Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
UKK-6 CRYOCONCENTRATION UNIT
UKK-6 CRYOCONCENTRATION UNIT
The UKK-6 cryoconcentration unit (hereinafter referred to as UKK-6) is an integral part of an automated chromatographic complex based on the Kristallux-4000M gas chromatograph and is designed to control the quality of 6.0 grade helium and 6.0 grade hydrogen for the presence of micro-impurities of Ne, CH4, O2+Ar, N2, CO, CO2 and H2.AUKK-6 concentrates gaseous impurities (Ne, H2, O2+Ar, CH4, CO and CO2) in helium and hydrogen in sorption columns at liquid nitrogen temperature, followed by focusing and thermal desorption of accumulated impurities and introducing them into a gas chromatograph to determine their qualitative and quantitative composition. technical specifications The analyzed gas is Helium, hydrogen Temperature of sorption columns during adsorption, 0C -196 Maximum temperature of thermal desorption, 0C 400 The pressure of the analyzed gas, not more than 0.4 MPa Inlet gas pressure, not more than 1.0 MPa Total analysis time, no more than 17 minutes Volume of a vessel with liquid nitrogen, l 6 Automatic replenishment (topping up) of liquid nitrogen before each concentration cycle - Supply voltage 230-240V, 50-60Hz Power consumption, no more than W0C 2000 Overall dimensions (WxDxH), mm 30 Weight, not more than 0.02-1.7 kg
Produced in: Yoshkar-Ola, Mari El
Trace Searcher Success AG-309.20N
Trace Searcher Success AG-309.20N
from 161 400 ₽
A trace searching kit for searching underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). The kit includes a receiver in the form of a monoblock with a large LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line, as well as a compact autonomous generator with an output power of up to 20 watts and a range of up to 3 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
Laboratory electric furnace CHO-10
Laboratory electric furnace CHO-10
from 153 403 ₽
Designation SNO-10 Volume, l 10 The material of the working chamber is ceramic Heating 4 sides Power consumption, W, max 4500 Minimum operating temperature, 0C 100
Produced in: Tula
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
Detection of SCR in all possible range of its characteristics High reliability Self-monitoring of components Backup power supply Recording and storage of measurement results in the non-volatile memory of the device The possibility of integration with external security systems DRG-AT2331 together with SRK-AT2327, personal computer and software "SARK.NET " allows you to form an alarm system for detecting the occurrence of a self-sustaining chain reaction (SAS SCR).
Produced in: Belarus, Minsk
Mobile electrotechnical laboratory ETL TECHNOAS 2 based on Gazelle Next NN
Mobile electrotechnical laboratory ETL TECHNOAS 2 based on Gazelle Next NN
The purposes of the ETL TECHNOAS 2 laboratory based on Gazelle Next NN are: • – Testing and searching for damage to cable lines up to 10 kV + SNF (cross–linked polyethylene); • - Posititioning of the location and depth of underground utilities (power and signal cables); • – Identifying the nature of the damage and the distance to the damage site without burning the cable insulation; • – Testing of the cable with alternating high voltage; • – Tests of power cables and cable sheaths with cross-linked polyethylene insulation; • – Measurement of insulation resistance of electrical circuits. ETL TECHNOAS 2 laboratory based on Gazelle Next NN consists of following parts standartly: 1. – Color design; 1. – Laboratory compartment; 1. – Partition between compartments; 1. – Windows: rear side-blind, there is a plastic window with a cable coupling in the rear door; 1. – A 10x10 hatch in the lower right corner for cable output; 1. – Finishing of sidewalls and ceiling; 1. – Floor covering: autolinoleum; 1. – On-duty lighting: standard; 1. – Working lighting: fluorescent lamps; 1. – Furniture: main stand, soft seat. Electrical safety system of ETL TECHNOAS 2 laboratory based on Gazelle Next NN incledes following parts: • – MKZ safety control module; • – Locking switches on the doors of the in/out compartment; • – Audible alarm; • – Light alarm; • – Emergency shutdown button; • – Input release with visible contact break. Additional equipment of ETL TECHNOAS 2 laboratory based on Gazelle Next NN includes: • – 12/220 V voltage converter; • – Diesel/gasoline generator (for field operation); • – Laboratory power management system; • – Additional heater; • – Air conditioning.
Produced in: Kolomna, Moscow region
P-400 Flow Vacuum Trap
P-400 Flow Vacuum Trap
The LP-400(R) flow-through water trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the cooled elements of the freezing device.
Produced in: Kazan
Spectrometer SPECTROSCAN MAX-GVM
Spectrometer SPECTROSCAN MAX-GVM
The spectrometer is designed to determine the contents of elements in the range from Na to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. The principle of operation of the X-ray spectrometer is based on irradiation of the sample with primary radiation from an X-ray tube, measurement of the intensity of secondary fluorescent radiation from the sample at wavelengths corresponding to the elements to be determined, and subsequent calculation of the mass fraction of these elements according to a pre-constructed calibration characteristic, which is the dependence of the content of the element to be determined on the measured intensity. Secondary fluorescent radiation is decomposed into a spectrum using a crystal analyzer. Due to this, the X-ray fluorescence spectrometer has a high resolution, and therefore the ability to accurately analyze complex multicomponent substances.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
LB23-Sh Laboratory bath
LB23-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Two workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 7 liters and a depth of 160 mm. The volume of the bath is 7 liters Overall dimensions 515x360x710 mm The open part of the bath is 295x145 mm Bath depth 160 mm Weight 7.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Muffle furnace LF-9/11-V2
Muffle furnace LF-9/11-V2
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x1015x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg