Search

46 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 10
    Applying
  • 22
    Names
    Loading...
  • 4
    Manufacturer
  • 4
    Made in
  • Additional
View:
46 products
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Connecting device UP-4
Connecting device UP-4
Technical specifications: Residual capacity when working with immitance meters < 1 pF Residual inductance when working with immitance meters < 0.5 µgn Residual resistance when working with immitance meters < 0.05 ohms Maximum input voltage ±60 V Distance between measuring contacts from 0 to 6 mm Length 1050 mm Weight 160 g
MNIPI
Minsk
Produced in: Belarus, Minsk
Generators G4-221, G4-221/1
Generators G4-221, G4-221/1
Technical specifications: Frequency range of sinusoidal waveforms, 0.1 Hz - 17 MHz Frequency range of rectangular-shaped signals, 0.1 Hz - 1 MHz Frequency setting discreteness, ±(0.012 + 0.0001 f), f in Hz Frequency instability in 15 minutes, no more than ± 1•10-5 Smooth signal attenuation, 40 dB Stepwise signal attenuation, 20, 40, 60 dB
MNIPI
Minsk
Produced in: Belarus, Minsk
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Power supply B5-78
Power supply B5-78
Technical specifications: B5-78 (15 V, 3 A); B5-78/1 (30 V, 2 A); B5-78/2 (50 V, 1 A); B5-78/4 (20 V, 1.5 A); B5-78/6 (30 V, 4 A); B5-78/7 (50 B, 2.5 A) Voltage measurement error: ±0.3 V Current measurement error: ±(0.04–0.06) A Voltage instability when the load current changes 0.03% Instability of the current when the voltage changes at a load of 0.2% Voltage ripple 0.5–1 mV Current ripple 0.1% Power consumption 90 - 320 VA Two 3-digit indicators (voltage, current) Adjustments are rough, smooth Dimensions 115x185x360 mm Weight: 3.7 kg (B5-78, B5-78/1, B5-78/2) 3 kg (B5-78/4) 5.5 kg (B5-78/6, B5-78/7) Power supply ~220 V A
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-132
Low-frequency signal generator G3-132
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 0.1 Hz to 10 MHz Frequency setting error ±0.02% Frequency instability ±0.01% in 15 min Signal amplitude ± 2.5 V at 50 ohm load ±5 V without load Limits of adjustment of the output signal level from 2 mV to 1.85 V (skz) at a load of 50 ohms from 4 mV to 3.75 V (scz) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz relative to 1 kHz ± 2% at frequencies from 10 Hz to 1 MHz ±10% at frequencies from 1 to 10 MHz Harmonic coefficient ± 0.2% at frequencies from 10 to 100 Hz ±0.07% at frequencies from 100 Hz to 20 kHz ± 0.2% at frequencies from 20 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 10 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V In the frequency range from 0.1 Hz to 2 MHz, the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-82
Voltmeter V7-82
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± 0.01% AC voltage , Measuring range, 1 mV - 700 V Measurement error, ± 0.4% Frequency range, 20 Hz- 1 MHz Direct current , Measuring range, 0.2 µA - 10 A Measurement error, ± 0.15%
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test installations UPU-21, UPU-21/2
High-voltage test installations UPU-21, UPU-21/2
Technical specifications: Output constant voltage, 0 - 3 kV; 0 - 10 kV Output AC voltage, 0 - 3 kV; 0 - 10 kV Measurement of leakage current, from 0 to 100 Ma The amplitude value of the output voltage ripples relative to the set voltage at a load current of 1 mA, ≤ 5% The error of setting the output voltage, ≤ 4% Protection tripping current, up to 50 mA Output power, 500W Overall dimensions (HxWxD), 280x480x475 mm Weight, 36 kg Operating conditions , Operating temperature, from +5 to + 40 °C Humidity, 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
Pulse DC power supply B5-71/5-PRO
Pulse DC power supply B5-71/5-PRO
Regulated switching power supplies with highly stable output characteristics Digital display of set and actual value, voltage and current (4 digits, LED) Electronic load switching on/off Protection against overload, short circuit, overheating and reverse polarity Low ripple output voltage less than 2mV Low ripple output current less than 5mA Minimum discreteness of setting output voltage and current 0.007/0.005 Operating modes: stabilization U and I, dynamic load RS-232 interface
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
PKE-A Energy Tester
PKE-A Energy Tester
The devices are designed for: measurements and registration of the main indicators of the quality of electrical energy established by GOST 32144-2013 (GOST R 54149-2010) with registration of protocols according to GOST 33073-2014; measurements and registration of the main parameters of electrical energy in single-phase and three-phase electrical networks (including the effective values of voltages and currents with sinusoidal and distorted curves; active, reactive and full electrical power); measurements of parameters of secondary circuits (load capacity of measuring transformers and voltage drop) in electric energy metering systems and electric energy losses in power supply lines. functional test and verification of connection of meters of active and reactive power and energy, energy measuring converters of voltage, current at the places of their operation; functional test and verification of the connection of single-phase and three-phase electric energy meters without breaking current circuits to detect theft of electricity; measurements of electricity losses in the power supply line. The PKE-A energy tester provides registration with subsequent transfer to a personal computer (PC) of statistical data on the PKE: Values of the PCE according to GOST 30804.4.30 (GOST P 51317.4.30) and GOST 30804.4.7 (GOST P 51317.4.7) with a registration depth of 512 days; Values and durations of voltage dips and overvoltages; Values of the short-term dose of flicker; Parameters of the electrical network and vector diagrams with the depth of registration: - 24 hours for averaging time of 3 s, - 200 days for averaging time of 10 min. The program "Energy Monitoring ES" provides the formation of quality control protocols in the form of GOST 33073-2014.
Marsenergo
Saint Petersburg
Produced in: Saint Petersburg
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-20
Immitance meter E7-20
Technical specifications: Wide frequency range 25 Hz–1 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.04 – 1) V RS-232C interface Mathematical processing of measurements Dimensions, weight: 127x298x300 mm, 4 kg Power supply ~220 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk