Search

322 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 1
    Additional
    Loading...
All filters
  • 14
    Applying
  • 46
    Names
    Loading...
  • 31
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • Additional
    Loading...
View:
322 products
Test tube with screw cap PrimeLab, 30 ml, 20x150, round bottom
Test tube with screw cap PrimeLab, 30 ml, 20x150, round bottom
from 37 ₽
The PrimeLab screw cap tube holds 30 ml. The throat diameter is 20 mm with a height of 150 mm. Suitable for various laboratory processes involving reagent storage, experimentation, transportation, etc. The screw cap creates a sealed connection to the tube, thereby protecting the contents from external influences and preventing leakage. In some cases, this is extremely important and can affect the final outcome of an experiment or other laboratory process.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Reagent jar, Primelab light glass, 10000 ml
Reagent jar, Primelab light glass, 10000 ml
1 supp.
Reagent jar, light glass Primelab, 10000 ml is designed taking into account the requirements of safety, ease of use and all the nuances of working with reagents of different consistency. These are liquid, volatile, loose, chemically active acids and others. Thanks to the transparency of the glass, it is possible to observe all processes inside the jar in real time without opening the lid and excluding the impact of the external environment on the contents. Specifications: • Volume – 10000 ml • Height – 410 mm • Diameter – 234 mm • Thread - GL45.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Round bottom tube with screw cap PrimeLab, 15 ml, 16x150
Round bottom tube with screw cap PrimeLab, 15 ml, 16x150
from 16 ₽
The round-bottom test tube with a screw cap PrimeLab has a wide range of applications in laboratories, scientific enterprises and various industries. This includes storage of liquid, bulk or gaseous substances, transportation, research, etc. The screw-closure lid creates a complete seal. Protects contents from external influences and leakage. Test tube characteristics: • Volume - 15 ml • Diameter - 16 mm • Length - 150 mm.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Reagent jar, Primelab dark glass, 10000 ml
Reagent jar, Primelab dark glass, 10000 ml
The jar for reagents, dark glass PrimeLab, 10000 ml is equipped with a lid that closes firmly thanks to the GL45 thread on the neck of the container. Protects against leakage and evaporation. The wall has an area for notes and a measuring scale for quickly determining the volume of contents. Characteristics: • Volume – 10000 ml • Height – 410 mm • Diameter – 234 mm • Thread - GL45.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
Infrared analyzer "InfraLUM® FT-12" with a wake-up module
1 supp.
Technical specifications: Measurement time, sec. 80 Standard sample volume in a cuvette, 500 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, not more than 10 The limit of the permissible value of the absolute error of the wavenumber scale, cm-1 ± 0.5 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system (relative to the maximum signal), %, not more than ± 0.25 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, not less than 8 Overall dimensions, mm, not more than 530x485x495 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
1 supp.
Technical characteristics: Consumption of working reagents 1.0–2.0 ml – for standard filling cuvette K10 from 400 ml – for photometric techniques Filters for photometer mode, nm built-in interference filters 340, 405, 505 ,545, 575, 630 spectral half-width of 10 nm Filters for fluorimeter and chemiluminometer modes on request, in the spectral range of 270-850 nm Chemiluminescence channel sensitivity 10000 photons per second Optical density measurement range, E.O.P. 0-2.20 Photometric channel accuracy, %2 Memory of 100 measurement programs Temperature control of the measuring cell (for photometer and chemiluminometer modes) built-in thermostat on the Peltier element: 25, 30, 37 OC; accuracy ± 0.2 oC Volume of the flow cuvette, mkl 80 Pump type (only for photometer mode) peristaltic pump with programmable liquid supply volume Productivity, analyses/hour up to 100 (by the endpoint method) Information output liquid crystal display and personal computer Power supply, 220 ± 22 Dimensions, mm 430x350x160 Weight, kg 10
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory table of Classic LAB series
Laboratory table of Classic LAB series
1 supp.
Laboratory tables of Classic LAB series are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 650 to 900 mm and can withstand a load of up to 300 kg. The material of the countertops can be selected based on the tasks set.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Laboratory Table of Gamma LAB Series
Laboratory Table of Gamma LAB Series
1 supp.
The laboratory tables are based on a strong metal frame covered with chemically resistant paint, which is adjustable in height from 740 to 860 mm and can withstand a load of up to 200 kg. The material of the countertops can be selected based on the tasks set. The tables in a standard set have a main shelf made of chipboard or plastic (HPL, HPL PLUS) and a socket block built into the right or left panel (5 sockets with grounding, 1 socket without grounding, a switch-off button), the main LED lighting is built into the upper horizontal bracket.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg