PCU-1 Laboratory catalytic unit
PCU-1 Laboratory catalytic unit
The PCU-1 laboratory catalytic unit is designed to perform the following tasks: 1. Educational and scientific research of chemical processes; 2. Improvement of current industrial processes and development of new ones; 3. Studies of homogeneous and heterogeneous catalysts. The PCU-1 laboratory catalytic unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. Additionally, embedded equipment is designed to control the flow of raw materials and products, as well as data collection and processing. The unit can be subsequently modernized for new purposes. Main advantages: 1. A reliable and high-precision system of control and regulation of technological parameters; 2. Easy replacement of catalyst samples; 3. The possibility of conducting long-term tests in continuous mode; 4. The possibility of upgrading the unit for new purposes; 5. The possibility of conducting tests in flow and flow-circulation modes; 6. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
Hydrogen Generators GVCH-6
Hydrogen Generators GVCH-6
from 126 000 ₽
The GVCH-6 hydrogen generators are designed to power flame ionization detectors. They are equipped with a four-stage gas purification system. The hydrogen capacity is 6 liters/hour (100 ml/min). They have smooth adjustment and digital indication of the output pressure. Technical specifications The brand of produced hydrogen "A" according to GOST 3022-80 Purity of hydrogen in terms of dry gas is about 99.995% The concentration of water vapor at 20 ° C and 1.0 ati is not more than 20 ppm Total hydrogen capacity reduced to normal conditions is 6 l/h The range of the specified output pressure of hydrogen is from 1.5 to 6.0 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode is no more than 30 min Volume of bidistilled water to be filled is 1 l Consumption of bidistilled water is no more thann 0.01 l/hour Consumption of bidistilled water is 1.6 g/l of hydrogen Average power consumption in stationary mode is no more than 100 VA Maximum power consumption (at startup) is no more than 150 VA Overall dimensions of the generator, (width x depth x height) are not more than 180x450x435 mm The mass of the generator is not more than 11 kg Working conditions: ambient temperature, °C from +10 to +35 Power supply from single-phase mains: AC voltage, 220±10% and frequency, Hz 50 ± 1
Produced in: Moscow
META-CHROME AIR COMPRESSORS
META-CHROME AIR COMPRESSORS
The KOV-4 type air compressor is designed to supply flame detectors of gas chromatographs with air. Technical specifications: Capacity, at least, l/min 3 Outlet air pressure, 0.25+5 MPa% Pressure stability at constant flow rate, not more than 0.0007 MPa Engine power consumption, max, VA 100 Receiver volume, l 9 Noise level, no more, 60 dBa Weight, not more than, kg 19 Overall dimensions (width×depth×height), not more than, mm 235×755×440 Single-phase mains voltage 220 V, 50 Hz
Produced in: Yoshkar-Ola, Mari El
DIGITAL MULTICHANNEL LEAK
DIGITAL MULTICHANNEL LEAK
The Meta-chrome digital gas flow meter is designed to maintain a given pressure and the ratio of the amount of gases (in the flow mode) or gas flow (in the intake mode) in vacuum installations with automatic and manual control. technical specifications The number of control channels is 2 (or more on request). The maximum flow rate for each of the channels is 700 cm3/min. The possibility of using gas correction coefficients, the most commonly used gases are listed in the leaker database. The accuracy of maintaining a given proportion of gases is 5%. The accuracy of maintaining the specified gas flow rates is 3%. Input pressures from 1 to 4 atm. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption (without a personal computer), no more than — 30 VA. Overall dimensions (width × depth × height), no more than 165×350×215 mm. Weight, not more than 5.5 kg.
