Search

885 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 262
    Names
    Loading...
  • 73
    Manufacturer
    Loading...
  • 40
    Made in
    Loading...
  • 66
    Additional
    Loading...
View:
885 products
Nitrogen Generator GA-1200
Nitrogen Generator GA-1200
from 492 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.0 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 1.0 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 7 ati is at least 1380 l/h (23 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Minimum inlet air pressure is 7 ati Maximum allowable inlet air pressure is 8.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 150 l/min Power consumption is not more than 200 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 38 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-18-K
Pure nitrogen generator GCHA-18-K
from 396 000 ₽
The characteristics of the device are similar to the GCHA-18 model; the difference is that the oil–free compressor built into the GCHA-18-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor-12 months from the date of sale.
Produced in: Moscow
Manual mechanical press
Manual mechanical press
Designed for the preparation of samples in the form of compressed tablets with a diameter of 3.5 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the device is based on creating the pressure necessary for pressing due to a mechanical lever system - the press is made of high-quality alloy hardened steel - for the manufacture of a tablet with a diameter of 3.5 mm, a minimum amount of the test substance and KBr is required - for the study of finished samples on a Fourier spectrometer, a vertical or horizontal microfocusing prefix is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Diamond thermal cell NPVO with temperature controller
Diamond thermal cell NPVO with temperature controller
The sample heating system is designed to expand the capabilities of standard set-top boxes NPVO-ZDO and NPVO-A. It consists of a heated replaceable frame with a diamond prism and a temperature controller unit. For most solid samples in the heated state, it is possible to obtain a much more pronounced NPV spectrum than in the cold state. This makes it possible to increase the sensitivity of the method several times. The properties of some substances and compounds change dramatically with an increase in temperature, chemical interaction processes between components, their decomposition, oxidation in air, etc. may occur. If changes in the chemical composition of a substance occur during heating, a set of spectra corresponding to the kinetics of the process can be obtained with the help of an NPVO prefix with a diamond thermocell and a temperature controller, which is essential expands the possibilities of the method in research. Technical characteristics of the NPVO set-top box with a thermocell and a controller Transmission in the operating range of the spectrum, % of the input signal at least 10 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum dimensions of the solid sample, mm 0.5 × 0.5 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.3/1 The material of the crystal substrate is DIAMOND The diameter of the free zone of the crystal, mm not less than 2 x 3 The diameter of the focus spot, mm 1.5 Maximum temperature With 220o Adjustment accuracy, With 1o Time to reach the maximum temperature, min 10 Overall dimensions, mm 130×200×90 Weight, kg 1,2
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Hydrogen Generators GVCH-6
Hydrogen Generators GVCH-6
from 126 000 ₽
The GVCH-6 hydrogen generators are designed to power flame ionization detectors. They are equipped with a four-stage gas purification system. The hydrogen capacity is 6 liters/hour (100 ml/min). They have smooth adjustment and digital indication of the output pressure. Technical specifications The brand of produced hydrogen "A" according to GOST 3022-80 Purity of hydrogen in terms of dry gas is about 99.995% The concentration of water vapor at 20 ° C and 1.0 ati is not more than 20 ppm Total hydrogen capacity reduced to normal conditions is 6 l/h The range of the specified output pressure of hydrogen is from 1.5 to 6.0 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode is no more than 30 min Volume of bidistilled water to be filled is 1 l Consumption of bidistilled water is no more thann 0.01 l/hour Consumption of bidistilled water is 1.6 g/l of hydrogen Average power consumption in stationary mode is no more than 100 VA Maximum power consumption (at startup) is no more than 150 VA Overall dimensions of the generator, (width x depth x height) are not more than 180x450x435 mm The mass of the generator is not more than 11 kg Working conditions: ambient temperature, °C from +10 to +35 Power supply from single-phase mains: AC voltage, 220±10% and frequency, Hz 50 ± 1
Produced in: Moscow
UNIVERSAL BENCH LABORATORY INSTALLATION FOR THE STUDY OF BASIC ORGANIC SYNTHESIS PROCESSES IN A REACTOR WITH A FIXED CATALYST LAYER
UNIVERSAL BENCH LABORATORY INSTALLATION FOR THE STUDY OF BASIC ORGANIC SYNTHESIS PROCESSES IN A REACTOR WITH A FIXED CATALYST LAYER
Monophase gas (the phase state of reagents at room temperature is liquid or gas). Monophase liquid (the phase state of reagents at room temperature is liquid). Two-phase (gas-liquid heterophase system). Temperature: operating range 500C – 6000C, 8000C.(three-zone heating furnace). Pressure: operating range 0.1 – 60, 100, 200 MPA. In the photo: A universal bench laboratory installation for the study of basic organic synthesis processes in a reactor with a fixed catalyst layer The unit is designed (tested) for the study of a wide range of heterogeneous catalytic reactions, including: Hydrogenation processes in the gas phase. Hydrogenation processes in the liquid phase. Gas-phase dehydration of aliphatic and aromatic alcohols. Dehydration of aromatic alcohols in the liquid phase. Alkylation of aromatic hydrocarbons with olefins and alcohols. Hydroalkylation of aromatic compounds with ketones. Dehydrogenation of chemical compounds of various classes.
Produced in: Yoshkar-Ola, Mari El
GEYSER-2A DEVICE
GEYSER-2A DEVICE
The Geyser –2A measuring and computing complex is designed to determine the dynamic characteristics and energy efficiency (caloric content) of various substances, including special products (gunpowder, explosives). The device also allows you to determine the chemical resistance of substances by the delay of the ignition time. The analysis is carried out in a given volume in the isothermal mode or in the temperature programming mode. technical specifications Operating temperature range in the reactor, from +50 to +600 ° C. The programming speed of the thermostat temperature in the operating temperature range, no more than 10 ° C. The limit of the permissible absolute error of setting the temperature of temperature control, no more than ± 2 ° C. Instability of maintaining the set temperature in the thermostat for 10 minutes, no more than ± 0.1 ° C. Sampling rate of the optical recording system, at least 25kHz The range of measurement of the ignition delay time in the isothermal mode, from 0 to 600 seconds. The measurement range of dynamic characteristics in the temperature programming mode, from 0 to 3600 sec. The continuous operation time of the device is at least 24 hours. The time for the device to enter the mode from the moment it is turned on, no more than 0.2 hours. The device is powered by AC 220V,+10/-15%,(50±1) Hz. The power consumption of the device, no more than 200 watts. The weight of the device without packaging, no more than 7 kg. Overall dimensions (width × depth × height), no more than 330×265×170 mm.
Produced in: Yoshkar-Ola, Mari El
TWO-CHANNEL LABORATORY INSTALLATION
TWO-CHANNEL LABORATORY INSTALLATION
The bench laboratory unit is designed to test the adsorption properties of silica gels, protective layers and selective hydrogenation catalysts. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C; the power supply is a three- or single-phase AC network with a voltage of 220 V ± 10% with a frequency of 50 Hz. The average service life of the installation is 5 years. TECHNICAL CHARACTERISTICS Operating pressure range, 0.1-10 MPa Reactor operating temperature range, 0C 50÷600 The flow rate range of the pump forming the investigated raw material flow, ml/min 0.1-10 Volume of raw material capacity, l not less than 5 Operating temperature range of the raw material tank, 0C 30÷80 Operating temperature range of high and low pressure separators, 0C 30÷80 Flow range H2, mm/min 50÷3000 The maximum pressure at the outlet of the regulator is H2, MPa 10 Power consumption not more than, kW 6 Overall dimensions, mm 800×1300×2000 The operation mode is cyclic
Produced in: Yoshkar-Ola, Mari El
MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
The measuring and computing complex "Vulkan-2005M" and "Vulkan-2005M1 Vacuum Tester" are designed to measure the pressure of vapors and gases in a given volume when determining the thermal stability of substances in the isothermal mode, carried out according to the certified methodology of the customer, developed specifically for each substance. The CPI is included in the State Register of Measuring Instruments. technical specifications The measurement range of barometric pressure is from 86.6 kPa to 106.7 kPa. The absolute pressure measurement range should be from 5 kPa to (Ratm. +250) kPa, where Ratm. – atmospheric pressure. The limit of permissible error of pressure measurement does not exceed the values of: – barometric - ± 0.5 kPa. – overpressure - ± 2.0 kPa. – total (barometric + excessive) - ± 2.5 kPa. The temperature range in the reaction volumes of primary converters is from +50 to +280 °With the use of reusable fluoroplastic gaskets, from 280 to 400℃ with the use of disposable aluminum gaskets. Instability of maintaining the set temperature in thermostats for 10 minutes no more than ± 0.1 ° C. The discreteness of setting the temperature of temperature control is 0.1 ° C. The error of setting the temperature of temperature control does not exceed ± 2 ° C. The total volume of the glass is 20 ml. Minimum vacuum: 5 kPa. The IVC consists of up to 4 thermostats with primary converters, 8 in each thermostat. The time interval between measurement cycles in automatic mode is 1 second. The emergency protection is triggered when the values, pressure or temperature set in the control program are exceeded. The hardware overheat protection of the thermostat is triggered when the maximum operating temperature of the complex is exceeded. The IVC is powered from an AC mains voltage of 220V with an acceptable deviation from minus 15% to +10% frequency (50 + 1) Hz with a coefficient of nonlinear distortion of no more than 5%. The output time of the thermostats to the mode from the moment they are turned on does not exceed 3.5 hours. The power consumption of the CPI, no more than 4 kW. Overall dimensions of one thermostat, (width × depth × height), no more than -450×460×600mm. The weight of one thermostat, no more than 32 kg. The continuous operation time of the CPI is at least 72 hours.
