PU Desktop laboratory catalytic unit
PU Desktop laboratory catalytic unit
The PU desktop laboratory unit is an automated installation based on a mini–reactor with a fixed layer that has a volume of up to 1.5 cm3. The PU desktop laboratory unit is designed to perform kinetic studies, evaluate the properties of catalysts, model catalytic processes, test the stability of catalysts and sorbents. For maximum compliance with the customer's requests, the installation has a modular design with the possibility of adding new options. Main advantages: 1. Compactness; 2. Real-time parameter monitoring; 3. Easy maintenance; 4. Operation safety; 5. User-friendly interface. Applied tasks 1. Hydrogenation/dehydrogenation processes of hydrocarbons; 2. Fischer-Tropsch synthesis; 3. Catalytic cracking and isomerization; 4. Reforming of natural gases; 5. Hydrogenation processes; 6. Catalytic oxidation; 7. Hydrotreating processes. Basic equipment 1. Gas supply unit 2. Reactor unit 3. Separation unit 4. Sampling unit 5. Unit for measuring the volume of the outgoing gas 6. Control unit
Produced in: Rostov region, Novocherkassk
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 186 000 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
PCU-1 Laboratory catalytic unit
PCU-1 Laboratory catalytic unit
The PCU-1 laboratory catalytic unit is designed to perform the following tasks: 1. Educational and scientific research of chemical processes; 2. Improvement of current industrial processes and development of new ones; 3. Studies of homogeneous and heterogeneous catalysts. The PCU-1 laboratory catalytic unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. Additionally, embedded equipment is designed to control the flow of raw materials and products, as well as data collection and processing. The unit can be subsequently modernized for new purposes. Main advantages: 1. A reliable and high-precision system of control and regulation of technological parameters; 2. Easy replacement of catalyst samples; 3. The possibility of conducting long-term tests in continuous mode; 4. The possibility of upgrading the unit for new purposes; 5. The possibility of conducting tests in flow and flow-circulation modes; 6. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 297 600 ₽
The device is equipped with an automatic regeneration system of fine filters, which reduces the maintenance of the device to a minimum. In terms of the totality of technical characteristics and ease of operation, it has no equal among similar laboratory hydrogen generators. The hydrogen capacity is 12 liters/hour (200 ml/min). Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1 atm is not more than 5ppm Total hydrogen capacity, reduced to normal conditions is not less than 12 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 180 VA maximum (at startup) is no more than 220 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage 220 V(+10 -15)% and frequency 50 +1 Hz The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
AIR GENERATOR
AIR GENERATOR
In addition to air compressors of the type "KOV-4", a pure air generator of the type "GCHV" is produced. Our equipment undergoes thorough quality control, which is confirmed by certificates of conformity. The device is used to provide clean air supply to gas analyzers and flame ionization detectors of chromatographs. Technical specifications: Air capacity reduced to normal conditions, l/min, not less than 2.0 Outlet air pressure, 2.5 atm Outlet pressure stability, no more than 0.05 atm Output concentration of hydrocarbons, ppm, not more than 0.1 Concentration of water vapor at 200C and 100kPa, ppm, no more than 10 The value of the power consumption, not more than 200 VA Dimensions (width×depth×height), mm 210×440×360 Weight, not more than, kg 11
Produced in: Yoshkar-Ola, Mari El
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
from 450 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol. (0.1 ppm) Maximum nitrogen capacity is not less than 21 liters/hour (350 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol.(7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 72 liters/hour (1200 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6.0 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x525x510 mm Weight is not more than 28 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
AUTOSAMPLER "NT3100A": FUNCTIONS
AUTOSAMPLER "NT3100A": FUNCTIONS
The autosampler is used to automate the process of entering samples of liquid consistency into chromatographs of the line "Kristallux", "Crystal", series "Color", LHM. The autosampler is compact in size and easy to operate. The device is compatible with different models of chromatographs and is suitable for many studies. When the device is working with the Crystallux series chromatographs, the autosampler can be controlled using the chromatographic equipment software, while no additional programs are required.
Produced in: Yoshkar-Ola, Mari El
Dry Air Compressor KSV-6/500
Dry Air Compressor KSV-6/500
The oil-free compressor is designed to supply air to laboratory nitrogen and oxygen generators, purge optical systems of laboratory devices with dry air, etc. A feature of the device is the presence of a built-in automatic regeneration system of the air drying filter, which frees the user from routine maintenance. Small dimensions, low noise level, lack of maintenance work allow the compressor to be placed in the laboratory room and make working with it easy. Technical specifications Rated output, reduced to normal conditions is 9.0 l/min Maximum output, reduced to normal conditions is 12.0 l/min The range of the set output pressure is from 1.0 to 6.0 ati Output pressure stability at constant flow rate is not worse than ± 0.2 ati Stability of the output pressure when the flow rate changes from 0.5 to the maximum value is not worse than ± 0.4 ati The dew point of the outlet air at an ambient temperature of 20 ° C and rated capacity is not higher than minus 30 ° C The dew point of the outlet air at an ambient temperature of 20 ° C and maximum performance is not higher than minus 15 ° C Volume of the built-in receiver is 6 l The noise level of the device is not more than 50 db Ready time after switching on is no more than 10 min Power consumption is not more than 600 VA Overall dimensions of the device (width x depth x height)are not more than 230x580x530 mm Weight of the device is not more than 28 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow