Chamber electric resistance furnace CHO-8.10.8
Chamber electric resistance furnace CHO-8.10.8
from 550 000 ₽
Designation: SNO-8.10.8 Temperature: 1200 Opendoors: electromechanical Camera size (w.G.V.):800x1000x800 Regulation zones: 1
Produced in: Tula
Laboratory shaft furnace SSHOL-10/11
Laboratory shaft furnace SSHOL-10/11
from 210 884 ₽
Designation SSHOL-10/11 Supply voltage, 220 ± 10% Network frequency, Hz 50 Power consumption, W, max 5000
Produced in: Tula
Shaft furnace industrial SSHO-6.6/11
Shaft furnace industrial SSHO-6.6/11
Designation SSO-6.6/11 Power, kW 45 Diameter, mm 600 Height, mm 600
Produced in: Tula
Shaft furnace industrial SSHO-6.12/11
Shaft furnace industrial SSHO-6.12/11
Designation SSO-6.12/11 Power, kW 75 Diameter, mm 600 Height, mm 1200
Produced in: Tula
Drum furnace SBO-2,5.13/10-I2PV
Drum furnace SBO-2,5.13/10-I2PV
The rotating furnace of indirect electric heating SBO-2,5.13/10-I2PV is designed for firing powdered ores to convert them into an oxide form at temperatures up to 1000 oC.
Produced in: Tula
Chamber electric resistance furnace CHO-8.16.5/12.5
Chamber electric resistance furnace CHO-8.16.5/12.5
from 550 000 ₽
Designation: SNO-8.16.5/12.5 Temperature: 1200 Open.doors: electromechanical Camera size (w.G.V.): 800x1600x500 Regulation zones: 2
Produced in: Tula
VD-20NF Eddy Current Flaw Detector
VD-20NF Eddy Current Flaw Detector
The principle of operation of the VD-20NF eddy current flaw detector The principle of operation of the VD-20NF flaw detector is based on the generation of eddy currents on the surface of the controlled part and subsequent analysis of the signal at the output of the converter, which correlates with the characteristics of the active secondary field. The device consists of two main blocks: electronic one and electromechanical one, in which an eddy current converter of transformer type is installed. The controlled products (bearing rollers) enter through the input tray into the electromechanical unit of the flaw detector, where they move sequentially and fall under the pressure rollers of the overhead converter holder. The clamping mechanism is adjusted to each size of the rollers, so as to ensure tight contact with the curved surface and fix the tip of the transducer at the required distance from it. The detection of defects occurs due to the imbalance of the converter when it is located above the surface of the controlled product, caused by the interaction of the primary electromagnetic field generated by the converter with the secondary electromagnetic field of eddy currents induced in the controlled product by the primary field. When cracks are detected, the electronic unit of the flaw detector gives sound and light warning signals, and also triggers the electromagnet of the sorter, which directs the controlled roller into the tray for defective products. In the absence of defects, the controlled roller is directed towards the output tray of the flaw detector. Design features and advantages The VD-20NF eddy current flaw detector is equipped with removable input and output trays, power-on switches and a drive for feeding controlled products to the converter, as well as handrails for convenient transportation of the unit. The mechanisms of the electromechanical unit are protected by a frame made of steel plates. The electronic unit of the flaw detector is portable and can be installed both on the top panel of the electromechanical unit and on the surface of the desktop. Controls and indications of defect detection are located on the front panel of the electronic unit. The delivery package also includes a power adapter for the electronic unit and a tuning sample. The advantages of the VD-20NF flaw detector include: high reliability (the service life of the flaw detector is more than 10 years); it is easy to set up and operate; it has several types of defect detection alarms; the high probability of detecting defective products (at least 99.9%); low number of false positives (less than 5%). Scope of application According to the current standards of safety and product quality control during repair work in locomotive depots and repair plants, bearing rollers that have passed visual inspection and are recognized as suitable for further operation according to the criteria of geometry and condition of the working surface are subject to mandatory additional control using eddy current flaw detection to detect fatigue cracks invisible during visual inspection on the rolling surface of the rollers. The VD-20NF eddy current flaw detector allows for quality control and automatic disassembly of bearing rollers of various shapes and sizes both in laboratory and factory conditions in full compliance with the requirements of the regulatory documents of Rosstandart and the methods of performing control measurements used in JSC "Russian Railways".
Produced in: Moscow
Spherical vacuum furnace with bottom loading ESQVE-13.0.3.0/9.5SHM12
Spherical vacuum furnace with bottom loading ESQVE-13.0.3.0/9.5SHM12
Spherical type vacuum furnace with bottom loading ESQVE-13.0.3.0/9.5SHM12 is designed for heat treatment of titanium rings at temperatures up to 950 degrees and vacuum up to 1x10-3mm Hg.
Produced in: Tula
High Temperature Laboratory furnace CHO 5/17
High Temperature Laboratory furnace CHO 5/17
from 1 524 600 ₽
Designation SNO 5/17 Rated power Pmax, kW 5 Power supply voltage U, In 3 phases + N+PE 220 Maximum operating temperature T slave, oS 1700
Produced in: Tula