Search

471 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 109
    Names
    Loading...
  • 41
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 43
    Additional
    Loading...
View:
471 products
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Cultivator KVM-08 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-08 (TU 26.51.70-003-63790925-2021 )
from 240 000 ₽
1 supp.
This cultivator is an improved model of cultivators of the KVM type of earlier execution. Previously, KVM cultivators had a narrowly focused orientation to the Grigoriev Yu.S. methodology. 14.1:2:3:4.10-04 / 16.1:2:2.3:3.7-04; FR.1.31.2009.06642 (biotest on the reaction of a thermophilic strain of chlorella algae, test function - cell growth in relation to control. the duration of the test is 22 hours, toxicity criteria: 20% suppression of growth. 30% - stimulation of growth in relation to control). The Europolitest company strives to provide Russian laboratories with the best equipment with extensive functionality. Today. we have released a new cultivator KVM-08 with touch control. It can still be used according to the above method (in the same mode - power from the 220V household network via the power supply) At the same time, this cultivator can be connected to the on-board network of climatostats (P2, B3 and B4). In this case, it can maintain the temperature control at the level of 20 gr. With (despite the fact that the climatostat will be configured to maintain 18 gr. S). That is, when connecting this cultivator with the on-board network of the climatostat, the cultivator allows you to work in a wider temperature range (20 - 32 gr. S) And when working from 220V - in the range (27 - 40 gr. S.) In such a way thus, this cultivator allows you to consistently carry out two techniques: 1). 14.1:2:3:4.10-04 / 16.1:2:2.3:3.7-04; FR.1.31.2009.06642 (when operating from 220 V without using a climatostat) 2). RD 52.24.905-2020 (when the cultivator is connected to the on-board network of climatostats (P2, B3 and B4) In addition, with new characteristics and functionality, this cultivator is a convenient research tool. In addition to the preset modes for biotests according to the two above methods, the cultivator has 3 three user modes for free programming by the operator Allows you to configure and "flash" individual parameters: - temperature control : any value from the range of 20 - 40 gr. C (take into account the restrictions for work from 220 or from the board. climatostat networks) - lumostating : the maximum value is 16,000 Lux, the cultivator allows you to adjust from 0 to 100 % - rotation speed of the drum with penicillin vials (24 pcs.) : 0 - 60 rpm - duration of exposure: 0 - 240 h (discreteness of 1 min) - sound notification of the end of the specified exposure time
Evropolitest
Ivanteevka
Produced in: Moscow region
Vacuum tube MiniMed with coagulation activator, 2ml, 13×75mm, orange, PET, pack.100 pcs,
Vacuum tube MiniMed with coagulation activator, 2ml, 13×75mm, orange, PET, pack.100 pcs,
from 690 ₽
The walls of the tubes are coated with a dry clot formation activator (silicon dioxide) to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*75 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 3.6 ml,13*75 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA and separation gel, 10 ml, 16×100mm, purple, PET, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA and separation gel, 10 ml, 16×100mm, purple, PET, pack.100 pcs.
from 1 710 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Gel is a special material designed to form a stable barrier between the cellular components of blood and serum during centrifugation. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with coagulation activator, 7ml, 13×100mm, orange, glass, pack.100 pcs
Vacuum tube MiniMed with coagulation activator, 7ml, 13×100mm, orange, glass, pack.100 pcs
from 1 673 ₽
The walls of the tubes are covered with a dry clot formation activator to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Pestle for homogenization 0.5-0.6 ml.
Pestle for homogenization 0.5-0.6 ml.
from 450 ₽
Pestles for homogenization For suspension in test tubes of 0.5-0.6 ml. Compatible with electromechanical drive for pestles Pestles for micro-tubes Analog: SSI Material of manufacture: PP Packing: 10 pieces.
VIS MED
Berdsk
Produced in: Berdsk, Novosibirsk region
Vacuum tube MiniMed with K3-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K3-EDTA, 4 ml, 13×75mm, purple, PET, pack.100 pcs
from 690 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
Vacuum tube MiniMed with sodium heparin, 6 ml, 13×100 mm, green, PET, pack.100 pcs,
from 1 100 ₽
Test tubes are used to count blood cells and study plasma parameters. When mixed with the collected material, heparin blocks the activity of thrombin and inhibits the transition of soluble fibrinogen to insoluble fibrin, inactivating the coagulation factors irreversibly. Material for research............... heparinized blood, plasma Scope of application............................ immunology, hematology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Isothermal amplification
Isothermal amplification
from 750 ₽
Field of application: - Real-time loop isothermal amplification with Using SYBR Green I intercalating dye - loop isothermal amplification with endpoint detection.
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk
Vacuum tube MiniMed with separating gel, 2 ml, 13×75 mm, red, glass, pack.100 pcs
Vacuum tube MiniMed with separating gel, 2 ml, 13×75 mm, red, glass, pack.100 pcs
from 1 208 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, PET, pack.100 pcs,
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, PET, pack.100 pcs,
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region