Air Purification Units BOV-1
Air Purification Units BOV-1
from 79 200 ₽
They are designed for purification of nitrogen (BOV-1A) and air (BOV-1) from hydrocarbons Technical specifications Inlet air pressure is not more than 825 ± 5% kPa (8 ati) Output pressure control limits is from 0 to 413 kPa (from 0 to 4.0 ati) Minimum required excess of inlet pressure over outlet pressure is not less than 103 kPa(1 ati) Maximum permissible air flow is not more than 1.0 l/min Concentration of hydrocarbons at maximum flow rate in the outlet air is no more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Instability of the output pressure when the flow rate changes from 0 to the maximum value is not worse than ± 7 kPa Instability of the output pressure when the input pressure changes by ± 100 kPa is not worse than ± 7 Ready time after switching on at a flow rate not exceeding the maximum value is no more than 30 min Power consumption is not more than 50 VA Overall dimensions, (width x depth x height) are no more than 185x310x310 mm Weight is not more than 5.0 kg Working conditions: ambient temperature, °C, from +10 to +35 relative humidity of the ambient air, %, no more, at 35 ° C 80 electric power from a single-phase AC network with a voltage of 220 +10% -15% and a frequency of 50 ± 1 Hz
Produced in: Moscow
HYDROGEN GENERATOR (HW) 7, 12, 16, 25 LITERS
HYDROGEN GENERATOR (HW) 7, 12, 16, 25 LITERS
The hydrogen generator is equipped with its own microprocessor, with which you can control the operating modes of the device. It is microprocessor control that determines the autonomy of the device. Moreover, this allows you to control the basic and technical parameters of the device (pressure, flow rate, level of water poured into the tank, tightness of gas lines, electrolyzer current). For the manufacture of gas lines, exclusively inert materials are used. Technical specifications:

The device is equipped with a four-button keyboard, which is used to set parameters and control. The generator can operate in continuous mode for a long time. For refueling, especially pure or double-distilled water is used, and refueling can be done without turning off the device, on the go. Their advantage is that they significantly reduce, or even completely eliminate, the use of bottled gases to power chromatographs and gas analyzers. For nutrition, mainly double-distilled water is used, the quality of which must be no lower than grade B water according to OST 11.029.003–80, and the electrical resistivity must be no less than 1 Mohm x cm.

The devices operate from a single-phase AC electrical network with voltage from 187 to 242 W, frequency (50±1) Hz. Maximum safety of devices is achieved due to the absence of such a supply of substance in them, which could fill a chromatograph or laboratory in a short period of time. The performance of the device eliminates the occurrence of explosive situations, so the generator is considered safe to use.
Produced in: Yoshkar-Ola, Mari El
Gas chromatograph Crystallux-4000m
Gas chromatograph Crystallux-4000m
The gas chromatograph "Kristallux-4000M" is fully automated, starting from sample input and ending with chromatographic information processing, including the functions of automatic temperature control of thermostats, flow rates and pressure of the carrier gas (EUPG system), auxiliary gases, automatic ignition of detectors, flame burning control during operation, measurement of detector signals using Gorenje 24-bit ADC. Technical specifications: The detection limit of PID is 1,1x10-12 gS/s for h-hydrocarbons 1,1x10-12 gS/s for propane. The detection limit of DTP1.7x10-14 g/s for lindane 3.9x10`15 g/s for lindane (micro-ED) The detection limit of EZD1x10`13 grus for phosphorus in metaphos 8x10`13 g5/s for sulfur in metaphos or hydrogen sulfide PFD detection limit 1.5x10`14 g/s for phosphorus in metaphos 3x10`13 GM/s for nitrogen in azobenzene Detection limit of TID2x10`10 g/ml by hydrogen The detection limit of TcD is 5x10`13 g/s for benzene The detection limit of the FEED is 3x10`13 g/s for carbon in methane 3x10`13 g/s for carbon in methane Detection limit GID500:1 (M7-801) with the introduction of 1x10`12 g / ml of octafluoroaphthalene The signal-to-noise ratio of MSD 1500:1 (Maestro-oMS) when entering 1x10`12 g / ml of octafluoroaphthalene Linear dynamic range of PID x1*107 Linear dynamic range DTP1*108 The volume of the column thermostat is 14 (19)l The temperature of the column Current.Wednesday +3 °C to +400 °C (by special order up to 450 °C) (by special order from -10°C with use. cold. ust-ki)(by special order from -100 °C. with use. liquid, no.) The discreteness of the temperature setting is 0, ° C Temperature stability 0.01 °C Temperature programming speed 0t 0.1 to 125 °C/min (by special order up to 150 °C/min) The number of isotherms is not less than 30 The cooling rate of the column thermostat is from 400 to 50 °C3.3 min. The maximum temperature of the detector and evaporator is 450 °C Carrier gas consumption from 0 to 100 ml/min.(by special order up to 500 ml/min.) Carrier gas pressure (for capillary column) from 0 to 0.40 Mpa (by special order up to 1 MPa) The maximum inlet gas pressure on a special order is 0.5 MPA 1.25 MPA Hydrogen consumption 0-500 Air consumption 0-1000 Overall dimensions (width x depth x height) 550%500*500 mm Weight 39 kg Electric power supply from AC mains voltage (220.2) V, frequency (50 +1) Hz The maximum power consumption (in steady-state mode) is 900 VA.
Produced in: Yoshkar-Ola, Mari El
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 297 600 ₽
Designed to power flame ionization detectors. It can be used as a carrier gas source. The hydrogen capacity is 12 liters/hour (200 ml/min). Equipped with a 5-stage gas purification system, including a reactor to remove traces of oxygen. It has smooth adjustment and digital pressure indication. Technical specifications The brand of produced hydrogen "A" according to GOST 3022-80 Purity of hydrogen in terms of dry gas is about 99.999% Concentration of water vapor at 20 °C and 1.0 ati is no more than 5 ppm Total hydrogen capacity reduced to normal conditions is 12 l/h The range of the specified output pressure of hydrogen is from 1.5 to 6.0 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode is no more than 30 minutes Volume of bidistilled water to be filled is 1 l Consumption of bidistilled water is no more than 0.02 l/hour Consumption of bidistilled water is 1.6 g/l of hydrogen Average power consumption in stationary mode is no more than 150 VA Maximum power consumption (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 180x450x435 mm Generator weight is not more than 11 kg Working conditions: ambient temperature, °C from +10 to +35 Power supply from single-phase AC mains voltage, 220 ±10% and frequency, Hz 50 ± 1
Produced in: Moscow
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 186 000 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
NV-1500 LX-O Table for chromatograph (1500×700×850)
NV-1500 LX-O Table for chromatograph (1500×700×850)
from 20 657 ₽
The NV-1500 LX-O are specialized laboratory tables on a reinforced metal frame with a countertop width of 1500 mm. They are designed to accommodate heavy instruments, such as chromatographs or other analytical equipment. In the upper right corner of the table there is an electric panel with two sockets. Both sockets with grounding and shutters are designed for current up to 16 A and voltage up to 250 V. Working surface material: porcelain tile. It is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular types of countertops for laboratory furniture. The tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled: 1500×700×850 mm. It is designed for standing work.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Nitrogen generator GA-400-N
Nitrogen generator GA-400-N
from 414 000 ₽
The GA-400-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-400 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-400, the GA-400-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than 99.5% by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol.(20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati, is not less than 400 l/hour (6.66 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Factory setting of the maximum pressure value in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 35 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
METERING VALVE FOR GAS SAMPLES
METERING VALVE FOR GAS SAMPLES
The metering valve for the introduction of gas samples is designed for the introduction of gas under excessive pressure into the chromatograph. Cranes differ in the number of moves (4, 6, 8, 10, 12) and have two provisions "Selection" — "Analysis". In addition to dosing, cranes can be used to switch chromatographic columns, elements of gas circuits, etc. The tap can be installed either on the side panel of the chromatograph, or directly into the analytical module instead of, or together with the evaporator of the chromatograph, while it is used as a back-purge tap or for hot sample entry. Additionally, the tap for hot entry can be equipped with heated pipelines. technical specifications The dose volume is from 0.25 to 5.0 ml (at the request of the consumer, the dose volume can be increased to 10 ml and reduced to 0.1 ml). The maximum temperature of the tap is no more than 160 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle — depending on the number of strokes.
Produced in: Yoshkar-Ola, Mari El
Nitrogen generator GA-200-N
Nitrogen generator GA-200-N
from 306 000 ₽
The GA-200-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-200 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-200, the GA-200-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.4 Volume fraction of oxygen is not more than, % vol. 0.6 Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati is at least 200 l/hour (3.33 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 1800 l/hour(30 l/min) Factory setting of the maximum pressure in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than, VA, 100 Overall dimensions (width x depth x height) are not more than, mm, 230x525x510; Weight is not more than 27 kg. Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Thermal Conductivity Detector(accident)
Thermal Conductivity Detector(accident)
It is used to determine hydrogen, oxygen, CO and combustible hydrocarbon gases, and its sensitivity to these compounds is higher than the sensitivity of an accident. The most widespread TCD was obtained for the analysis of hydrogen and oxygen, tk. its sensitivity to them is almost an order of magnitude higher than that of an accident. The principle of operation is based on fixing the thermal effect of catalytic combustion of the sample on the surface of the platinum filament. Technical characteristic: 1.8*10`10 g/ml of hydrogen
Produced in: Yoshkar-Ola, Mari El
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El