Vacuum drying cabinet SNVS-50/3.5
Vacuum drying cabinet SNVS-50/3.5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
2NVBM-250/3000 Booster high vacuum pump
2NVBM-250/3000 Booster high vacuum pump
The 2NVBM-250(R)/3000 booster pump consists of housings, a steam pipe, a trap and a heater. The alignment of the steam line in the pump housing 2NVBM-250(R)/3000 is carried out by a steam line screed, which, when installing the housing on the collector, enters its upper end into the hole of the hood (oil reflector). The required effective speed of action of the forevacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-250(R)/3000 booster pump is not less than 25 l/s. The maximum residual pressure of the 2NVBM-250(R)/3000 pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6 × 10-4 Pa (5 × 10-6 mm Hg). The pressure of the cooling water at the inlet to the 2NVBM-250(R)/3000 pump should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2). The drain from the pump must be free with a jet break. Cooling water consumption is 360 l/h. The total amount of working fluid for the 2NVBM-250(R)/3000 pump is 17 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1 · 10-2 to 1 · 10-1 mm Hg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
LI-400 Integrated Vacuum Trap
LI-400 Integrated Vacuum Trap
The LI-400 integrated flanged trap is installed inside the diffusion pump instead of the standard oil reflector, without increasing the overall dimensions of the diffusion pump. The LI-400 trap performs the function of an oil reflector, is installed instead of a standard oil reflector in pumps, has an additional number of cooled screens for capturing oil return flow vapors (more than that of the MU trap), covers the entire area of the input high-vacuum flange.
Produced in: Kazan
Vacuum drying cabinet with manual control SNVS-215/3.5
Vacuum drying cabinet with manual control SNVS-215/3.5
from 896 374 ₽
The SNVS-215/3.5 vacuum drying cabinet with a volume of 215 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 350 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
Electric resistance chamber vacuum furnace SNVS-1.5.2.0/10SHM10
Electric resistance chamber vacuum furnace SNVS-1.5.2.0/10SHM10
The electric furnace SNVS-1,5.2,0/10SHM10 is designed for heat treatment in vacuum, according to the technological process. The execution Of The Electric Furnace is mine. The type of cage is monoblock or composite. The loading direction is vertical. The loading method is by universal shop lifting mechanisms.
Produced in: Tula
Vacuum chemical resistant membrane pump PL.HM01.01.10 Primelab
Vacuum chemical resistant membrane pump PL.HM01.01.10 Primelab
from 120 000 ₽
The vacuum diaphragm pump PL.HM01.01.10 has two working chambers, which are connected in series. They are made of fluoroplastic, and other products have a fluoroplastic coating, due to which the device has high chemical resistance. Fully compliant with IP20 protection class. Characteristics • Valve material (valves) standard: chloroprene copolymer NO-68-1 (TU 38 0051166-98) • Country Russia • Power: 180 W • Overall dimensions, L×W×H: 322x140x200 mm • Protection class acc. with DIN EN60529: IP20 • Noise level: 75 dB • Power: 220 V/50 Hz • Ultimate vacuum: 10* mbar abs. • Maximum permissible excess pressure: 0.5 bar. • Capacity: 38 l/min • Connection outer diameter, 9 mm. • Maximum current: 1.2 A • Device weight: 9 kg Equipment Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
AVD-50/16 Two-rotor vacuum unit
AVD-50/16 Two-rotor vacuum unit
The AVD-50/16 unit consists of a NVD-200 series-connected two-rotor vacuum pump and a 2NVR-60D plate-rotor vacuum pump. The pumps are connected to each other by means of an adapter, which acts as both a pipeline and a support unit. The AVD-50/16 unit can operate continuously at an inlet pressure of no more than 133 Pa (1 mm Hg) or pumping out one or more sealed vessels with a total volume of 3.5 m3 from atmospheric to maximum residual pressure for 8 hours.
Produced in: Kazan
ND-630 High-vacuum diffusion pump
ND-630 High-vacuum diffusion pump
The working condition of the ND-630 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (uner technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-630 diffusion pump is a maximum of 9 liters, a minimum of 6 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-630 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-630 diffusion pump up to 360°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 600 l/h, for the oil reflector it is 80 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).