The consistometer can be used in laboratories of grouting offices, drilling departments and oil-producing associations, as well as in laboratories of research organizations engaged in the development of formulations and research of grouting cements, mixtures and solutions for cementing wells.
The consistometer can be transported to the place of testing cement mortars in compliance with the rules of transportation specified in the passport of the device, while no additional calibration is required.
The consistometer works in conjunction with a personal computer, as well as in offline mode under the control of a microprocessor system. The pressure is set by a manual high-pressure pump by the operator.
In the dialog mode, the operator sets the parameters necessary for testing grouting solutions. The test results can be transmitted via the USB interface to a personal computer for printing, archiving or processing by user programs.
Technical specifications
The range of determination of consistency is from 0 to 100 units of consistency (1e.k. = 1 Bc, Bc is a unit of consistency of Burden).
The limit of the permissible reduced error in determining the consistency is ± 5% of the measurement range (100 E.K. = 100 Bc).
The rotational speed of the measuring frame in cement mortar is (150 ±1) rpm.
The heating range of the tested solutions is from the current temperature to 200 ° C.
The limit of the permissible reduced error in determining the temperature is ± 1%.
The range of the tested pressure is from the current, atmospheric,
to 100 MPa.
The limit of the permissible reduced error in determining the pressure in the autoclave is ± 2.5%.
Operating conditions:
ambient temperature – from +10 to +35 ° C;
relative humidity up to 65% at 20 ° C and up to 80% at 27 °
C.
The electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm.
The electrical insulation between the electrical circuits and the housing under the conditions of clause 2.7. must withstand an alternating current voltage of 1.5 kV of a sinusoidal shape with a frequency of 50 Hz.
Power supply of the installation:
voltage: ≈ 220 V ±10%;
the frequency of the supply network is 50 Hz;
power consumption, no more than - 3 kW.
Overall dimensions, not more than, mm: 750x400x1000;
The average service life is at least 10 years.
The mass of the consistometer is no more than 145 kg.