Search

73 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 68
    Names
    Loading...
  • 20
    Manufacturer
    Loading...
  • 21
    Made in
    Loading...
  • 37
    Additional
    Loading...
View:
73 products
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
Optical imaging system for fluorescence and luminescence in LumoTrace® biological samples: LumoTrace® Lite model (bioluminescence)
The lowest cost and most compact version of the LumoTrace® Optical Imaging System manufactured by Abisens LLC for sensitive bioluminescence detection. The compactness and low price of the LumoTrace®Lite imaging system are due to the fact that it allows only bioluminescence to be recorded (older models, in addition to bioluminescence, allow fluorescence to be recorded, and are also modular, which provides them with the opportunity to upgrade). Despite its compactness and relatively low price, this model is equipped with a new highly sensitive digital camera HICMOS manufactured by Abisens LLC, which allows recording ultra-small amounts of phosphor both in laboratory animals in vivo and in vitro experiments. The device is an indispensable tool for conducting preclinical studies on the way to the introduction of advanced drugs, in the implementation of non-invasive monitoring of the development of socially significant diseases, monitoring the effectiveness of immuno- and gene therapy,
Abisens
Sirius
Produced in: Krasnodar region
The film for PCR tablet, adhesive 142 * 80 mm.
The film for PCR tablet, adhesive 142 * 80 mm.
from 3 500 ₽
PCR film, adhesive. High optical transparency. Low autofluorescence Hydrophobic adhesive is resistant to turbidity. Low level of extractable substances in various solvents. The film is similar in all its characteristics to imported samples. Recommendations for use: The best sealing results are achieved when using an applicator or roller. Perforation is applied. Temperature range: -20°C + 120°C Material: PET Packaging: 100 sheets
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Chromatograph Milichrome A-02
Chromatograph Milichrome A-02
Overall dimensions: 550x230x350 mm Weight (without computer): ~17 kg Power consumption: up to 200 watts Warranty service : 1 year   Detector Two-beam spectrophotometer Spectral range – 190-360 nm Simultaneous detection at 1-8 wavelengths Cell volume – 1.2 µl Noise <0.0001 E.O.P. at 250 nm Drift <0.00005 E.O.P./hour at 250 nm Column Ø2x75 mm stainless steel The efficiency of the column is up to 6000 theoretical plates Thermostat Solid-state electric Set temperature from 35 to 90°C The discreteness of the temperature setting is 1 °C Temperature control error ±0.3°C      Pump Two-pronged, gradient The feed rate is from 5 to 1000 µl/min, the maximum pressure is 70 atm . The gradient is formed from 1 to 20 linear sections Automatic doser Automatic, programmable Number of test tubes – 46 The number of analyses in the series is from 1 to 200 The dosed volume is from 1 to 99 µl Test tubes made of glass with a volume of 200 µl Polyethylene tube stoppers Software OS: Windows® XP/7/10 Milichrome A-02™, Multichrome™, Alphachrome, Alphaspectrum
EkoNova
Novosibirsk
Produced in: Novosibirsk
Laboratory hydrocracking/gasification unit
Laboratory hydrocracking/gasification unit
The laboratory unit is designed to study the catalytic and thermal processes of processing heavy petroleum raw materials. The installation allows you to explore the following processes: 1. Hydrocracking 2. Thermal cracking 3. Gasification of water dispersions of coal, biomass, heavy oil residues. The high-pressure liquid pump operates at temperatures up to 200°C, which makes it possible to supply high-viscosity components (fuel oil, tar, paraffin, ceresin, etc.) to the reactor. The laboratory unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. The modular configuration of the unit allows you to change or upgrade it at any time for new tasks. Main advantages: 1. The possibility of developing and supplying a reactor to meet customer requirements; 2. A wide range of accessories for the supply of liquids/solids; 3. Visual process control; 4. A system of control and regulation of technological parameters; 5. Convenience of loading and unloading of raw materials and reaction products; 6. The possibility of conducting long-term tests in continuous mode; 7. The possibility of upgrading the structure for new purposes; 8. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
Thermostat for determining oxidative stability LT-830
Thermostat for determining oxidative stability LT-830
Design features: Microprocessor-based PID controller; Multifunctional control knob; Minimum temperature gradient over the entire volume of the bath; Hole for the control thermometer; Stainless steel bathtub ; Built-in cooling heat exchanger; Self-diagnosis system; A faucet for draining the working fluid. Technical specifications: Temperature range, °C - without external cooling - with cooling with tap water (current +10)...+100 (Tvods+5)...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of test places 4 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 30 Working fluid - up to 80 °C - above 80 °C distilled water water-glycerin mixture Overall dimensions (WxDxH), mm 560x250x710 Weight of the device without liquid, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Technical specifications: The volume of the analyzed sample is 5 ml The volume of the test chamber is 25 ml Test temperature 37.8°C Accuracy of maintaining the temperature of the chamber ±0.1 °C Pressure measurement range 0.01...200 kPa Pressure measurement accuracy ±0.01 kPa Gas/liquid ratio 4/1 Power consumption from 220 mains, no more than 150 watts USB, LAN interface Overall dimensions, no more 450x230x190 mm Weight, not more than 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
“KELTRUN” unit for the determination of nitrogen and protein mass fraction by Kjeldahl method by Sibagropribor
“KELTRUN” unit for the determination of nitrogen and protein mass fraction by Kjeldahl method by Sibagropribor
from 437 000 ₽
The Kjeldahl method is one of the most accurate methods for determining nitrogen and protein in a wide group of products, but, unfortunately, it has a number of significant drawbacks - these are low speed, a large number of possible losses during the analysis, bulky equipment, and the use of aggressive reagents. Sibagropribor Holding presents KELTRUN (KELTRUN) - a set of equipment for carrying out a complete analytical cycle according to the Kjeldahl method, which will allow: • to increase the speed of analyzes (high speed of distillation and ashing, simultaneous processing of several samples); • ensure the safety of personnel (high quality of reaction vessels, effective absorption of acid vapors by the exhaust system, additional protection of personnel in emergency situations); • reduce possible losses in the analysis process; • improve the reproducibility of results. «KELTRAN» (KELTRUN) will allow you to determine nitrogen / protein in the widest list of substances: • food products: dairy, cereals, meat, cereals, etc.; • feed and compound feed; • fertilizers; • water, drinks, beer; • soil, bottom sediments, sediment samples, activated sludge; • crude oil, lubricants; • various chemicals; • alcohol content in wines, musts and spirits; • etc. The set of equipment «KELTRAN» (KELTRUN) allows you to analyze according to GOST and determine the nitrogen content in the range of 0.02 - 99.00%. Composition of the complex «KELTRAN» (KELTRUN): - Digestor; - Distiller; - Scrubber (*not included in the price of the complex); - Titration unit: manual, semi-automatic or automatic (*not included in the price of the complex); Warranty - 1 year. Important feature! In many distillers (made in China and others), when used, alkali passes through a valve-type pump, with a low production resource (sometimes the resource is enough for only 3 months). In the distiller of our production, the alkali passes through a RELIABLE PERISTALTIC PUMP, this ensures a long service life of the distiller! Package options Cost (including VAT): Digestor, Distiller, Water jet pump 379,400 rubles; Digestor, Distiller, Water jet pump, Scrubber 434,700 rubles; Digestor, Distiller, Water jet pump, Manual titration unit 396,900 rubles; Digestor, Distiller, Water jet pump, Scrubber, Manual titration unit 452,200 rubles; Digestor, Distiller, Water jet pump, Kit «Titrion-pH» (c2) 605,400 rubles; Digestor, Distiller, Water jet pump, Scrubber, «Titrion-pH» kit (c2) 660,700 rubles.
SIBAGROPRIBOR
Krasnoobsk
Produced in: Novosibirsk region, Krasnoobsk
Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Installation for determining the melt flow index of thermoplastics PTR-LAB-02
Technical specifications: Melt flow rate for 10 min, g 0,1 - 99,9 The dimensions of the capillary opening, mm dia. 2,095 diam. 1,048 (optional) diam. 1,180 (optional) Set of loads, kg 0,325-5 10-21,6(optional) Temperature range in the working chamber, °C +50...+450 Accuracy of temperature maintenance, °C: - in the range of 50...300 °C: ± 0.1 - in the range of 300...350 ° C: ± 0.2 - in the range of 350...450°C: ±0.3 The discreteness of setting the temperature of the chamber, ° C 1 Time to enter the operating mode, no more, min 40 Power supply, V/kW 220/0.8 Installation dimensions, WxDxH mm 513x445x590 (920 – Maximum height with a fully loaded polymer chamber and a full stack of loads with a handle for their installation) Installation weight, not more than 70 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Adhesive film for EIA microplate 130*90 mm
Adhesive film for EIA microplate 130*90 mm
from 1 200 ₽
Adhesive Film for EIA tablets is produced for standard studies. Non-sterile. Optically transparent. The film securely seals the tablet. Moisture-proof, non-toxic, prevents excessive evaporation of water from the wells of the microplate, sedimentation of reagents on their walls, and as a result, the edge effect. Prevents false positive results during EIA. A convenient configuration allows you to cut and detach the film according to the number of holes used in one analysis statement. There is 1 notch in width and 1 notch in length. Thickness: 80 microns. Size:130*90mm Composition: PVC Application temperature: -40°C to +80°C Color: Transparent Packaging: 100 pcs.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Adhesive sealing films for PCR (separable)
Adhesive sealing films for PCR (separable)
from 12 000 ₽
Adhesive sealing films for PCR (separable) Material: PET, pharmaceutical grade glue, no pollution. Absence of DNase, RNase, DNA, endotoxin, PCR inhibitor and contamination of the heat source. Product advantage: The film can be used as a whole or divided into 8 strips for use. Product Usage: Suitable for quantitative fluorescence detection by PCR. High optical transparency, no spontaneous fluorescence. Size: 128*99 mm. Temperature range: -20+120 °C Packing: 50 pieces.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
The parameters of accuracy, convergence and reproducibility are equivalent and correspond to the results obtained in accordance with the methods of ASTM D2500, ASTM D 97, GOST 20287 (methods A and B), GOST 5066 (for the determination of turbidity), GOST 5950, EN 23015, ISO 3015, ISO 3016, IP 15 TPZ-LAB-22 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-22 is a built–in cooling unit capable of cooling the test cell to -95 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 45 ml The operating temperature range of the test cell is -95...48°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 500 W Overall dimensions 300x560x550 mm Weight 25 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg