Search

145 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 22
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • Additional
    Loading...
View:
145 products
ION-3701 Version "North"
ION-3701 Version "North"
from 77 245 ₽
A small-sized digital magnetometer (gaussmeter, teslameter), a residual magnetization meter ION-3701 version "North" is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in adverse climates, conditions of negative temperatures, the Far North and etc . It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Mercury analyzer "RA-915M" with the prefix "RP-92"
Mercury analyzer "RA-915M" with the prefix "RP-92"
1 supp.
Technical specifications: Continuous operation time 8 hours Analyzer dimensions (LxWxH), mm, no more than 470x110x220 mm Overall dimensions of the pumping unit: (LxWxH), mm, no more than 360x110x125 mm Analyzer weight 7 kg The weight of the console is 7 kg Power supply 100 - 240 V Powered by an autonomous RA source-915+ - 6/14 In Powered by an autonomous source RP-91 - 12 V Power consumption 20 W Current frequency 50/60 Hz The mass of the pumping unit is 3 kg Average service life, years, at least 5 Volume of the injected sample, cm3 0.5 - 10.0 Air flow, dm3/min 0.8 - 4.2
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-6100
Laboratory scales VLTE-6100
from 47 990 ₽
Technical specifications: NIP, g6100 Discreteness, g0,1 External calibration The size of the bowl / platform of the scales, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 6100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Support and rotary device OPU-2
Support and rotary device OPU-2
Technical specifications: Azimuth rotation angle from 0° to 360° with a reading of 0.1° The angle of rotation according to the angle of the place from minus 30° to plus 90° with a count of 0.1° The angle of rotation of the polarization plane from minus 95° to plus 95° with a count of 1° The installation height of the axis of the orientation mechanism is from 1.35 to 2.5 m. Note – The maximum height is determined when the rack is installed, the smooth lifting mechanism is fully extended and the legs are fully extended to the stop, extended at an angle of 30° to the axis of the azimuth mechanism. Smooth height adjustment of the axis of the orientation mechanism 0.25 m In terms of strength under climatic and mechanical influences, the rotary support device (OPU) complies with the norms of group 6 GOST 22261-94 Overall dimensions of the OPU - 1687x2500 (shown in the unfolded state at maximum height. The size Ø1687 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the OPU on a horizontal platform) Operating conditions of the OPU: ambient temperature from minus 50 to plus 60 ° C The mass of the OPU is 19.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Fischer coulometric Titrator
Fischer coulometric Titrator
from 690 000 ₽
The Fischer titrator is designed to measure the moisture content in non-aqueous media in substances that do not interact with the Fischer reagent, such as petroleum, petroleum products, oils (transformer, turbine, hydraulic, motor, etc.), organic solvents, etc. in accordance with GOST ISO 12937:2000, GOST 24614-81, GOST 33733-2016, GOST R 54284-2010, GOST R IEC 60814, GOST 14870-77, ASTM D 4928-00 (2010), ASTM D6304-07, ASTM D 1533-00, ASTM E 1064-05.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210S
Laboratory scales VLTE-210S
from 59 990 ₽
Technical characteristics: NIP, G210 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g on ±10; sv. 200g to 210g on ±15 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-8100
Laboratory scales VLTE-8100
from 49 990 ₽
Technical characteristics: NIP, G8100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 8100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Microassembly RB1S8KN009
Microassembly RB1S8KN009
Two-channel analog switch with signal summation function Designed for use in oscilloscopes with a bandwidth up to 350 MHz. Technical specifications: The value of the voltage between the outputs of the switch at load resistance RN = (50 ± 2.5) ohms and opening voltages UU1 = (2.0 ± 0.2) V and locking UU2 = (4.2 ± 0.2) V channels supplied alternately to the corresponding inputs (start 1, start 2) of the switches must be: in the absence of an input signal from minus 0.1 to plus 0.1 V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of the open channel (0.45 ± 0.1) V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of both open channels (0.45 ± 0.1) V
MNIPI
Minsk
Produced in: Belarus, Minsk
MS-10 Magnetic Structuroscope
MS-10 Magnetic Structuroscope
from 310 500 ₽
Distinctive features: - Non-destructive testing of strength, plasticity and viscosity of parts and structures made of ferromagnetic steels and cast iron according to the following standards: GOST 30415-96, OST 14-1-184-65, TU-14-1016-74 - Non-destructive testing of the depth and hardness of surface-hardened layers on steel and cast iron parts; - Quality control of low-temperature tempering of cutting and measuring tools, bearing steels; - Control of uniaxial elastic stresses; - Control of the uniformity of the properties of massive parts. Technical specifications: The range of coercive force of the material of the controlled products, A/cm, is 1.0...60. The limit of the permissible basic absolute error of measurements of the coercive force (Ns) on standard samples at a normal ambient temperature of 20 ± 5°C does not exceed the values of 0.1+0.04 Ns (Ns stands for the measured value of the coercive force of the standard sample). This error probability is provided with a gap between the converter and the surface of the controlled product not exceeding 0.5 mm. Basic version: The structroscope is powered by a battery. Extended version: It is possible to work on 220V/50Hz grid. The time of setting the operating mode after power on, min: no more than 2 Time of one measurement, sec: no more than 6 Continuous operation time (without recharging), h: at least 16 Internal memory: up to 512 series of 512 measurements each with the possibility to view the results Operating temperature range: -20°C to +40°C; Overall dimensions, (length x width x thickness), mm: electronic unit: 190x140x80 converter: 135x75x100 Weight, kg: the electronic unit with a battery: 2.3 ± 0.05 the converter: 1.3± 0.05 Basic version kit: Ia5.173.023 Electronic unit: 1 pc. Ia5.125.061 Converter: 1 pc. Ia8.896.121 Control sample of coercive force (plate PN-1): 1 pc. Ia8.896.122 Control sample of coercive force (plate PN-2): 1 pc. Bag-case: 1 pc. Charger: 1 pc. Ia2.778.042 RE Operating Manual: 1 copy. Ia2.778.042 FO Form: 1 copy. Ia2.778.042 MP Verification instructions: 1 copy. Extended version: Additionally, it can be equipped with a Bluetooth® module for communication with a PC and software for receiving and processing data. It can also be equipped with a small-sized converter.
Produced in: Moscow