Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-89, B5-89/1
Power supply B5-89, B5-89/1
Technical specifications: Indicator name, unit of measurement, Indicator value, B5-89, B5-89/1 The range of the output voltage setting, the limits of the absolute error of the output voltage setting:- basic error, In; - in operating conditions, In, from 0 to 30.0 ± 0.2± 0.3, from 0 to 100.0 ± 0.3± 0.45 The range of the output current setting, the limits of the absolute error of the output current setting:- basic error, A; - in operating conditions, A, from 0 to 10.0 ± 0.2± 0.3, from 0 to 3.0 ± 0.1± 0.15 Instability of the output voltage when the supply voltage changes by ± 10% of the nominal value in the voltage stabilization mode, %, ± 0.05, no more, Instability of the output current when the supply voltage changes by ± 10% of the nominal value in the current stabilization mode, %, ± 0.2, no more, Instability of the output voltage when the load current changes at the output terminals of power supplies in voltage stabilization mode, %, ± 1, no more, Instability of the output current when the load voltage changes in the current stabilization mode at minimum load currents, %, ± 5, no more, Instability of the output current when the load voltage changes in the current stabilization mode at maximum load currents, %, ± 0.5, no more, Output voltage ripple in voltage stabilization mode, mV, 1.0, no more, Output current ripple in current stabilization mode, %, 1, no more, Instability of the output voltage from time, V, ± 0.5, ± 1.0 Instability of the output current from time, A, ± 0.3, ± 0.2 AC power supply: - voltage, V; - frequency, Hz, 230 ± 2350 ± 0.5, Weight, kg, 13.0, no more, Overall dimensions, mm, 384x301x169
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-131A
Low-frequency signal generator G3-131A
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 2 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min Signal amplitude ±5 V at 600 ohm load ±10 V without load Limits for adjusting the output signal level from 1 mV to 3.75 V (scr) at a load of 600 ohms from 2 mV to 7.5 V (scz) without load Signal level unevenness ± 2% at frequencies from 20 Hz to 200 kHz relative to 1 kHz ± 5% at frequencies from 200 kHz to 2 MHz Harmonic coefficient ± 0.3% at frequencies from 2 to 20 Hz ± 0.2% at frequencies from 20 Hz to 100 kHz ±1% at frequencies from 100 kHz to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2
MNIPI
Minsk
Produced in: Belarus, Minsk
KRONA-12 Electric spark flaw detector
KRONA-12 Electric spark flaw detector
from 430 000 ₽
The flaw detector allows continuous monitoring of polymer, epoxy and enamel coatings of pipelines with a diameter from 219 to 1420 mm and selective control of polymer, epoxy, enamel and bitumen coatings of pipelines of any diameter. The flaw detector provides detection of local through defects of insulation coatings of pipelines with a dry surface. The flaw detector allows for continuous monitoring The flaw detector uses an electric spark control method. The flaw detector is designed to work at: - ambient temperature, °C: from minus 30 to plus 50; - relative humidity at a temperature of +25°C, %: 98; - atmospheric pressure, kPa: from 84.0 to 106.7. Technical specifications. Test voltage, kV: up to 40 Minimum diameter of detected defects, mm: 0.6±0.2 Operating temperature range, °C: -30...+50 Power supply -from the built-in 12V battery -from an external DC power supply current with a voltage of 12 V Continuous operation time, h: 8 Operating mode setting time, min: 1 Overall dimensions, mm, no more: - control and monitoring unit 200 x 158 x 91 - high voltage transformer 410x f90 Weight, kg, no more,: - control and monitoring unit 2.5 - high voltage transformer 1.5 Defect alarm light and sound The kit includes: Bag Suitcase Battery charger Earthing device Electronic Magnet Unit Probes for continuous monitoring- 5 pcs 0 – 400 mm; 1 – 650 mm; 2 – 735 mm; 3 – 840 mm; 4 – 980 mm. Probes for local control - 3 pcs VT-1 High voltage transformer Pin Probe extension Holder Bushing Nipple - 4pcs set of documentation (passport, manual, calibration)
Produced in: Moscow
Workplace of Classic series
Workplace of Classic series
1 supp.
When lining up, Classic series desktops fit snugly together, without forming cracks and gaps. The universal design of the table frame allows you to further equip the workplace with a suspended pedestal and other necessary equipment. Additionally, work tables of Classic series can be equipped with a number of modules: electrical and perforated panels, overhead and local lighting, shelves for equipment, hanging cabinets, corner tables, etc.
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Picoammeter A2-4
Picoammeter A2-4
System meter of small currents. The device allows to make measurements in almost the entire range of currents. The picoammeter is characterized by high performance, which is important for its use as part of automated measuring systems. Technical specifications: Current measuring range 1x10-14 - 1x10-2 A Error for the range 10-11, 10-10 ±[0.5+0.025(lk/lx-1)]% for the range 10-9, 10-8 ±[0.25+0.01(lk/lx-1)]% for the range 10-7, 10-6,10-5, 10-4,10-3, 10-2 ±[0,1+0,01( lk/lx-1)]% The time of setting the readings is 2x10-2 - 2x10-5 s Supply voltage 230 (±20) V, frequency 50 (± 0.5) Hz Power consumption 10 VA Overall dimensions (HxWxD) 105x284x366 mm Weight 3.5 kg Operating temperature 5 - 40 °C Humidity 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk