./hour at 250 nm Column Ø2x75 mm stainless steel The efficiency of the column is up to 6000 theoretical plates Thermostat Solid-state electric Set temperature from 35 to 90°C The discreteness of the temperature setting is 1 °C Temperature control error ±0.3°C      Pump Two-pronged, gradient The feed rate is from 5 to 1000 µl/min, the maximum pressure is 70 atm . The gradient is formed from 1 to 20 linear sections Automatic doser Automatic, programmable Number of test tubes – 46 The number of analyses in the series is from 1 to 200 The dosed volume is from 1 to 99 µl Test tubes made of glass with a volume of 200 µl Polyethylene tube stoppers Software OS: Windows® XP/7/10 Milichrome A-02™, Multichrome™, Alphachrome, Alphaspectrum
EkoNova
Novosibirsk
Produced in: Novosibirsk
Universal Metolab 701 Hardness Tester
Universal Metolab 701 Hardness Tester
METOLAB 701 is a stationary universal hardness tester that allows you to control these parameters according to the Brinell, Rockwell (A, B and C) and Vickers scales. The device has an electromechanical drive for applying and removing the main load, and is also equipped with a small LCD indicator that displays the exposure time. The main indicator of the device is analog, clock type. Also, the METOLAB 701 hardness tester is equipped with a measuring microscope with illumination. The stationary universal METOLAB 701 hardness tester is designed to measure the hardness of various materials and products (steels, cast iron, non-ferrous metals, soft alloys, etc.) according to the Brinell, Rockwell, Vickers scales. Distinctive features of the stationary universal METOLAB 701 hardness tester: Scales for Rockwell measurements: HRA, HRB, HRC; Scales for Brinell measurements: HBW2.5/31.25, HBW2.5/62.5, HBW5/62.5, HBW2.5/187.5, HBW 10/100, HBW 1/30; Vickers measuring scales: HV30, HV100; Easy to manage and maintain, low cost of measurements; Electromechanical drive for application and removal of load; Analog clock type indicator; Built-in microscope with two additional 2.5 and 5x lenses and backlight. Basic delivery package: Stationary universal METOLAB 701; Conical diamond Rockwell indenter (120° angle) - 1 pc.; Vickers diamond indenter (136° angle) - 1 pc.; Indenter with 1.5875 mm ball - 1 pc.; Indenter with 2.5mm ball - 1 pc.; Indenter with 5.0 mm ball - 1 pc.; Large flat table 150 mm - 1 pc.; Medium flat table 60 mm - 1 pc.; V-shaped table 40 mm - 1 pc.; Hardness measures - 1 set; 15x microscope - 1 pc.; 2.5x lens - 1 pc.; 5.0x lens - 1 pc.; User Manual.
Metolab
Moscow
Produced in: Moscow
Metolab 501 Vickers Hardness Tester
Metolab 501 Vickers Hardness Tester
METOLAB 501 is a stationary hardness tester using the Micro-Vickers method, on the HV scale, as well as on the Knoop – HK scale. The device allows you to determine the hardness of various products (steel, cast iron, non-ferrous metals and soft alloys) in full compliance with GOST R ISO 6507-1-2007. The METOLAB 501 hardness tester has high accuracy, a wide measurement range (5-2500 HV), is equipped with a vernier micrometer, and also allows you to apply a wide range of loads in the range from 10 to 1000 gr. The principle of operation of the METOLAB 501 hardness tester is based on the indentation of a pyramidal diamond indenter with a certain force into the controlled surface of the sample. After the designated time, the indenter rises. The hardness value is calculated according to the diagonal of the print (depth), or calculated by the formula. Stationary automatic METOLAB 501 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 501 Micro-Vickers hardness tester: Simple and intuitive interface in Russian; Wide range of measured values – from 5 to 2500 HV; Wide range of test loads with manual switching – 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Bright and clear LCD display that displays all the necessary information (set load, exposure time, test mode); Manual input of the diagonal length using a membrane keyboard; Vernier micrometer. Basic delivery package: Stationary METOLAB 501 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow