Search

454 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 105
    Names
    Loading...
  • 42
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 47
    Additional
    Loading...
View:
454 products
Vacuum tube MiniMed with K2-EDTA, 1ml, 13×75mm, purple, glass, pack.100 pcs.
Vacuum tube MiniMed with K2-EDTA, 1ml, 13×75mm, purple, glass, pack.100 pcs.
from 931 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
rhVEGF-A121
rhVEGF-A121
from 14 000 ₽
Vascular Endothelial Growth Factor is one of the key regulators of angiogenesis. The most important role in the human body is played by a protein of the VEGF family called VEGF-A. VEGF-A is a 45 kDa glycoprotein homodimer and plays a key role in chemotaxis and angioblast differentiation, endotheliocyte (EC) proliferation, vasculogenesis, and vascular remodeling. As a result of alternative splicing or proteolytic cleavage, 4 main isoforms of VEGF-A are formed, consisting of 121, 165, 189, or 206 amino acid residues.
Produced in: Moscow
Vacuum tube MiniMed without filler, 5 ml, 13×75 mm, red, glass, pack.100 pcs
Vacuum tube MiniMed without filler, 5 ml, 13×75 mm, red, glass, pack.100 pcs
from 1 143 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*75 mm, blue, PET,pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*75 mm, blue, PET,pack.100 pcs
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, glass, pack.100 pcs,
Vacuum tube MiniMed with separating gel, 4 ml, 13×75 mm, red, glass, pack.100 pcs,
from 1 208 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation. Research material............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
GeneMack Strela Automatic Nucleic Acid Isolation Station
GeneMack Strela Automatic Nucleic Acid Isolation Station
1 supp.
The Strela automatic nucleic Acid isolation station is suitable for laboratories with a small sample flow seeking to optimize workflow and improve reproducibility of results. The station is being developed and assembled in Russia. Station Features: • Separation on magnetic particles – high yield of nucleic acids and excellent purity • The quality and concentration of the resulting DNA is sufficient for all molecular applications, including NGS • Ability to work with different types of samples, including complex samples (whole blood, FFPE, cfDNA, dry blood stains, saliva, hair, nails, etc.) • Simultaneous isolation of 1 to 13 samples • About 30 minutes per allocation, depending on the protocol • No overspending of plastic – load exactly as many cartridges as you are going to allocate samples • A large number of built-in protocols, the ability to program your protocols for different cartridges • User-friendly and intuitive interface • The station is compatible with cartridges from different manufacturers • 24/7 technical support in Russian Technical specifications Device Type: Desktop automatic device Minimum load: 1 sample Maximum load: 13 samples Reagent format: Bottled and sealed in individual cartridges Protocol execution time: From 16 to 60 minutes (depending on the allocation protocol program) Dosage volume: 25-1000 µl Dosing accuracy: No more than 5% CV Control: LCD Touch screen, 7 inches, 1025x600 Software language: Russian Heating unit with temperature control: from 30C to 80C (at room temperature+ 25C) UV lamp: Available Input voltage: 220V Overall dimensions (W x L x H): 54 x 57 x 61 cm Weight: 60 kg The installation location is only indoors Ambient operating temperature 15-40°C
Aivok
Zelenograd
Produced in: Moscow, Zelenograd
Sigmed MC-01 Microcentrifuge
Sigmed MC-01 Microcentrifuge
Functionality 1. Centrifugation function (300 - 4000 rpm). 2. Shaking function (forward-reverse rotation with a frequency of 2 sec.). 3. Mixing in the flask (up to 400 rpm). 4. Mixing in a test tube (500 rpm). 5. Full loading: 12 plastic tubes of the Eppendorf type with a volume of 1.5 ml or 2 ml Safety 1. Blocking operation when the lid is open. 2. Stops working when opening the lid. 3. Stops working when the mains voltage disappears; it does not restart when the mains voltage appears again. 4. Automatic shutdown after 60 minutes. 5. Low-voltage power supply (+24V). Ergonomics 1. Simple and intuitive arrangement of controls. 2. RPM or linear g-load are displayed on the readout.
Produced in: Kaluga region, Obninsk
Vacuum tube MiniMed with sodium citrate 3.2%, 5.4 ml,13*100 mm, blue, PET,pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.2%, 5.4 ml,13*100 mm, blue, PET,pack.100 pcs
from 732 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed without filler, 4 ml, 13×100 mm, red, PET, pack.100 pcs,
Vacuum tube MiniMed without filler, 4 ml, 13×100 mm, red, PET, pack.100 pcs,
from 679 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum tube MiniMed with K2-EDTA, 7 ml, 13×100mm, purple, PET, pack.100 pcs
Vacuum tube MiniMed with K2-EDTA, 7 ml, 13×100mm, purple, PET, pack.100 pcs
from 849 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Laboratory mill VYUGA-GMO
Laboratory mill VYUGA-GMO
1 supp.
GENERAL CHARACTERISTICS: • Possibility of cleaning and autoclaving of all parts of the grinding set The grinding chamber of the mill and all parts of the grinding set that come into contact with the sample can be easily removed for cleaning and autoclaving, which is an important condition for sample preparation in the determination of GMOs. • Minimal heating of the sample during grinding The special design of the grinding chamber and the use of special knives guarantee minimal heating of the laboratory sample, which eliminates the negative impact on the quality of the extracted DNA. • Grinding with the required quality and homogenization of the sample in one grinding step The ability to select the optimal combination of blade rotation speed, grinding time and automatic rotation of the grinding unit guarantees high-quality, fast grinding and homogenization of samples for various types of samples. • Reproducible grinding results Automation of the grinding process and digital time setting ensure high reproducibility of grinding results. • Easy operation with information display The mill is easy and convenient to operate. Time and grinding mode are set by one button. The information display will show the grinding process parameters. • Grinding of samples with high fat content (up to 55%) The automatic 210° and 90° automatic cycling of the grinding unit, combined with a high grinding speed, minimizes sample heating and oiling of the grinding chamber, which guarantees high-quality, fast grinding and homogenization of samples with a high fat content. 3 grinding chambers are included in the DELIVERY SET of the VYUGA-GMO mill. By separate order it is possible to purchase the required number of grinding chambers.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg