Magnetic stirrer with heating for 2 liters PL-RH-atom
Magnetic stirrer with heating for 2 liters PL-RH-atom
from 19 000 ₽
Characteristics Maximum heating temperature of the working surface, °C 150 A country Russia Overall dimensions, L×W×H, mm 165.5x148x64 Protection class acc. to DIN EN60529 IP21 Color orange Mixing 150-2000 rpm Number of mixing places 1 Maximum volume of mixed liquid, l 2 Working surface of the plate (platform) fireproof glass (glass ceramics) Slab working surface size, LxW, mm 120x120 mm Accuracy of maintaining the plate temperature, % 1 Displayed temperature resolution, °C 0.1 External temperature sensor PT1000 Power consumption, W 300 Device weight, kg 0.9
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Desiccator 1-210 mm Primelab, with tap, dark glass
Desiccator 1-210 mm Primelab, with tap, dark glass
from 10 553 ₽
1 supp.
Desiccator 1-210 mm PrimeLab with tap is made of durable dark glass. Suitable for creating stable, low-humidity conditions for storing and drying light-sensitive substances. It can be connected to a vacuum pump. Desiccator 1-210 mm holds up to 4500 ml of substance of any consistency. Its diameter is 210 mm with an insert diameter of 176 mm. The container has a durable design and is quite easy to use. Features a long service life even with intensive use.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM01.02.8 Primelab
Vacuum membrane pump PL.HM01.02.8 Primelab
from 170 000 ₽
1 supp.
Vacuum membrane pump PL.HM01.02.8 Primelab is an effective laboratory device for creating a vacuum, pumping gases and vapors. It has high productivity (38 l/min) with a maximum residual pressure of 8 mbar. The PL.HM01.02.8 Primelab pump is suitable for working with chemically active and toxic substances, since the chambers are made of fluoroplastic, and all elements and parts have a fluoroplastic coating. In this case, the valves are made of FFKM. The device has a light weight of 8 kg and compact dimensions (321.5x160x200 mm), allowing it to be placed in an already equipped space. Supplied in a complete set sufficient for quick assembly and start of work.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Along AIO 29/32-19/26-65 TS Primelab
Along AIO 29/32-19/26-65 TS Primelab
from 1 523 ₽
Alonge AIO 29/32-19/26-65 TS Primelab is a strong, durable and reliable connecting component suitable for various laboratory installations and instruments. It has a side outlet and a curved shape with an inclination angle of 105°. At the end of the outlet there is an olive that provides a strong connection with the soft hose. Made from durable Simax borosilicate glass, which has proven itself in the best way during use. Has a long service life and excellent wear resistance. The total length of the device is 65 mm, of which 20 mm is on the narrow lower part with a diameter of 9 mm. The size of the coupling section is 19/26, and the core size is 29/32.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Drop eliminator Primelab
Drop eliminator Primelab
The Primelab droplet eliminator is designed to collect condensate or liquid droplets that form during various laboratory processes. Suitable for determining the moisture content in test mixtures. The device is actively used in distillation apparatuses, chemical plants and devices in which distillation is performed. It has a fairly compact size, is convenient and easy to use. The Primelab company is ready to produce droplet eliminators of various shapes, with and without ground sections. The work is carried out according to the client’s technical specifications or drawing.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Alonge type "Spider" with vacuum valves KV-19 14/23-19/26 Primelab
Alonge type "Spider" with vacuum valves KV-19 14/23-19/26 Primelab
1 supp.
The "Spider" type with vacuum valves KV-19 14/23-19/26 Primelab has a non-standard appearance. Serves as a connecting element in laboratory installations, apparatus and devices. It has a reliable design that guarantees excellent tightness and prevention of gas leakage. The product is made in accordance with GOST from borosilicate glass, which does not enter into chemical reactions with contacted substances and is not afraid of temperature changes. The Primelab company accepts orders for the production of equipment and glassware according to the customer’s individual parameters.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Primelab filtration apparatus, 250 ml flask
Primelab filtration apparatus, 250 ml flask
from 4 795 ₽
The PrimeLab filtration apparatus with a 250 ml flask allows for fast and clean filtration, which is important for a wide variety of laboratory processes. Made from durable borosilicate glass and stainless steel, which are resistant to heavy use and have a long service life. The installation consists of several parts: • Adapter with outlet • 250 ml conical flask • Filter and clamp for it • 300 ml cylindrical funnel. All parts are hermetically connected to each other. The liquid with sediment is placed in a glass flask made of borosilicate glass. The volume of the filtrate receiver is 250 ml.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Mini press for producing thin layers of substance on steel mirror plates
Mini press for producing thin layers of substance on steel mirror plates
It is intended for sample preparation when examining samples using an IR microscope and mirror reflection prefixes. Allows you to shape a thin layer (up to several microns) to various objects: polymer fragments, microparticles of LCP, powdery substances, fibers, etc. The resulting thin layers on mirror plates made of alloy steel are investigated by the double transmission method – when the radiation that has passed through the layer of matter is reflected from the surface of the plate and passes through the substance again. The spectra recorded by this method are completely identical to the transmission spectra obtained, for example, after pressing substances with KBr. The advantages in this case are: - speed of sample preparation - there is no need to use hydraulic and manual presses and molds, grinding mortars, etc. - no need to use high-purity KBr or petroleum jelly oil - the sample is not lost and, if necessary, can be examined by other methods - when using an IR microscope, it is possible to “scan” the resulting thin layer to select the most informative area, and also, if the layer is heterogeneous in composition, to obtain the spectral characteristics of its components.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
A set-top box with a cooled MST detector
A set-top box with a cooled MST detector
To achieve the maximum sensitivity during measurements, a special prefix is used to the FT-801 Fourier spectrometer, which is an optical unit with a built-in highly sensitive MST detector cooled with liquid nitrogen. The set-top box is installed in the cuvette compartment of the spectrometer and connected to the corresponding external electrical port, the detector is turned on programmatically. In this case, the sensitivity of the method increases many times (up to 20) – depending on the type of standard uncooled detector in the spectrometer). The speed of recording spectra is also increasing. The operating time after filling the cryostat (200 ml capacity) with liquid nitrogen is at least 6 hours. Increasing the sensitivity of the spectrometer using a prefix with an MST detector may be required for many applications: in fiber spectroscopy, when recording emission spectra of low-power emitters, in trace gas analysis with high spectral resolution, when determining the presence of impurities in samples in ultra-low concentrations, when using multi-pass gas cuvettes, etc. In the picture: on the left in the cuvette compartment there is a capler with fiber from Art photonics GmbH, Berlin, Germany, on the right there is a prefix with an MST detector. Technical specifications The recommended number of scans when registering spectra is 16 Spectrum registration time at 50 scans (resolution 4 cm-1), sec 20 Cryostat capacity, 200 ml Working time after filling the cryostat, 6 hours Overall dimensions, mm 225×175×75 Weight, kg 1.45
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Diamond thermal cell NPVO with temperature controller
Diamond thermal cell NPVO with temperature controller
The sample heating system is designed to expand the capabilities of standard set-top boxes NPVO-ZDO and NPVO-A. It consists of a heated replaceable frame with a diamond prism and a temperature controller unit. For most solid samples in the heated state, it is possible to obtain a much more pronounced NPV spectrum than in the cold state. This makes it possible to increase the sensitivity of the method several times. The properties of some substances and compounds change dramatically with an increase in temperature, chemical interaction processes between components, their decomposition, oxidation in air, etc. may occur. If changes in the chemical composition of a substance occur during heating, a set of spectra corresponding to the kinetics of the process can be obtained with the help of an NPVO prefix with a diamond thermocell and a temperature controller, which is essential expands the possibilities of the method in research. Technical characteristics of the NPVO set-top box with a thermocell and a controller Transmission in the operating range of the spectrum, % of the input signal at least 10 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum dimensions of the solid sample, mm 0.5 × 0.5 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.3/1 The material of the crystal substrate is DIAMOND The diameter of the free zone of the crystal, mm not less than 2 x 3 The diameter of the focus spot, mm 1.5 Maximum temperature With 220o Adjustment accuracy, With 1o Time to reach the maximum temperature, min 10 Overall dimensions, mm 130×200×90 Weight, kg 1,2
SIMEKS
Novosibirsk
Produced in: Novosibirsk