Produced in: Yoshkar-Ola, Mari El
AUTOMATIC SIX-CHANNEL INSTALLATION
AUTOMATIC SIX-CHANNEL INSTALLATION
The unit is designed for testing fresh catalysts, deactivated in laboratory conditions and equilibrium (used in industry). The volume of the loaded catalyst is from 5 to 12 grams, the loading of raw materials (vacuum gas oil) is 1-3 grams. Conradson coking capacity should not exceed 10%. After cracking, the degree of coking of the catalyst is determined directly at the installation. Liquid and gaseous cracking products are analyzed by three gas chromatographs with automatic dispensers, which makes it possible to determine the degree of conversion and selectivity of the catalyst.
Produced in: Yoshkar-Ola, Mari El
Universal set-top box of NPVO and ZDO with a diamond element and a built-in mini-monitor
Universal set-top box of NPVO and ZDO with a diamond element and a built-in mini-monitor
It is designed for measurement by the method of disturbed total internal reflection with simultaneous visualization of a micro-object on an integrated and external monitor, as well as by the method of mirror-diffuse reflection with an angle of incidence of 45o at the upper location of the sample. The prefix in the mode of a single NIP is used to register absorption spectra: liquids of any degree of viscosity (solutions, suspensions, oils, etc.), including those with high chemical activity; solid objects of arbitrary shape, including samples with very high hardness (any polymers, fragments of paint coatings, etc.); powdery substances, including powders with very high hardness (drugs, pharmaceuticals, explosives, inorganic compounds); samples in the form of thin tapes; samples in the form of fibers. The maximum hardness and chemical resistance of the diamond significantly expand the possibilities of the method; there is no need for periodic replacement of the crystal. The set-top box allows you to register spectra without time–consuming sample preparation, and the presence of a visual inspection system of the studied surface with a high-quality video camera and a built-in high-definition mini-monitor increases efficiency when working with small samples - fragments of thin fibers, microparticles, etc. The built-in monitor has the functions of digital 10X zoom, inverting, etc. The image can be simultaneously displayed on the computer screen (using a USB interface) and then saved as a file. The removable flange provides a quick and convenient sample change and cleaning of the crystal surface. The design with a diamond element protruding above the base plane of the NPVO allows you to study samples with sufficiently large overall dimensions. The high quality and repeatability of the results is achieved due to the absence of the influence of the thickness of the substance layer on the shape of the spectrum and the intensity of the absorption bands. The sample retains its original physicochemical properties and, if necessary, can be further investigated by other methods. The universal attachment clamp is equipped with a precision lever mechanism for quickly lowering the tip and a micrometer screw that allows you to pre–set the optimal degree of pressure - this ensures quick sample change and repeatability of the results during measurements. For convenience when working with liquid and paste-like samples, as well as in the ZDO mode, it is possible to rotate the clamping console by 180o. The console is equipped with two replaceable tips – with a spherical working part and with a flat hinged head. The high hardness of the diamond allows the use of large clamping forces, which is the determining factor for obtaining high-quality spectra. A replacement table is used to register the specular and diffuse reflection spectra. The sample is located on the subject plane of the investigated surface downwards. The method is used to determine the spectral characteristics of optical parts, thin tapes on the surface, crystals, and other large solid objects of arbitrary shape and size.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
DIGITAL MULTICHANNEL LEAK
DIGITAL MULTICHANNEL LEAK
The Meta-chrome digital gas flow meter is designed to maintain a given pressure and the ratio of the amount of gases (in the flow mode) or gas flow (in the intake mode) in vacuum installations with automatic and manual control. technical specifications The number of control channels is 2 (or more on request). The maximum flow rate for each of the channels is 700 cm3/min. The possibility of using gas correction coefficients, the most commonly used gases are listed in the leaker database. The accuracy of maintaining a given proportion of gases is 5%. The accuracy of maintaining the specified gas flow rates is 3%. Input pressures from 1 to 4 atm. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption (without a personal computer), no more than — 30 VA. Overall dimensions (width × depth × height), no more than 165×350×215 mm. Weight, not more than 5.5 kg.
Produced in: Yoshkar-Ola, Mari El