Search

138 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 23
    Areas of use
    Loading...
  • 58
    Item names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • Additional
    Loading...
View:
138 products
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
Mass spectrometer for the analysis of solid-phase samples "Lumas GAS"
2 supp.
from 218.11 ₽
Technical specifications: Ionization method Glow discharge plasma Discharge gas Air Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is not limited Mass range 1-1000 m/z Detection limits 10-100 ppt Analysis time 1-3 min Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
TAN-1 pH meter
TAN-1 pH meter
The TAN-1 potentiometric pH meter analyzer is a representative of a new generation of pH meters with a touch control panel. It is designed to measure pH and redox potential (Eh) with simultaneous temperature measurement.
Produced in: Tomsk
ITAN pH meter/ionometer
ITAN pH meter/ionometer
ITAN pH meter/ionometer is a representative of a new generation of universal laboratory pH meters/ionometers with a touch control panel and unique functionality. A magnetic stirrer and a tripod with a foot for installing electrodes and a thermal sensor are built into the pH meter/ionometer housing.
Produced in: Tomsk
Analytical scales VL-84V-S
Analytical scales VL-84V-S
from 192 490 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range of the time of setting the readings, s, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-120C-O
Analytical scales VLA-120C-O
from 329 990 ₽
Technical specifications: NIP, g120 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of the permissible error of the scales during verification, ± mg, weighing intervals: from 0.01 g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, not more than 7 Adjusted weights 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-120C
Analytical scales VL-120C
from 174 990 ₽
Technical characteristics: NIP, G120 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 3;- standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg