EVRAZCOMB – 2 in 1
EVRAZCOMB – 2 in 1
Purpose: Temperature measurement and sampling of molten steel. Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1400 to 1800 °C - metal temperature Accuracy: 0 + 3°C at 1554°C The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Universal calibrator H4-24
Universal calibrator H4-24
The main field of application of the calibrator is the verification of measuring instruments. The calibrator is capable of operating both independently and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 and ETHERNET. Technical specifications Ranges of reproduction of electrical quantities: - constant electrical voltage from 0 to 1000 V - alternating electric voltage in the frequency range from 10 Hz to 70 kHz from 0.9 mV to 1050 V - alternating electric voltage in the frequency range up to 100 kHz up to 750 V - alternating electrical voltage in the frequency range up to 1 MHz to 110 V - the power of direct electric current from 0 to 2 A - the power of alternating electric current in the frequency range from 10 Hz to 10 kHz from 0.9 µA to 2 A - electrical resistance of 1, 10, 100 ohms, 1,10,100 kOhm, 1,10,100 mOhm Errors in the reproduction of electrical quantities: - constant electrical voltage ± (0.0012 – 0.003)% of U + (0.0003 – 0.015)% of Up - alternating electric voltage in the frequency range from 10 Hz to 1 MHz ± (0.007 – 0.3)% of U + (0.001 – 0.25)% of Up - DC current ± (0.004 – 0.007)% of I + (0.001 – 0.01)% of Ip - AC electric current in the frequency range from 10 Hz to 10 kHz ± (0.015 – 0.1)% of I + (0.002 – 0.1)% of Ip - electrical resistance ± (0.002 – 0.005)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 480x200x550 Weight, not more than 35 kg
Produced in: Moscow
Laboratory electronic thermometer LTA-E
Laboratory electronic thermometer LTA-E
It can be used as an accurate universal thermometer for contact temperature measurement of non-aggressive liquid, bulk and gaseous media. It can be connected to a computer for calibration and transmission of measurement results. • Range of temperature measurements -50...+200 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Microphone condenser capsule M-101
Microphone condenser capsule M-101
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
EVRAZCOMB – TSC
EVRAZCOMB – TSC
Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
High-frequency signal generator G4-232
High-frequency signal generator G4-232
A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
OCTAVE-111 Noise meter, spectrum analyzer
OCTAVE-111 Noise meter, spectrum analyzer
Functionality ■ Sound level measurement: Class 1 according to GOST 17187-2010, IEC 61672-1 ■ Measures sound pressure levels in octave and third octave frequency bands ■ Has a metal body, resistant to external influences ■ Automatic recording of measurement results in memory ■ Non-volatile memory ■ Telemetry channel, remote control and operation of the device Features ■ Easy setup: one measurement mode, all values are measured simultaneously ■ Easy to manage: all results are grouped in two windows ■ Measurement of sound levels below 20 dBA ■ Affordable solution Application areas ■ Noise control in residential and public buildings ■ Noise control on the territory of enterprises and residential buildings ■ Production control ■ Vehicle inspection Complies with standards: - as a noise meter: GOST 53188.1-2019 (17187-2010, IEC 61672-1), Class 1 - as a spectrum analyzer: GOST R 8.714-2010, IEC 61260 (Class 1) Noise meter mode - Measuring range of sound levels, dBA: from 19 to 150* - Frequency characteristics: A, C, Z, AU, FI, G - Time characteristics: S, F, I, Peak, Leq * When equipped with 50 mV/Pa microphones and 12 mV/Pa Spectrum Analyzer mode with constant relative bandwidth - Frequency range of digital octave filters, Hz: 31.5 - 16000 - Frequency range of digital third-octave filters, Hz: 25 - 20000
Produced in: Moscow
The self-recording meter IS-203.1.0
The self-recording meter IS-203.1.0
from 8 940 ₽
The measuring recorder IS-203.1.0 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.0 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.0 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region
IRI-04M Individual Logger-indicator
IRI-04M Individual Logger-indicator
from 87 000 ₽
It is intended for registration and indication of electromagnetic factors and conditions that create a potential spark threat caused by the "human factor", natural phenomena and man-made failures of equipment and power grids, in order to prevent technical operations with gas and oil products.
Produced in: Moscow