Search

4008 products
View:
  • Selected: 0
    Foreign brand
    Loading...
  • Selected: 0
    By name of foreign product
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Russian analogue
    Loading...
  • Selected: 0
    Applying
    Loading...
All filters
  • 25
    Foreign brand
    Loading...
  • 46
    By name of foreign product
    Loading...
  • 525
    Names
    Loading...
  • 4008
    Russian analogue
    Loading...
  • 24
    Applying
    Loading...
  • 131
    Manufacturer
    Loading...
View:
4008 products
Bunsen flask 1-15000 Primelab TS
Bunsen flask 1-15000 Primelab TS
from 5 109 ₽
1 supp.
Bunsen flask 1-15000 Primelab TS is a reliable laboratory product with a wide base, narrow neck and side outlet. Suitable for various laboratory processes, but mainly used for vacuum filtration purposes. Made from heat-resistant glass. Characteristics of flask 1-15000: • Volume – 15 liters • Height – 50 cm • The diameter of the outlet is 1.5 cm.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 150.74.230 KG
Exhaust cabinet for working with LVZH LAB-PRO SHVLVZH-TB 150.74.230 KG
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel. AISI 304 steel rear, upper, side panels – metal painted with powder paint (RAL 7035) with the texture of shagreen leather 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – tempered glass in an aluminum frame on the top panel: 4 anti-explosion valves LED dust- and moisture-proof lamp (2x10W IP65) is separated from the workspace by tempered glass thickness of 4mm flange d=250mm (distance from rear panel to the center of the flange – 170mm) switching box with automatic emergency power off 16A easily removable exhaust visors 3 levels of exhaust on the rear panel: technological hole d = 60mm with a plastic plug counterweights are placed in the front pillars-pylons and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather front pillars - aluminum profile painted with powder paint (RAL 7035/RAL 5023) adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted high table LAB-PRO SPKv 90.80.90 SS
Wall-mounted high table LAB-PRO SPKv 90.80.90 SS
Combined working surface: STEEL main table top (single stainless steel module with anti-spill side) with a depth of 650 mm / auxiliary table top made of TRESPA material with a depth of 150 mm Length, mm: 900 Depth, mm: 800 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Apparatus for determining the flash point in an open crucible TVO-LAB-01
Apparatus for determining the flash point in an open crucible TVO-LAB-01
The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range, °C from +79 to +400 Heating speed, °C/min 2.0...20.0 Power consumption from AC 220 V, no more, 800 W Overall dimensions of the device, not more than, mm 400x360x470 Weight of the device, not more than, kg 14 Igniting a gas flame
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Installation for obtaining analytical quality water UPVA-25
Installation for obtaining analytical quality water UPVA-25
from 199 000 ₽
Capacity, l/h 25,0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 2.7 kW 220V (stainless steel) – 6 pcs. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, three-phase alternating voltage, 50 Hz, 380 V Power consumption, kW 16.3 Overall dimensions (L×W×C), mm 660x550x760 Weight, kg 50,0
Livam
Belgorod
Produced in: Belgorod
RNA Vaccine production System
RNA Vaccine production System
1 supp.
It allows the generation of lipid particles for their subsequent use in the creation of RNA vaccines. The Russian equivalent of Nanoassembler systems.
Abisens
Sirius
Produced in: Krasnodar region
Exhaust cabinet LAB-900 SHV-N
Exhaust cabinet LAB-900 SHV-N
Working surface: Porcelain stoneware (ceramic tile 300*300mm) Length, mm: 938 Depth, mm: 726 Height, mm: 2100 equipment Working box front anti–spill side - TRESPA TopLab sink-drain (polypropylene, internal size 250*100*150mm), pipe for water the package includes a corrugated siphon 2 flexible eyeliners with a length of 1200mm housing – melamine with a thickness of 16mm lifting screen with the possibility of fixing at any height – tempered glass with a thickness of 5mm, lifting 0-700mm, increase the height of the cabinet at full lifting by 450mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
RF power amplifiers
RF power amplifiers
Basic electrical characteristics 1. Operating frequency, MHz 63.85 MHz ± 0.2 2. Rated output power, at least, kW 1 1 3. Deviation of the amplitude characteristic from the linear one, no more than, dB 2 4. Relative level of harmonic components of the output signal, no more than, dB minus 20 1, 2 5. Nominal level of the input RF signal, dBm 3 6. Input and output impedance, ohms 50 7. VSWR RF input, no more than 2 8. Permissible VSWR RF load, no more than 3 9. Pulse mode of operation 10. Duration of the radio pulse, no more than, ms 100 11. Effective borehole, at least 2 12. Rise/fall time of the RI amplitude, no more than, ns 500 1, 4 13. Noise, no more than, dB/Hz minus 154 1, 5
Produced in: voronezh
SHGS-1-SK SINGLE-SECTION LOCKER WITH BENCH
SHGS-1-SK SINGLE-SECTION LOCKER WITH BENCH
from 39 350 ₽
The locker is designed for storing clothes in the changing rooms of industrial enterprises, medical institutions, educational institutions and other facilities. The design is based on a painted aluminum profile. Doors and other locker elements are made of moisture-resistant HPL-plastic. The materials used ensure the strength and durability of the product, are not afraid of moisture, and are suitable for sanitization with disinfectants. Width - 400
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
Generator of test pulses G9-1A
Generator of test pulses G9-1A
The generator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as RS-232 and ITHERNET. Technical specifications The range of setting the pulse duration at the outputs: - τ1 from 100 ns to 10 s - t2 from 101 ns to 10.1 s - t3 from 10 ns to 3600 s The range of setting the time interval between the pulse fronts at outputs t1 and t2 (∆tx) is from 0 to 3600 s The main error in setting the pulse duration at outputs t1 and t2 ± (δ0 • t1,2 + 1•10-8 c) The basic error of setting the pulse duration at the output is τ3 ± (δ0 •τ3 + 2 •10-9 s) The main error in setting the duration of the time interval (∆tx): ∆tx from 0 to 1000 s ± (δ0 •∆tx + 2•10-10 s) ∆tx from 1000 to 3600 s ± (δ0 •∆tx + 2•10-9 s) Pulse amplitude at outputs τ1 , τ2 and τ3 at a load of 50 ohms, not less than 1.2 V The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator (δ0 ), no more than ± 2x10-7 in 24 months The pulse repetition frequency setting range at outputs τ4 and τ5 is from 0.1 Hz to 300 MHz The main error in setting the pulse repetition frequency at outputs τ4 and τ5 ± δ0 •F = τ4.5 Pulse amplitude setting range at outputs τ4 and τ5 from 0.05 to 1 V The main error in setting the pulse amplitude at outputs τ4 and τ5 ± 20% Fixed values of pulse durations at the output of τ6 1 and 5 microseconds The basic error of setting the pulse duration at the output is τ6 ± (0.2•τ6 + 3 •10-7 s) The nominal value of the pulse repetition frequency at the output is τ6 100 kHz The main error in setting the pulse repetition frequency at the output is τ6 ± δ0 •F = τ6 Fixed values of the pulse amplitude at the output of τ6 minus 10 V; minus 2.5 V; 2.5 V; 10 V The main error in setting the pulse amplitude at the output is τ6 ± 20% Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 442x160x452 Weight, not more than 10 kg
Produced in: Moscow
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*100 mm, blue, PET,pack.100 pcs,
Vacuum tube MiniMed with sodium citrate 3.8%, 4.5 ml,13*100 mm, blue, PET,pack.100 pcs,
from 693 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Research material............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region