Search

4008 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 25
    Foreign brand
    Loading...
  • 46
    By name of foreign product
    Loading...
  • 525
    Names
    Loading...
  • 4008
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 131
    Manufacturer
    Loading...
View:
4008 products
Laboratory container for sampling according to TU 9464-014-29508133-2013, 60 ml with screw. roof., n/a., n/a, box.500 pcs
Laboratory container for sampling according to TU 9464-014-29508133-2013, 60 ml with screw. roof., n/a., n/a, box.500 pcs
from 1 800 ₽
Provides complete tightness during transportation of biological material. The container material is polypropylene, the lid is polyethylene. It has a graduated and frosted window for recording. Non-sterile.
MiniMed
Suponevo
Produced in: Bryansk region
General purpose exhaust cabinet LAB-PRO SHV 120.74.230 TR
General purpose exhaust cabinet LAB-PRO SHV 120.74.230 TR
BASIC EQUIPMENT Working box guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel is a metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Crystallization bowl diam.100 mm, pack of 6 pcs
Crystallization bowl diam.100 mm, pack of 6 pcs
from 401 ₽
Designed for evaporation and recrystallization of chemicals. Made of TS glass according to GOST 21400-75.TU 4320-012-29508133-2009.
MiniMed
Suponevo
Produced in: Bryansk region
Primelab evaporator with GL14 thread
Primelab evaporator with GL14 thread
Threaded evaporator GL14 PrimeLab is a convenient laboratory device designed for working with liquid evaporations. A GL14 thread is provided, thanks to which the evaporator can be firmly attached to laboratory equipment or other installation elements. There are tubes on the top and sides. The threaded evaporator was manufactured by Primelab, which provides glassblowing services. We accept orders for the production of various products from borosilicate glass in a short time according to customer parameters.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Laboratory container for sampling sterile 60 ml with screw. roof., p/p, ind.pack./pack.50pcs/box. 400 pcs
Laboratory container for sampling sterile 60 ml with screw. roof., p/p, ind.pack./pack.50pcs/box. 400 pcs
from 285 ₽
Provides complete tightness during transportation of biological material. The material of the container is polypropylene, the lid is polyethylene. It has a graduated and frosted window for recording. Sterile.
MiniMed
Suponevo
Produced in: Bryansk region
Primelab density measurement setup
Primelab density measurement setup
from 190 000 ₽
The Primelab installation has the following equipment: Three double-walled glass hydrometer cylinders with glass or Teflon stopcocks (available in two versions); Rack with clamps for three cylinders; Glass manifolds for three cylinders – 2 pcs.; PTFE cover for the cylinder – 3 pcs; Silicone tubes 1 meter – 2 pcs. At the bottom of each cylinder there is a tap that allows you to rinse the container from the previous sample without disassembling the installation for a quick transition to the analysis of the next product. It is possible to supply additional cylinders and a circulation thermostat. A liquid thermostat will be selected upon request. The installation equally accurately determines the density of light and dark products, including gasoline, crude oil, diesel fuel, etc. Specifications: Number of cylinders assembled – 3 The height and volume of each cylinder is 350 mm x 750 ml Measurement temperature – from -5 to 100°С Temperature maintenance accuracy - 0.1°C Tripod base size – 300 mm x 300 mm Tripod height – 700 mm The weight of the installation without glass cylinders is 10 kg. Installation benefits The Primelab petroleum product density measurement unit has a number of advantages. Among the main and significant ones are the following: Removable stainless steel tray; All glass elements are made of Simax borosilicate glass; Wide operating temperature range; The hydrometer is visible along the entire length of the glass cylinders; Removable stainless steel tray; PTFE covers; The small size of the installation allows it to be placed in almost any area. Characteristics Country Russia Volume, ml: 750 (each cylinder) Height, mm: 350 (each cylinder) Compliance: GOST 3900-85, ASTM D1298 Accuracy: up to 0.1°C Version: floor, tabletop Temperature measurement range, °C: -5 to +100 Dimensions: base - 300x300 mm, height - 700 mm Device weight, kg: 10 (without cylinders) Unique opportunity: custom manufacturing of a Primelab installation for determining the density of petroleum products to meet specific customer requirements.
Primelab
Mytishchi
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
Produced in: Moscow
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
3VVN1-6M(N) Water ring vacuum pump
3VVN1-6M(N) Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-6M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-6M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-6M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
NV-800 NS Outdoor wall rack (800×350×350)
NV-800 NS Outdoor wall rack (800×350×350)
from 2 978 ₽
The NV-800 NS hinged rack is designed for storing devices and materials in the laboratory. Included in the set: shelf-insert, without doors; wall rack, without doors; metal hanging brackets for attaching it to the wall.
NV LAB
Moscow
Produced in: Moscow, Moscow region