Search

162 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 12
    Applying
  • Names
  • 9
    Manufacturer
  • 11
    Made in
  • 5
    Additional
View:
162 products
Liquid thermostat VT-R-01
Liquid thermostat VT-R-01
The operating temperature range is +20...+100 °C. Two workplaces for placing prepared Raid bombs with pressure gauges. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. The volume of the bath is 30 liters Overall dimensions 335x280x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm Weight 25 kg Power consumption 2.2 kW
Produced in: Tomsk
Circulation thermostat LT-111a
Circulation thermostat LT-111a
The LOIP LT-111a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Water+5 ... +100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, bar 0.17 Bath volume, l 11 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 160x240/200 Overall dimensions, mm 268x335x420 Weight, kg 10
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-111b
Circulation thermostat LT-111b
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 11 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 160x240/200 Overall dimensions, mm 268x335x420 Weight, kg 10
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-117P
Circulation thermostat LT-117P
LT-100 P thermostats are designed to maintain the set temperature of objects in the bath, as well as in closed-type external systems. The device consists of an immersion thermostat-circulator LT-100, mounted on a panel, and a transparent polycarbonate working bath, which allows monitoring the test. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 17 The working fluid is water, water-glycerin mixture. The open part of the bath / depth, mm 360x295/150 Overall dimensions, mm 530x330x320 Weight, kg 5,2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Dry-air low-temperature thermostat BIOTEST
Dry-air low-temperature thermostat BIOTEST
Operating temperature range +10...+30 °C. Instability of maintaining the set temperature ± 0.5 ° C. Overall dimensions 480x620x1070 mm Weight 33 kg Power consumption 200 W
Produced in: Tomsk
VT3 Liquid thermostat
VT3 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 3 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 3 l Overall dimensions 170x350x430 mm The open part of the bath is 75x35 mm Bath depth 150 mm Weight 11 kg Power consumption 2.2 kW
Produced in: Tomsk
CRYO-VT-12-1 Low-temperature liquid thermostat
CRYO-VT-12-1 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 360 W at +20 °C. Internal bath with a volume of 6 liters and a depth of 140 mm. The operating temperature range is -30...+200 °C. Overall dimensions 280x460x620 mm The open part of the bath is 110x80 mm Bath depth 140 mm Weight 39 kg Power consumption 3.0 kW.
Produced in: Tomsk
Circulation thermostat LT-324a
Circulation thermostat LT-324a
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 24 Working fluid water, water-glycerin mixtures, silicone oil Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 532x335x400 Weight, kg 15,5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Liquid thermostat ZM1004
Liquid thermostat ZM1004
Technical specifications the maximum temperature value in the thermostat is 95 °C. the range of water heating is from the current temperature to 95 ° C. The accuracy of automatic temperature maintenance is 0.5 °C. power supply parameters at which technical characteristics are normalized: type of current – alternating single-phase; voltage , V — 220±22; AC frequency , Hz — 50 ±1; the power consumption when entering the mode should be no more than, kVA — 4; the power consumption while maintaining the temperature should be no more than, kVA - 2. Operating conditions: ambient temperature – from plus 10 to plus 35 ° C.; relative humidity, from 65 to 80%. the electrical insulation resistance between the electrical circuits and the housing at ambient temperature (20 ± 5) ° C and relative humidity (80 ± 3)% is not less than 20 mOhm. electrical insulation between the electrical circuits and the housing under the conditions of clause 2.8. must withstand an AC voltage of 1.5 kV sinusoidal frequency of 50 Hz. overall dimensions not more than, mm: 520x420x480. tank volume – 40 liters. the average service life is at least 10 years. the weight of the thermostat is not more than 26 kg.
Produced in: Krasnodar
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
The Europolitest company continues to release its "bestseller" cultivator KVM-05. This cultivator was developed and produced jointly with the Candidate of Biological Sciences prof. Grigoriev and LLC "Omikron", LLC "SFU-System" Krasnoyarsk. Since 2021, due to the reorganization of the production chain, the production of cultivators of the KVM series has been established by Europolitest LLC in the mode of a full production cycle. The thermophilic strain of chlorella algae has been widely used in ecocontrol laboratories, biotests with this test object are by far the most automated biotests that allow reducing time at all stages of work (building up the uterine culture, sample exposure in the biotest, registration of the test function). Cultivator KVM-05 is a long-lived among cultivators of this purpose and a standard of reliability, reproducibility and durability. Used in techniques: - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles by changing the optical density of the Chlorella algae test culture (Chlorella vulgaris Beijer). FR.1.39.2010.09103; MVI 1/25-2010. - Methodology for determining the toxicity of samples of surface fresh, groundwater, drinking water, wastewater, water extracts from soil, sewage sludge and waste by changing the optical density of the chlorella algae culture (Chlorella vulgaris Beijer). MON F T 14.1:2:3:4.10-04 / 16.1:2.3:3.7-04 FR.1.31.2009.06642. - Methodology for determining the toxicity of drinking, natural and wastewater, water extracts from soils, sewage sludge and waste by changing the relative index of delayed fluorescence (OPF) cultures of chlorella algae (Chlorella vulgaris Beijer) HDPE F 14.1:2:4.16-09 / 16.1:2.3.3.14-09.
Evropolitest
Ivanteevka
Produced in: Moscow region
VT10 Liquid thermostat
VT10 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 10 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. The volume of the bath is 10 liters Overall dimensions 400x275x480 mm The open part of the bath is 120x200 mm Bath depth 200 mm Weight 14 kg Power consumption 2.2 kW
Produced in: Tomsk