It is intended for sampling, conducting chemical, biological, microbiological analyses, in small volumes of chemical reactions. It is made of transparent polystyrene, hermetically sealed with a blue or red screw polypropylene lid.
The walls of the tubes are covered with a dry clot formation activator to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample.
Material for research............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology
Centrifugation................................ 1000 - 1500 g - 10 minutes
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation.
Research material............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology, serology
Centrifugation................................ 1500 g - 10 minutes
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. The gel forms a stable barrier between the serum and the shaped elements during centrifugation.
Research material............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology, serology
Centrifugation................................ 1500 g - 10 minutes
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9.
Material for research............... citrate plasma, blood
Scope of application............................ coagulation study
Centrifugation................................ 2000 - 2500 g - 10-15 minutes
The walls of the tubes are covered with a dry clot formation activator to accelerate blood clotting. Mixing blood with it does not affect the result of tests. The acceleration of the blood clotting process significantly reduces the preparation time of the biological sample.
Research material............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology
Centrifugation................................ 1000 - 1500 g - 10 minutes
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests.
Material for research............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology, serology
Centrifugation................................ 1000 - 1500 g - 10 minutes
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection.
Material for research............... blood serum
Scope of application............................ serum research in biochemistry, immunology
Centrifugation.............................. 1500-2000 g - 10 minutes
Designed for centrifugation of biological and other liquids. The tube is conical graduated with a window for recording and a screw cap. The calibration on the test tube is applied with white paint, resistant to erasure. The test tube is made of polypropylene, which allows it to be autoclaved in standard mode. Relative centrifugal acceleration9000d
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection.
Research material............... blood serum
Scope of application............................ serum research in biochemistry, immunology
Centrifugation.............................. 1500-2000 g - 10 minutes
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies.
Material for research............... stabilized EDTA whole blood /EDTA plasma.
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests.
Material for research............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology, serology
Centrifugation................................ 1000 - 1500 g - 10 minutes
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies.
Material for research............... stabilized EDTA whole blood /EDTA plasma.
Scope of application............................ hematological examination of whole blood
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies.
Material for research............... EDTA-blood, plasma
Scope of application............................ hematological examination of whole blood
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection.
Material for research............... blood serum
Scope of application............................ serum research in biochemistry, immunology
Centrifugation.............................. 1500-2000 g - 10 minutes
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests.
Material for research............... blood serum
Scope of application............................ blood serum research in biochemistry, immunology, serology
Centrifugation................................ 1000 - 1500 g - 10 minutes
The test tube is intended for the selection, storage and transportation of biomaterial samples for further diagnostic studies in clinical laboratories. Made of polystyrene. No traffic jam. It has a circular calibration to determine the approximate volume 0,5-1,0-2,5-5,0-10,0 ml.