Produced in: Yoshkar-Ola, Mari El
Pure nitrogen generator GCHA-180
Pure nitrogen generator GCHA-180
from 448 800 ₽
GCHA-180 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than, l/h, 180 (3.0 l/min) Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 4200 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 36 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
Generator of Pure Nitrogen and Zero Air GCHA-15D-40V-K
Generator of Pure Nitrogen and Zero Air GCHA-15D-40V-K
from 450 000 ₽
The generator is designed to produce nitrogen of the highest purity and zero air in laboratories. Differences from the GCHA-15D-60V: lower air performance; the presence of a built-in oil-free compressor ensures complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor is 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol. (0.1 ppm) Maximum nitrogen capacity is not less than 15 liters/hour (250 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol. (7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than, 0.00001% vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 40 liters/hour (670 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift operation is no more than 45 min Noise level generated by the compressor is no more than 50 dB Power consumption is not more than 300 VA Overall dimensions, (width x depth x height) are not more than 230x470x510 mm Weight is not more than 27 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen generator GA-200
Nitrogen generator GA-200
from 282 000 ₽
Nitrogen generators are designed to create an inert atmosphere, fill low-pressure tanks, "rinse" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.6 Volume fraction of oxygen is not more than, % vol. 0,4 Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity is at least 200 (3.33 l/min), l/h Maximum nitrogen outlet pressure is not less than 3.5 ati The time of setting the operating mode for single-shift operation is no more than 30 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 1200 (20 l/min) Power consumption is not more than, VA, 100 Overall dimensions (width x depth x height) are not more than, mm, 230x525x510; Weight is not more than 26 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
Water purification in the device is carried out by passing it through a composition of deionization resins and sorbents. Resins and sorbents are located in filter elements placed in a replaceable cassette. The distilled water to be cleaned is poured into the feed tank, the filler neck of which is placed on the upper plane of the device and hermetically sealed with a screw cap. Technical specifications: The specific conductivity of the resulting water, not more than, mkSxcm 0.20 Capacity, at least, l/h 6 Operating time of the replaceable cassette (total volume of purified water), not less than 700 liters Volume of refilled distilled water, l. 1 Power consumption, not more than, VA 20 Overall dimensions (width×depth×height), mm 180×450×380
Produced in: Yoshkar-Ola, Mari El
Air Purification Units BOV-1
Air Purification Units BOV-1
from 79 200 ₽
They are designed for purification of nitrogen (BOV-1A) and air (BOV-1) from hydrocarbons Technical specifications Inlet air pressure is not more than 825 ± 5% kPa (8 ati) Output pressure control limits is from 0 to 413 kPa (from 0 to 4.0 ati) Minimum required excess of inlet pressure over outlet pressure is not less than 103 kPa(1 ati) Maximum permissible air flow is not more than 1.0 l/min Concentration of hydrocarbons at maximum flow rate in the outlet air is no more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Instability of the output pressure when the flow rate changes from 0 to the maximum value is not worse than ± 7 kPa Instability of the output pressure when the input pressure changes by ± 100 kPa is not worse than ± 7 Ready time after switching on at a flow rate not exceeding the maximum value is no more than 30 min Power consumption is not more than 50 VA Overall dimensions, (width x depth x height) are no more than 185x310x310 mm Weight is not more than 5.0 kg Working conditions: ambient temperature, °C, from +10 to +35 relative humidity of the ambient air, %, no more, at 35 ° C 80 electric power from a single-phase AC network with a voltage of 220 +10% -15% and a frequency of 50 ± 1 Hz
Produced in: Moscow
HYDROGEN GENERATOR (HW) 7, 12, 16, 25 LITERS
HYDROGEN GENERATOR (HW) 7, 12, 16, 25 LITERS
The hydrogen generator is equipped with its own microprocessor, with which you can control the operating modes of the device. It is microprocessor control that determines the autonomy of the device. Moreover, this allows you to control the basic and technical parameters of the device (pressure, flow rate, level of water poured into the tank, tightness of gas lines, electrolyzer current). For the manufacture of gas lines, exclusively inert materials are used. Technical specifications:

The device is equipped with a four-button keyboard, which is used to set parameters and control. The generator can operate in continuous mode for a long time. For refueling, especially pure or double-distilled water is used, and refueling can be done without turning off the device, on the go. Their advantage is that they significantly reduce, or even completely eliminate, the use of bottled gases to power chromatographs and gas analyzers. For nutrition, mainly double-distilled water is used, the quality of which must be no lower than grade B water according to OST 11.029.003–80, and the electrical resistivity must be no less than 1 Mohm x cm.

The devices operate from a single-phase AC electrical network with voltage from 187 to 242 W, frequency (50±1) Hz. Maximum safety of devices is achieved due to the absence of such a supply of substance in them, which could fill a chromatograph or laboratory in a short period of time. The performance of the device eliminates the occurrence of explosive situations, so the generator is considered safe to use.
Produced in: Yoshkar-Ola, Mari El