Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Technical specifications: Melt flow rate for 10 min, g 0,1 - 99,9 The dimensions of the capillary opening, mm dia. 2,095 diam. 1,048 (optional) diam. 1,180 (optional) Set of loads, kg 0,325-5 10-21,6(optional) Temperature range in the working chamber, °C +50...+450 Accuracy of temperature maintenance, °C: - in the range of 50...300 °C: ± 0.1 - in the range of 300...350 ° C: ± 0.2 - in the range of 350...450°C: ±0.3 The discreteness of setting the temperature of the chamber, ° C 1 Time to enter the operating mode, no more, min 40 Power supply, V/kW 220/0.8 Installation dimensions, WxDxH mm 513x445x590 (920 – Maximum height with a fully loaded polymer chamber and a full stack of loads with a handle for their installation) Installation weight, not more than 70 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
M532 Raman microscope by Spektr-M
M532 Raman microscope by Spektr-M
1 supp.
The M532® Raman microscope combines the capabilities of the Inspectr R532® Portable Raman Express Analyzer and the U300M microscope, adapting it for both transmission and reflection measurements. The wide functionality of the M532 microscope makes it possible to find and analyze individual particles with a size of 2-3 µm among many similar ones with similar physical and chemical properties, which opens up new research opportunities within the framework of a single Raman system. A spatial resolution of 1 µm and a spectral resolution of 4-6 cm-1 ensure excellent measurement accuracy and reproducibility. The compact design and portability of the instrument allow for high-quality and instant analysis of substances without sample preparation, which makes the M532 microscope an indispensable instrument for a wide range of studies. Equipped with a motorized slide (optional) with a step of 0.36 µm, the M532 microscope scans the surface of the sample, recognizes substances in multi-component heterogeneous mixtures and creates a graphical image of the intensities of Raman scattering characteristic lines at various points on the surface (2D mapping), which makes the M532 microscope the most advantageous in terms of price-quality ratio scanning Raman microscope in the world market.
Spektr-M
Chernogolovka
Produced in: Chernogolovka, Moscow region
 Atomic Emission Complex "Grand Globula"
Atomic Emission Complex "Grand Globula"
Atomic Emission Complex "Grand Globula" includes a spectrometer "Grand", a spectroanalytic generator "Ball Lightning" and a tripod "Globula". It allows the analysis of various substances and materials in arc and spark discharges in air, for example according to GOST 17818.15-90 "Graphite. Spectral analysis method", GOST 9717.1-82 "Copper. A method of spectral analysis based on metallic standard samples with photoelectric spectrum registration" and other MVIS.
Produced in: Novosibirsk
Atomic emission spectrometer Iskroline 500
Atomic emission spectrometer Iskroline 500
1 supp.
The main advantage of a mobile spectrometer is the ability to measure the composition of alloys not only in the laboratory on specially prepared samples, but also directly in a workshop or warehouse without cutting the product or workpiece.
Iskrolajn
Saint Petersburg
Produced in: Saint Petersburg
Membrane nitrogen plants
Membrane nitrogen plants
A membrane nitrogen plant is a set of special equipment designed to produce nitrogen from atmospheric air by the method of membrane separation at a pressure of up to 25 bar. The production of nitrogen in this technological process is based on the principle of separation of gas mixtures in a membrane module, due to the different penetration rates of the components of the gas mixture through polymer membranes and the differential partial pressures on both sides. In the case of separation of the air mixture, oxygen has a greater permeability than nitrogen. The difficult-to-penetrate gas components (N2, CH4, CO) pass along the entire length of the generator and then come to the consumer. The output is a gas mixture with an N2 content of up to 99.9%. The membrane installation allows to obtain high-pressure production gas (nitrogen). The composition of a standard membrane nitrogen production plant: Air compressor; Dehumidifier; Main filter block, including coal column; Air receiver; Membrane generator; Production gas receiver.
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Adsorption nitrogen plant
Adsorption nitrogen plant
Adsorption nitrogen plant is a set of equipment for the production of nitrogen from atmospheric air by short–cycle heat-free adsorption at a pressure of up to 13 bar. The adsorption nitrogen plants of the Provita company allow to produce nitrogen with a purity of up to 99.9999%. The capacity of the plants ranges from several liters per minute to hundreds of cubic meters per hour. The basis of the installations are nitrogen adsorption generators developed and manufactured by our company. A carbon molecular sieve with a developed microporous structure is used as an adsorbent. The gas generator requires dry compressed air with a pressure of at least 6 bar to operate, so the installation includes an air compressor, as well as a dehumidifier and an air receiver (if they are not part of the compressor). The source air must be cleaned of dust and oil, which is carried out by the main filters included in the installation or directly by the nitrogen generator. The nitrogen receiver is used for the accumulation of production gas.
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-150S
Laboratory scales VLTE-150S
from 67 490 ₽
Technical characteristics: NIP, G150 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 150g incl. ±10 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Two-jet arc plasmatron "Torch"
Two-jet arc plasmatron "Torch"
The plasmatron is designed for direct atomic emission spectral analysis of powder samples. The excitation of atoms occurs in a DC argon arc plasma. Weak matrix effects and low detection limits make it possible to use this excitation source for the analysis of various samples, both with mineral and organic matrix.
Produced in: Novosibirsk
Sulfur and Nitrogen Analyzer SPECTROSCAN META
Sulfur and Nitrogen Analyzer SPECTROSCAN META
The analyzer allows you to determine the content of sulfur and nitrogen in oil and petroleum products (diesel fuel, gasoline, kerosene, gas oil and any distillate petroleum products), hydrocarbon gas, liquefied petroleum gas (LPG), natural gas, liquefied natural gas (LNG), chemical synthesis products, biological materials by ultraviolet fluorescence and chemiluminescence. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The analyzer is designed to determine: - mass fraction of sulfur in accordance with GOST ISO 20846-2016, GOST 34712-2021, GOST R 56866-2016, GOST 34237-2017, ASTM D5453-19, ASTM D6667-21, ASTM D7551-15, ISO 20729-17 ; - the mass fraction of nitrogen in accordance with ASTM D4629-17. A wide range of concentrations: from ultra-low to high. Modular principle: Each detector is a separate module. The device is equipped individually for each specific task. The possibility of simultaneous determination of sulfur and nitrogen in the analysis process. The principle of operation of the analyzer is to burn the test sample in an oxygen-enriched atmosphere or air at a temperature of 1050 ° C. The sulfur dioxide (SO2) and nitrogen oxide (NO) formed during combustion are transferred by carrier gas to the detection units with preliminary removal of water vapor, on the desiccant, and soot, on the filter. Determination of sulfur is carried out by ultraviolet fluorescence. Determination of nitrogen by chemiluminescence.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Electric arc installation for the analysis of powder samples by the method of spillage injection "Stream"
Electric arc installation for the analysis of powder samples by the method of spillage injection "Stream"
The installation is designed to excite atomic emission spectra of powder samples in an electric arc by the spillage-injection method. It provides high performance of routine analyses, has a low consumption of graphite electrodes and is used in conjunction with any spectral devices – "Grand", STE-1, DFS-458, MFS-8, PGS-2, etc.
Produced in: Novosibirsk
Grand Expert Vacuum Spectrometer
Grand Expert Vacuum Spectrometer
Vacuum spectrometers are designed for rapid analysis of alloys based on iron, copper, aluminum and other metals in factory and research laboratories, including the determination of elements having analytical lines in the field of vacuum ultraviolet (VUV) (for example, S, P and C in steels).
Produced in: Novosibirsk