Metrology

525 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Areas of use
    Loading...
  • 194
    Item names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 55
    Additional
    Loading...
View:
525 products
OCTAVE-111 Noise meter, spectrum analyzer
OCTAVE-111 Noise meter, spectrum analyzer
Functionality ■ Sound level measurement: Class 1 according to GOST 17187-2010, IEC 61672-1 ■ Measures sound pressure levels in octave and third octave frequency bands ■ Has a metal body, resistant to external influences ■ Automatic recording of measurement results in memory ■ Non-volatile memory ■ Telemetry channel, remote control and operation of the device Features ■ Easy setup: one measurement mode, all values are measured simultaneously ■ Easy to manage: all results are grouped in two windows ■ Measurement of sound levels below 20 dBA ■ Affordable solution Application areas ■ Noise control in residential and public buildings ■ Noise control on the territory of enterprises and residential buildings ■ Production control ■ Vehicle inspection Complies with standards: - as a noise meter: GOST 53188.1-2019 (17187-2010, IEC 61672-1), Class 1 - as a spectrum analyzer: GOST R 8.714-2010, IEC 61260 (Class 1) Noise meter mode - Measuring range of sound levels, dBA: from 19 to 150* - Frequency characteristics: A, C, Z, AU, FI, G - Time characteristics: S, F, I, Peak, Leq * When equipped with 50 mV/Pa microphones and 12 mV/Pa Spectrum Analyzer mode with constant relative bandwidth - Frequency range of digital octave filters, Hz: 31.5 - 16000 - Frequency range of digital third-octave filters, Hz: 25 - 20000
Produced in: Moscow
The self-recording meter IS-203.1.0
The self-recording meter IS-203.1.0
from 8 940 ₽
The measuring recorder IS-203.1.0 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.0 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.0 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region
IRI-04M Individual Logger-indicator
IRI-04M Individual Logger-indicator
from 87 000 ₽
It is intended for registration and indication of electromagnetic factors and conditions that create a potential spark threat caused by the "human factor", natural phenomena and man-made failures of equipment and power grids, in order to prevent technical operations with gas and oil products.
Produced in: Moscow
AF18-20dB
AF18-20dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, 20 dB Attenuation error, dB ± 1.0 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
VE-26NP Eddy current structuroscope
VE-26NP Eddy current structuroscope
from 195 000 ₽
Distinctive features: The built-in thermometer allows you to take into account the influence of ambient temperature and improve the measurement accuracy. The built-in memory stores 4096 electrical conductivity measurement results for subsequent transfer to a PC. Specifications: Measuring range of the absolute value of specific electrical conductivity, MSm/m from 5 to 60
Measuring range of increments of electrical conductivity, MS/m from -9.99 to +9.99 Limit of permissible basic relative measurement error, % no more than 2 Permissible gap between the transducer and the surface of the controlled product, mm, no more than 0.25 Digital display of measurement results Power supply from RRZ type battery, V 9 Power consumption, mW, no more than 40 Operating temperature range, °C 5...40 Dimensions, mm 57*84*30 Weight, g 270±20
Produced in: Moscow
Wall-mounted Smart Relative Humidity and Temperature Probe
Wall-mounted Smart Relative Humidity and Temperature Probe
from 13 920 ₽
The smart relative humidity and temperature probe wall-mounted SZVLN is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitorbased on the Android program. Operating conditions of the SZVLN smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SZVLN Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Immitance meter E7-21
Immitance meter E7-21
Technical specifications: Capacitance (10-13-0.02) F, inductance (10-8–16x103) Gn Resistance (10-3–2x107) ohms Conductivity (10-9-10) Cm Q factor, loss factor 10-3-103 The error is ±0.15% Offset voltage 2±0.2 V Measuring signal levels (0.1±0.02) V and (1±0.2) V Range selection: automatic, manual RS-232C interface Dimensions, weight: 90x265x317 mm, 2 kg Power supply: ~220V, 10 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
 Electronic Stopwatch-Meter IVPR-53SCH
Electronic Stopwatch-Meter IVPR-53SCH
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-53SCH is a panel device for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
The BREEZE-3 aspirator
The BREEZE-3 aspirator
from 62 000 ₽
The aspirator refers to universal, electric, single-channel, portable devices with set volume flow values, with direct measurement of the sampled volume of air samples in accordance with GOST R 51945-2002.
Produced in: Moscow
VLE-1023CI Comparator Scales
VLE-1023CI Comparator Scales
1 supp.
Technical characteristics: NIP, G1020 Discreteness, g0,001 Self-calibration The size of the scale bowl / platform, mm108x105 The smallest weighing limit, g0,1 The price of the verification scale division, mg10 The limits of permissible error during initial verification, mgot 0.1g to 500 g incl. ±5; sv. 500g to 1020g incl. ±10 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 4 in the entire range The weight adjustment is built-in The setting time, s, no more than ~ 1.5 7 years warranty
NPK LUCH
Balashikha
Produced in: Balashikha, Moscow region
Smart probe for connecting an external thermoelectric converter of the CVT
Smart probe for connecting an external thermoelectric converter of the CVT
from 10 626 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. The smart probe for connecting an external thermoelectric converter is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the smart probe of the SSVT Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe of the SSVT Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor.The Android program is installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
Control of individual radiation doses from X-ray and gamma radiation. Together with a reader connected to a PC and specialized application software, they form an effective system for automated control of dose loads on personnel. Silicon Planar Detector Lack of own background Simultaneous measurement of dose loads on internal organs Hp(10) and skin Hp (0.07)
Produced in: Belarus, Minsk