Search

210 products
View:
  • Selected: 1
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
  • 80
    Names
    Loading...
  • 31
    Manufacturer
    Loading...
  • 18
    Made in
    Loading...
  • 52
    Additional
    Loading...
View:
210 products
MTP-01 Magnetic Coating Thickness Gauge
MTP-01 Magnetic Coating Thickness Gauge
from 90 000 ₽
Measuring range of thickness of protective coatings, mm: from 0.2 to 10 Digital display of measurement results: yes Power supply: from a PP3 type battery with a voltage of 9V Power consumption, MW: 100 Operating mode setting time, min: 1 Time of one measurement, sec: 3 Memory capacity, number of thickness values: 2000 Overall dimensions, mm: - electronic unit (width-depth length) 120x60x25 - measuring transducer (diameter height) 33x23 - connecting cable (length) 1500±300 Weight, g, no more: - electronic unit (without battery power) 80 - measuring converter 40 The kit includes: - Electronic unit, - Measuring converter - Plate made of non-magnetic material for setting the upper limit of measurements - Battery type PP3 - CD-ROM with the program - Prism - Cover - Spring - Case - Passport - Operation Manual
Produced in: Moscow
Quenching oil tank BZM 10.12.15/06
Quenching oil tank BZM 10.12.15/06
from 2 959 292 ₽
Oil quenching tanks of the tank type are designed for quenching cooling of products heated to the quenching temperature in oil at temperatures up to 90 ° C in stationary conditions. The workspace environment is oil. Quenching oil tanks "BZM-10.12.15/0.6" are designed to remove the steam jacket from the surface of the part in oil with mixing in a laminated flow with maintaining the temperature of the liquid. Water, oil, or polymer liquid can be used as a working fluid in the quenching oil tanks "BZM-10.12.15/0.6". The tank is welded from a metal profile and is a rigid power structure. U–shaped heating elements with a capacity of up to 40 kW are installed on the inner side. Cooling is carried out by means of a heat exchanger (coil) installed in the working space. Cold process water from the mains is used for cooling. Optionally, tanks (or a complex of tanks) can be equipped with a chiller or a cooling tower. The liquid level maintenance system ensures a constant level of liquid in the tank. A level sensor is installed to monitor the level. When the liquid level in the tank decreases, the liquid is refilled automatically. Mixing of the liquid in the tank is provided by means of a stirrer located at the bottom.
Produced in: Tula
Universal Metolab 701 Hardness Tester
Universal Metolab 701 Hardness Tester
METOLAB 701 is a stationary universal hardness tester that allows you to control these parameters according to the Brinell, Rockwell (A, B and C) and Vickers scales. The device has an electromechanical drive for applying and removing the main load, and is also equipped with a small LCD indicator that displays the exposure time. The main indicator of the device is analog, clock type. Also, the METOLAB 701 hardness tester is equipped with a measuring microscope with illumination. The stationary universal METOLAB 701 hardness tester is designed to measure the hardness of various materials and products (steels, cast iron, non-ferrous metals, soft alloys, etc.) according to the Brinell, Rockwell, Vickers scales. Distinctive features of the stationary universal METOLAB 701 hardness tester: Scales for Rockwell measurements: HRA, HRB, HRC; Scales for Brinell measurements: HBW2.5/31.25, HBW2.5/62.5, HBW5/62.5, HBW2.5/187.5, HBW 10/100, HBW 1/30; Vickers measuring scales: HV30, HV100; Easy to manage and maintain, low cost of measurements; Electromechanical drive for application and removal of load; Analog clock type indicator; Built-in microscope with two additional 2.5 and 5x lenses and backlight. Basic delivery package: Stationary universal METOLAB 701; Conical diamond Rockwell indenter (120° angle) - 1 pc.; Vickers diamond indenter (136° angle) - 1 pc.; Indenter with 1.5875 mm ball - 1 pc.; Indenter with 2.5mm ball - 1 pc.; Indenter with 5.0 mm ball - 1 pc.; Large flat table 150 mm - 1 pc.; Medium flat table 60 mm - 1 pc.; V-shaped table 40 mm - 1 pc.; Hardness measures - 1 set; 15x microscope - 1 pc.; 2.5x lens - 1 pc.; 5.0x lens - 1 pc.; User Manual.
Metolab
Moscow
Produced in: Moscow
High Temperature Laboratory furnace SNO 30/17
High Temperature Laboratory furnace SNO 30/17
Designation SNO 30/17 Rated power Pmax, kW 12 Power supply voltage U, In 3 phases + N+PE 380 Maximum operating temperature T slave, oS 1700
Produced in: Tula
NTEGRA Spectra II
NTEGRA Spectra II
NTEGRA Spectra II is already a second-generation measuring system that successfully demonstrates the unification of two worlds: AFM and Raman spectroscopy. It can perform multiple functions ranging from relief mapping to 2D spectral analysis, from studies of electrical and mechanical properties to optical measurements with a resolution below the diffraction limit. Now scientists can conduct a complete physico-chemical analysis of the surface properties of the sample at a time. As a result, researchers get unlimited opportunities to develop their laboratory techniques.
Produced in: Moscow, Zelenograd
Tubular furnace MA-0,25.1.1/12MR-I3 (DETACHABLE)
Tubular furnace MA-0,25.1.1/12MR-I3 (DETACHABLE)
from 47 800 ₽
Tubular furnaces MA are designed for heating chemical equipment with analytes in installations for microanalysis of organic compounds and other work at temperatures up to 1200 ° C.
Produced in: Tula
UN-5 Magnetizing device
UN-5 Magnetizing device
from 95 550 ₽
The principle of operation of the magnetization device: The device consists of two compact blocks made of non-magnetic material connected by a flexible magnetic circuit. In each block there is a permanent magnet made of neodymium-iron-boron alloy (Ne-Fe-B). When installing the blocks on the surface of the part, a closed magnetic circuit is formed with the direction of the magnetizing field from one pole to the other. Above the defect scattering fields, magnetic powder particles are deposited to form an indicator pattern. Design features and advantages of the device for magnetic particle control UN-5 The delivery package with the device includes a portable case, an inter-pole jumper installed during transportation, and a liner for fixing blocks with permanent magnets. The UN-5 portable device does not require electrical power and therefore can be used where the supply of stationary power is difficult or impossible under regulatory documents: in the field, when working at height, for inspection of capacitive equipment operating under pressure, etc. - The device is easy to use, lightweight and small-sized, working with it does not require special physical and technical training from the operator; - Flexible magnetic core allows you to use the device to control parts of complex shape; - The UN-5 magnetizing device is distinguished by an increased quality of the indicator pattern and an increased control zone due to a reduced uncontrolled zone near the poles and an improved ratio of the normal and tangential components of the magnetic field (Russian patent No. 60732); - The technical characteristics of the device comply with Russian and foreign regulatory documents, this being the reason of its widespread use in more than 40 countries, including Germany, France, Brazil and Norway. When monitoring, the controlled area is the central part of the area located between the magnetic poles of the device. The width of the monitored area is determined by the width of the magnetic poles of the device and is approximately 60 mm. The length of the monitored section depends on the inter-pole distance. the dimensions of the controlled area are given depending on the device's inter-pole distance: Inter-pole distance, mm 95: 75 55 Controlled area between the working poles, mm: 60x60 40x60 25x55 The length of the defect detection zone depends on the distance established between the working poles of the magnet on the controlled product. Defects are not detected in the areas adjacent to the poles of the magnet. The length of these sections is 18 mm with an interpolar distance of 95 and 75 mm. With an interpolar distance of 55 mm these sections are 13 mm long. Scope of application: Magnetizing devices for magnetic powder flaw detection are used in many industries, including railway, water and aviation transport, in the construction and operation of pipelines, in chemical and petrochemical production. The flexible link between the magnetic blocks allows the control of products of complex shape, for example, cylindrical tanks, high-pressure apparatuses, main pipelines, etc. When checking for defects, the device can be used together with other auxiliary equipment for: - preliminary and subsequent demagnetization; - application of a magnetic indicator (which can be dry or in the form of an emulsion); - magnetoluminescent control (with ultraviolet lamps).
Produced in: Moscow
Resistance chamber high-temperature electric furnace with a pull-out hearth SNOT 8.16.6/16
Resistance chamber high-temperature electric furnace with a pull-out hearth SNOT 8.16.6/16
from 19 000 000 ₽
Designation SNOT 8.16.6/16 Heating chamber power, kW 120 Supply network voltage, V 380±15% Frequency, Hz 50
Produced in: Tula
MAX-GF1(2)E-C Spectrometer
MAX-GF1(2)E-C Spectrometer
The X-ray fluorescence spectrometer SPECTROSCAN MAX-GF1(2)E-C combines two methods of detecting an analytical signal: diffraction on a crystal (wave dispersion - WDX) and energy dispersion (EDX) method, as well as sample delivery adapted for the analysis of large-size images. The collimation of the primary radiation of the X-ray tube and the special design of the sample presentation make it possible to analyze the sample over an area of 1 cm2 in 1 mm increments, and thus investigate the distribution of elements over an area. The spectrometer is designed to determine the contents of elements in the range from Ca to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. With the help of fixed energy dispersion channels, any one or two additional elements in the range from magnesium (Mg) to calcium (Ca) can be determined. With the help of this modification of the spectrometer, forensic and customs examinations, judicial and forensic medical examinations, as well as art-historical examinations are carried out.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Metolab 604 Brinell Hardness Tester
Metolab 604 Brinell Hardness Tester
METOLAB 604 is a stationary hardness tester, a modification of the METOLAB 603 device without a personal computer, as well as with simplified technical characteristics. The METOLAB 604 hardness tester allows you to measure the hardness of various materials and products using the Brinell method, the HBW scale in full compliance with the current technical requirements in this area. The device is equipped with an automatic loading system and comes complete with a digital measuring microscope MPBC, designed for automatic reading of hardness values without using conversion tables. Due to its characteristics, the stationary METOLAB 604 hardness tester can be used to measure materials such as: steel, cast iron, non-ferrous metals, soft alloys, etc. The stationary METOLAB 604 Brinell hardness tester is included in the State Register of Measuring Instruments of Russia (GRSI) and comes with a certificate of primary verification (on request). The number in the GRSI is 65684-16. Distinctive features of the stationary METOLAB 604 Brinell hardness tester: Simple and intuitive interface, fully Russian-language device menu; A wide range of measured values – from 8 to 650 on the HBW scale; High accuracy and repeatability of results; The METOLAB 604 hardness tester is equipped with an electronic load value switch; The basic package includes a digital measuring microscope MPBC; The device is equipped with a bright and clear LCD display, which displays all the necessary service information; Printing of measurement results on the built-in printer; Automatic loading system. Basic package of delivery: Stationary METOLAB 604 hardness tester; Micrometer; Indenter with carbide ball (10; 5; 2.5 mm) - 1 pc.; Large flat table; Small flat table; V-shaped table; Brinell hardness measures - 1 set; User Manual.
Metolab
Moscow
Produced in: Moscow
Thermoelectric converter THA.GPKSH.013
Thermoelectric converter THA.GPKSH.013
The thermoelectric converter THA.GPKSH.013 is designed for measuring the temperature of gaseous and liquid chemical environments that do not destroy the protective shell. It measures the temperature in the clean air atmosphere, gaseous chemically non-aggressive environments with humidity up to 95 %
Termokon
Korolev
Produced in: Moscow region, Korolev