Search

458 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 105
    Names
    Loading...
  • 42
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 48
    Additional
    Loading...
View:
458 products
THE DEVICE FOR ACHIEVING BALANCE
THE DEVICE FOR ACHIEVING BALANCE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), mixing of the contents of the syringe with oil is used to accelerate the extraction of gases (to achieve an equilibrium distribution of gases dissolved in oil between the liquid and gas phases). For this purpose, as well as automation of the mixing process, a special autonomous device for achieving equilibrium is produced. technical specifications The rotation speed of the syringe drum is 30 rpm./min. The rotation time (determined by the internal timer, after pressing the "Start" button) is 10 minutes. The number of syringes placed is 4. The volume of syringes is 20 or 50 ml. Power consumption, no more than — 14 VA. Overall dimensions, no more than 210×280×270 mm. Weight, not more than — 5 kg.
Produced in: Yoshkar-Ola, Mari El
THERMAL DESORBER TDS-3
THERMAL DESORBER TDS-3
The TDS-3 includes a heating column with a sorption tube, which is installed on the evaporator of the chromatograph and a control unit located on a special bracket on the right side panel of the chromatograph Technical characteristics of TDS-3 Desorption temperature (column heating), 0C to 400 Heating speed, 0C/min at least 500 The cooling time when moving to a cold zone is no more than 10 seconds. Cooling time from 300 0C to 50 0C, min. no more than 10 Continuous operation mode Power consumption, W not more than 250 Dimensions of the sorption tube, (Ø, length), mm. Material glass, stainless steel 5/110, 5/114, 6/115, 6.35/89 Electric power supply from 187 to 242 V, 50 Hz. The display of the measured temperature and the setting of the temperature on the display is The discreteness of setting the desorption temperature, 0C 0.1
Produced in: Yoshkar-Ola, Mari El
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
Pilot fermenter 15-50 L for pharmaceuticals
Pilot fermenter 15-50 L for pharmaceuticals
Biotechno pilot fermenters have a fully aseptic design and are easily validated. The universal C-Bio control system, unified for fermenters of any volume, greatly simplifies the scaling process and allows you to transfer fermentation data to larger fermenters. The total volume is 15-50 liters Working volume 10.5-35.0 l Material of manufacture: 316L stainless steel (for parts in contact with the product) Stainless steel grade 304L (for parts not in contact with the product) Design pressure 3.0 kg/cm3 (capacity) 4.0 kg/cm3 (jacket) Design temperature 143°C (capacity) 151°C (shirt) Surface treatment Internal polishing 0.4 µm + electropolishing External polishing 1.2 µm Ports on capacity Upper Port for diaphragm pressure gauge Port for diaphragm pressure transmitter Bursting membrane Exhaust gas outlet and condenser Inoculation Viewing window Foam sensor port Nozzle for CIP Spare port Upper side walls Air supply Viewing window Culture liquid supply x 3 Ring Bubbler Spare port Lower side walls Port for PT100 temperature resistor sensor Port for pH sensor Port for dissolved oxygen sensor Spare port Sampling port Shirt Steam supply / outlet of the cooled water Steam output / Cold water supply (including safety valve and pressure gauge) Low drain valve 2. Mixing mechanism Top drive with single mechanical seal 0.25 kW DC motor Speed 30-600 rpm (inverter control) Val – F20 Adjustable three-level paddle stirrers 3 welded partitions 3. Aeration mechanism Automatic air supply 2 VVM 5" high-efficiency 0.2 µm filter and 316L stainless steel filter housing Automatic Air flow meter 4. Pressure mechanism The bursting disc Pressure gauge Positioner Pressure sensor Pressure control valve 5. pH/DO control mechanism pH sensor pH Sensor Holder Cable for pH sensor DO sensor DO Sensor Holder Cable for the DO sensor Peristaltic pump (fixed 20 rpm) x 2 Bottle 1 l x 2 6. Defoaming mechanism Defoaming sensor Cable for defoaming sensor Peristaltic pump (fixed 20 rpm) x 1 1 L x 1 bottle 7. Temperature control mechanism Temperature sensor (PT 100) Heat exchanger Pump 8. Strapping and frame Support Corners and channels – STS304 Manufactured strapping Air supply Supply of process steam Supply of pure steam Cooling water supply Return of cooling water Drain of waste water Drain of waste liquids Exhaust gas output Instrumentation Diaphragm valve Direct flow valve Steam trap Membrane pressure gauge Ball valve and pneumatic angle valve Check valve Safety valve Crankshaft, tee Welding of pipes Orbital welding (line in contact with the product) Manual welding (common line)
Produced in: Moscow
Two-channel portable gas chromatograph FGH-1-2
Two-channel portable gas chromatograph FGH-1-2
from 1 030 000 ₽
The FGH-1-2 chromatographs have retained the main advantages of the FGH-1 model – mobility and ease of operation and maintenance. At the same time, FGH-1-2 has all the advantages of a modern multichannel chromatograph – the ability to reliably identify and accurately determine the concentrations of various pollutants of environmental objects. The additional use of automatic identification in the processing of chromatograms simultaneously through both channels makes FGH-1-2, in fact, a universal selective gas analyzer of organic substances using the chromatographic separation method. In FGH-1-2, as well as in FGH-1, all methodological problems have been solved: all measurement methods (MI) used are certified, the devices are equipped with sampling devices prescribed in MI, the devices are graded according to the required substances, independent control of the stability of calibration characteristics and measurement errors is provided.
EKAN
Moscow
Produced in: Moscow
PA-1 Portable Aspirator
PA-1 Portable Aspirator
The PA-1 single-channel portable aspirator is based on the PC-1 portable compressor. It provides air aspiration with a flow rate from 0.1 to 0.8 l/min. The aspirator is powered by an integral battery.
EKAN
Moscow
Produced in: Moscow