General purpose exhaust cabinet LAB-PRO SHV 90.84.230 SS
General purpose exhaust cabinet LAB-PRO SHV 90.84.230 SS
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather on the top panel: LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the back panel to the center of the flange is 170mm) easily removable exhaust canopies 3 levels of exhaust (lower, side and front) counterweights are placed in the front pillars-pylons and are easily serviced by the rear and upper panels – polypropylene The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel is a metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Field strength meter small-sized microprocessor IPM-101M
Field strength meter small-sized microprocessor IPM-101M
Purpose: The device is designed to monitor compliance with the maximum permissible levels of high-frequency radiation (alternating electric field strength, alternating magnetic field strength and electromagnetic field energy flux density) at the workplaces of personnel servicing electrical and radio engineering installations and systems emitting an electromagnetic field, in accordance with GOST 12.1.006, GN 2.1.8./2.2.4.019 and San-PiN 2.2.4/2.1.8.055.
Doza
Zelenograd
Produced in: Moscow
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 150.74.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 150.74.230 KG
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the top panel: 4 anti-explosion valves LED dust- and moisture-proof lamp (2x10W IP65) is separated from the workspace by tempered glass thickness of 4mm flange d=250mm (distance from rear panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A easily removable exhaust visors 3 levels of exhaust on the rear panel: technological hole d = 60mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather front pillars - aluminum profile painted with powder paint (RAL 7035/RAL 5023) adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Generator of test pulses G9-1A
Generator of test pulses G9-1A
The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
Produced in: Moscow
Installation radiometric UDGB-01
Installation radiometric UDGB-01
The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
Doza
Zelenograd
Produced in: Moscow
Fume Cupboard SHVS-T
Fume Cupboard SHVS-T
Overall dimensions with raised protective screen 1000x855x2250 mm Overall dimensions with lowered protective screen 1000x855x2028 mm The diameter of the exhaust pipe is 150 mm Weight 145 kg Power supply 380/220 V, 50 Hz, 16 A
Produced in: Tomsk
Areometer ADB-1M
Areometer ADB-1M
Device parameters: density measurement range, g/cm3 — with calibrated load — ( 0.8 to 1.7 ) — without calibrated load — ( 1.7 to 2.6 ) the price of dividing the hydrometer scale (main and correction), g/cm3— ( 0.01 ) working medium — water density from 0.96 to 1.039 g/cm3 at temperature, 0C — (from 5 to 50 ) the capacity of the hydrometer cup, cm3 — (78.5 +0.3) the limit of permissible absolute error at the temperature of the test solution, the environment and water 20 +2, g /cm3— (0.01) the mass of the calibrated load, g — (81.58 +0.1 ) overall dimensions of the hydrometer, mm — ( 66x454 ) weight of hydrometer with case, kg — ( 1,450 )
Produced in: Krasnodar
High-temperature smart surface  probe  L=300 mm SZPVV.300
High-temperature smart surface probe L=300 mm SZPVV.300
from 12 960 ₽
The high-temperature smart surface probe L=300 mm SZPVV.300 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVV.300 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVV smart probe.300 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
A set of measures of electrical resistance H2-2
A set of measures of electrical resistance H2-2
Designed for storing and transmitting the size of a resistance unit, as well as for checking and calibration of working resistance measures and complex resistance meters with a four-pair or five-clamp connection scheme in the frequency range from DC to 10 MHz. Description: Each of the resistance measures H2-2 is a precision resistor, in series and in parallel to which fitting resistors are connected, placed in an aluminum housing. The measures have a four-pole connection scheme. Four BNC type connectors (plugs) are located on the wall of the housing. The distance between the connectors is 22 mm. In measures of 100 kOhm and 1 mOhm, it is possible to adjust the value of the time constant of the measure using a tuning capacitor.
MNIPI
Minsk
Produced in: Belarus, Minsk
AP1M electronic anemometer with 2 sensors
AP1M electronic anemometer with 2 sensors
from 70 444 ₽
Range: 0.3 ... 20 m/s Accuracy Characteristics: (0.1+0.05V) m/s Application conditions: For primary measuring transducers: in the range of 1-20 m/s from minus 30C to plus 50C.
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
X-ray Radiation Dosimeters Clinical DRC
X-ray Radiation Dosimeters Clinical DRC
X–ray radiation dosimeters clinical DRC, depending on the modification, are designed for: measuring the product of the kerma (absorbed dose) in the air by the cross-sectional area of the X-ray beam (hereinafter referred to as the product of the kerma in the air by the area) when using the DRC-1, DRC-1E, DRC-1M Outline, DRC-1M dosimeters with the DRC measuring console-1M-E03, DRC-1M-E04, DRC-1M-E05, DRC-1M-E06; measurements of the product of the kerma power (absorbed dose) in the air per area (hereinafter referred to as the product of the kerma power in the air per area) using the DRK–1E and DRK-1M dosimeters equipped with the DRK-1M-E06 measuring console; measurements of the product of the kerma (absorbed dose) in the air along the length (hereinafter referred to as the product of the kerma in the air along the length) using DRK-1M-CT dosimeters; measurements of kerma (absorbed dose) in the air; measurements of the kerma power (absorbed dose) in the air when using DRK-1M dosimeters.
Doza
Zelenograd
Produced in: Moscow