VacProtect VPA-200 POZIS Active refrigerator for storing vaccines
VacProtect VPA-200 POZIS Active refrigerator for storing vaccines
from 114 333 ₽
Electronic control Refrigerant R600a Total volume, l. 200 Number of compressors, pcs. 1 Height, mm 1660 Depth, mm 860 Width, mm 730 Weight, kg., no more 100 Rated power consumption, W 160 Voltage, 220 V Warranty, 1 year Cold storage Temperature in the refrigerator, °C +2...+8 Freezer Thermal card: yes Cold storage battery, pcs 51 Efficiency and power consumption Electricity consumption, kWh/day, not more than 0.35 Frequency, Hz 50
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HK-400-2 POZIS Blood storage refrigerator
HK-400-2 POZIS Blood storage refrigerator
from 59 820 ₽
Total volume, l. 400 Number of compressors, pcs. 1 Height, mm 1950 Depth, mm 610 Width, mm 600 Weight, kg., no more 72 Rated power consumption, W 300 Maximum rated power, W 315 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 1.42 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 72 Gross weight of the product, kg 76.5 Volume of packaging, m3 0.827 The length of the package, m 0.65 The width of the package, m 0.63 The height of the packaging, m 2.02
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HC-400-1 POZIS blood storage refrigerator
HC-400-1 POZIS blood storage refrigerator
from 56 802 ₽
Total volume, l. 400 Number of compressors, pcs. 1 Height, mm 1950 Depth, mm 610 Width, mm 600 Weight, kg., no more 72 Rated power consumption, W 300 Maximum rated power, W 315 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Additional transparent doors that prevent unwanted air exchange between compartments. Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 1.42 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 72 Gross weight of the product, kg 76.5 Volume of packaging, m3 0.827 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 2.02
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
HK-250-2 POZIS Blood storage refrigerator
HK-250-2 POZIS Blood storage refrigerator
from 32 621 ₽
Refrigerant R600a Total volume, l. 250 Number of compressors, pcs. 1 Height, mm 1300 Depth, mm 610 Width, mm 600 Weight, kg., no more 50 Rated power consumption, W 200 Maximum rated power, W 225 Voltage, 220 V Warranty, 1 year Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2...+6 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, no more than 0.74 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 49 Gross weight of the product, kg 52.5 Volume of packaging, m3 0,557 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
THERMAL DESORBER TDS-2
THERMAL DESORBER TDS-2
TDS-2 is a syringe (see Fig. 1), which is installed on the evaporator of the chromatograph. The device is equipped with a crane that cuts off the carrier gas line when removing the rod with the sorption tube from the thermal desorber. When the tap is open, the stem is lowered to the lower position and the sorption tube is inserted into the evaporator brought to the desired temperature. In the conditions of the upper position of the rod, it is also possible to displace air by purging the sorption tube with a carrier gas. Technical characteristics of TDS-2 The heating time to the desorption temperature is no more than 1 sec. The cooling time when moving to a cold zone is no more than 10 seconds. Outer diameter 5-0.1 mm Dimensions of the sorbent chamber: diameter 3.4+0.3 mm length 52 mm (470 µl) Volume (for solid samples) 90 µl Operating temperature ranges* from 50° to 400 °C Overall dimensions (height with the rod fully extended) 320 mm. Weight 0.325 kg.
Produced in: Yoshkar-Ola, Mari El
Pestle for homogenization 1.5-2.0 ml.
Pestle for homogenization 1.5-2.0 ml.
from 450 ₽
Pestles for homogenization For suspension in test tubes of 1.5/ 2.0 ml, 10 pcs. in the package Compatible with electromechanical drive for pestles Analog: SSI Material of manufacture: PP Packing: 10 pieces.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El
TWO-STAGE THERMAL DESORBER TDS-4
TWO-STAGE THERMAL DESORBER TDS-4
The composition of the TDS-4 includes the thermal desorber itself (the thermostat of the sorption tube, a cryolovushka, an automatic switching valve, a touch control panel), a heated transition line that is installed in the evaporator\ Technical characteristics of TDS-4 Temperature of thermal desorption, 0C to 400 The heating rate of the sorption tube, 0C/min up to 500 Trap temperature, 0C from minus 25 to 400 Trap heating speed, 0C to 2000 The method of heating the trap is direct Tap heating temperature, 0C to 250 Transition line heating temperature, 0C to 250 Continuous operation mode Dimensions of the sorption tube, (diameter; length), mm. Material glass, stainless steel 5/114 (on request 6/115, 6,3/89 and their combinations) Tube material glass or stainless steel (SS316) Method of trap cooling without using liquid refrigerant The number of regulated gas flows is not less than 2 There is an automatic leak test function There is a function of automatic purging of the sorption tube Electric power supply from 187 to 242 V, 50 Hz Power consumption, W not more than 700
Produced in: Yoshkar-Ola, Mari El
METANATOR
METANATOR
To analyze small concentrations of carbon monoxide (CO) and carbon dioxide (CO2), instead of the usual catarometer for these gases, a more sensitive PID is used, while carbon oxides are converted into methane (CH4) using reaction chromatography. The device implementing the conversion reaction is called a methanator, i.e. a device with a special catalyst that converts CO, CO2 into methane in a hydrogen current, while the latter is either a carrier gas itself, or is blown together with the carrier gas into the methanator through a tee. The methanator provides a highly efficient conversion reaction, while the detection limit of carbon oxides reaches 0.1 ppm. technical specifications Metanation temperature — 330 °C The coefficient of metanation is not less than 95 % The effective volume of the methanator is 1 ml.
Produced in: Yoshkar-Ola, Mari El
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC-MS CHROMATOGRAPH SYSTEM "CRYSTALLUX-4000M" WITH MSD "MAESTRO-AMC"
GC and MS interface Capillary direct interface, independent temperature control (50-300 0 S) The filament of the cathode (filament) is a double filament for electron ionization (EI), the maximum current is 300 µA. Double thread increases the service life. Two independent switchable cathodes Temperature of the ion radiation source Independent heating and temperature control, maximum value 350 0 C (adjustable) Transparent polymer window on the front panel there is no visual control of the state of the cathodes Ion radiation source Lenses made of ceramic and with a patented coating enhance the focusing effect, which significantly increases the efficiency of ionization, an electrode with a patented reflective surface improves focusing Tubular lenses enhance the focusing effect, which significantly increases the ionization efficiency, an electrode with a patented reflective surface improves focusing Energy ionization 10-100 eV The mass analyzer is a high-precision quadrupole with a filter that reduces the contamination of the main quadrupole and eliminates the influence of photonic noise on the analysis High-precision molybdenum quadrupole with prequadrupole (replaceable), which reduces the contamination of the main The detector is an electronic multiplier with a high-voltage secondary emiting electrode (dinode) of high energy 3D geometry to improve sensitivity. The amplifier of weak voltage signals effectively reduces network noise, improves the signal-to-noise ratio during electron ionization and provides a large linear dynamic range. It is possible to install an additional detector Mass range 2.0-1200 a.e.m. 1.5-1050 a.e.m. Mass stability Less than 0.1 a.e.m. for 48 hours Signal ratio noise At least 1500:1 with mass to charge (m/z) 272 At least 150:1 with mass to charge (m/z) 272 (with signal filtering 500:1) Linearity Not less than 107 Not less than 106 Precision < 5% RSD 9n=7, SIM, 100 fg OFN) no System sensitivity IDL < 10 fg (SIM mode, OFN according to m/z 272) no Maximum scanning speed 20000 a.m./s 11000 a.m./s Operating modes Scap, SIM, Scan/SIM, MicroScan and the innovative Flexible-SIM algorithm for finding trace amounts of components no Setting Automatic setting MSD on the PFTBA spectrum and m/z control of oxygen, nitrogen and water no Pumping pump Oil plate-rotor vacuum pump with a pumping speed of 66 l/min Oil plate-rotor vacuum pump with a pumping speed of 165 l/min Turbo pump Turbo molecular pump with magnetic levitation, with a pumping speed of 85 l/s (can be replaced by 300 l/s) Turbo molecular pump with magnetic levitation, with a pumping speed of 71 l/s (possible replacement by 260 l/s) RF detector power Allows you to use three points for calibration in the entire mass range and get good linearity in scanning mode Software Rus./ Eng. The ability to search and extract structural, graphical formulas. Library of 240,000 spectra. The ability to isolate individual components from overlapping peaks. In addition to spectra and compounds, the library contains the element name, formula, molecule structure, molecular weight, CAS number, analysis conditions, synonyms, and estimated or measured retention readings. The NIST EI library contains: drugs, metabolites and poisons, pesticides and fungicides, organic substances present in soil, water and air, amino acids, di- and tripeptides, common sample pollutants, common analytical derivatives, etc. Ethernet interface, remote access function implemented Touch screen Display of parameters and monitoring of system status no Built -in power supply Allows you to turn off the detector in normal mode if there is no power supply violation
Produced in: Yoshkar-Ola, Mari El