LA-100 Nitrogen Vacuum Trap
LA-100 Nitrogen Vacuum Trap
The LA-100 nitrogen filler trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the elements of the freezing device cooled with liquid nitrogen.
Produced in: Kazan
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-14/2,5
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 10 mm Hg SHSV-14/2,5
The electric vacuum drying cabinet SHSV-11/2.5 is designed for drying and heating various materials in air and in vacuum at a maximum temperature of 250 ° C. In the model with the index "C", the door is made of heat- resistant glass. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C Operating temperature- 250 ⁰C Power consumption - 1000 watts Dimensions of the working chamber - 200x350x200 mm Dimensions WxDxH- 450x930x470 mm Weight - 20 kg
MIUS
Tula
Produced in: Tula
NVDM-160 High-vacuum Diffusion Pump
NVDM-160 High-vacuum Diffusion Pump
The operation of the NVDM-160 diffusion pump is based on the capture and transfer of the pumped gas by a steam jet flowing from the slit gaps of the steam line nozzles towards the outlet flange. The oil reflector of the NVDM-160 diffusion pump is a flange with a cooling tube passing through it, soldered to a cap located in the center of the flange. The NVDM-160 closed-type diffusion pump heater consists of tubular electric heaters fixed in the heater housing. During the operation of the pump, it is necessary to monitor the flow rate and temperature of the cooling water, the level of the working fluid and its temperature. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium. Therefore, the time after which the working fluid is replaced or refilled can be from 100 to 1000 or more hours. A large flow rate of the working fluid is observed when the pump is operating in the range of inlet pressures from 6.6×10-2 to 13.3 Pa (from 5×10-4 to 1×10-1 mm Hg). Water at the inlet to the cooling systems of the housing and oil reflector must be supplied with a pressure of no more than 0.5 MPa (5 kgf / cm2) and temperature from plus 40C to plus 250C. The recommended cooling water consumption is 60+10 l/h and is regulated by the outlet water temperature, which should not exceed plus 400C. The water drain should be free (with a jet break). Not allowed: operation of the pump without water cooling, exceeding the maximum exhaust pressure of 33.3 Pa (0.25 mm Hg). The level of the working fluid during operation, at which the parameters of the NVDM-160 pump are provided, must correspond to min 10mm, max 17mm. The volume of the filled working fluid is 0.3 liters
Produced in: Kazan
Clamps for ISO-K
Clamps for ISO-K
The clamp connection (DIN 28 404 and ISO 1609) allows connecting components from DN 63 to DN 630 in any position, on any fixed flange regardless of the location of the bolt holes.
Produced in: Kazan
MU-630 Enlarged oil reflector
MU-630 Enlarged oil reflector
The MU-800 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens to capture oil return flow vapors.
Produced in: Kazan
Vacuum drying cabinet with automatic regulation SNVS-90/5
Vacuum drying cabinet with automatic regulation SNVS-90/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
2VVN1-6M(N) Water ring vacuum pump
2VVN1-6M(N) Water ring vacuum pump
The use of a 2VVN1-6M(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the details of the 2VVN1-6M(H) pump. The 2VVN1-6M(H) vacuum water ring pump is manufactured in the climatic version of UHL (i.e. for moderate and cold climate) 4 and O4 according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
Vacuum drying cabinet with manual control SNVS-25/5
Vacuum drying cabinet with manual control SNVS-25/5
from 384 845 ₽
The SNVS-25/5 vacuum drying cabinet with a volume of 25 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 500 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
Crimp support rings (stainless steel) for sealing rings with high sealing capacity
Crimp support rings (stainless steel) for sealing rings with high sealing capacity
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan