Atom Fast 77100 - scintillation radiation detector and application with android
Atom Fast 77100 - scintillation radiation detector and application with android
from 45 000 ₽
1 supp.
Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device Full charge time The time to fully charge the built-in battery from a PC USB port or charger is no more than 4 hours. Operating time from a fully charged built-in battery under natural radiation conditions without the use of sound/vibration alarms is at least 2 weeks. Maximum counting speed (imp/sec) is not less than 10,000 imp/s (600,000 imp/min). Device weight (g) no more than 60 Note Atom Fast can withstand irradiation with a dose rate of up to 2000 R/h for 2 s without damage and fully restores functionality after cessation of irradiation in no more than 2 s. Operating temperature range from -40 to +40 degrees. C (for the “new” detection block edition from the fall of 2019, the range is from -20 to +40). When the temperature rises above +40 degrees. C, the device will warn the user about this with the sound of a two-tone siren repeating once a minute. With a further increase in temperature, correct operation of the device is not guaranteed. Energy range of recorded photon radiation (keV) is not less than 60 - 3000. Working size of scintillation detector (mm) 7.5*7.5*100 Contents of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter attachment Atom Fast 77100 - 1 pc. Packing box 1 pc. Carrying case - 1 pc.
Produced in: Moscow, Troitsk
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8850 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Technical specifications Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device. The sensitivity anisotropy according to Cs137 (%) is not more than 30 The full charge time of the built-in battery from the USB port of the PC or charger is no more than 4 hours. Operating time Continuous operation from a fully charged built-in battery in conditions of natural radiation background: - without the use of sound/vibration alarm for at least 2 months; - without using wireless communication and sound/vibration alarm for at least 4 months. Maximum counting speed (imp/sec) 10000 The weight of the device (g) is not more than 50 Note The Atom Fast 8850 can use a cylindrical crystal with a diameter of 10 mm and a height of 40 mm without prior notice. The energy range of the recorded photon radiation (keV) is not less than 60 - 3000 keV Working size of the scintillation detector (mm) 8*8*50 The scope of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter set—top box Atom Fast - 1 pc. Packing box 1 pc. Carrying case — 1 pc.
Produced in: Moscow, Troitsk
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device Full charge time The time to fully charge the built-in battery from a PC USB port or charger is no more than 4 hours. Operating time from a fully charged built-in battery under natural radiation conditions without the use of wireless communication and sound/vibration alarms is at least 4 months Maximum counting speed (imp/sec) is not less than 10,000 imp/s (600,000 imp/min). Device weight (g) no more than 50
Note Atom Fast can withstand irradiation with a dose rate of up to 2000 R/h for 2 s without damage and fully restores functionality after cessation of irradiation in no more than 2 s. Operating temperature range from -40 to +40 degrees. C (for the “new” detection block edition from the fall of 2019, the range is from -20 to +40). When the temperature rises above +40 degrees. C, the device will warn the user about this with the sound of a two-tone siren repeating once a minute. With a further increase in temperature, correct operation of the device is not guaranteed. Energy range of detected photon radiation (keV) Working size of scintillation detector (mm) 8*8*16

Contents of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter attachment Atom Fast 8816 - 1 pc. Packing box 1 pc. Carrying case - 1 pc.
Produced in: Moscow, Troitsk