Liquid low-temperature thermostat CRYO-VIS-T-07
Liquid low-temperature thermostat CRYO-VIS-T-07
Operating temperature range +10...+60 °C Five places for glass viscometers. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 20 l Overall dimensions 620x400x970 mm The open part of the bath is 240x170 mm Bath depth 300 mm The size of the viewing window is 205x260 mm Weight 60 kg Power consumption 3.5 kW
Produced in: Tomsk
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
from 150 000 ₽
1 supp.
The Europolitest company continues to release its "bestseller" cultivator KVM-05. This cultivator was developed and produced jointly with the Candidate of Biological Sciences prof. Grigoriev and LLC "Omikron", LLC "SFU-System" Krasnoyarsk. Since 2021, due to the reorganization of the production chain, the production of cultivators of the KVM series has been established by Europolitest LLC in the mode of a full production cycle. The thermophilic strain of chlorella algae has been widely used in ecocontrol laboratories, biotests with this test object are by far the most automated biotests that allow reducing time at all stages of work (building up the uterine culture, sample exposure in the biotest, registration of the test function). Cultivator KVM-05 is a long-lived among cultivators of this purpose and a standard of reliability, reproducibility and durability. Used in techniques: - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles by changing the optical density of the Chlorella algae test culture (Chlorella vulgaris Beijer). FR.1.39.2010.09103; MVI 1/25-2010. - Methodology for determining the toxicity of samples of surface fresh, groundwater, drinking water, wastewater, water extracts from soil, sewage sludge and waste by changing the optical density of the chlorella algae culture (Chlorella vulgaris Beijer). MON F T 14.1:2:3:4.10-04 / 16.1:2.3:3.7-04 FR.1.31.2009.06642. - Methodology for determining the toxicity of drinking, natural and wastewater, water extracts from soils, sewage sludge and waste by changing the relative index of delayed fluorescence (OPF) cultures of chlorella algae (Chlorella vulgaris Beijer) HDPE F 14.1:2:4.16-09 / 16.1:2.3.3.14-09.
Evropolitest
Ivanteevka
Produced in: Moscow region
Liquid thermostat THERMOTEST-05
Liquid thermostat THERMOTEST-05
Operating temperature range -80...+30 °C. The stability and uniformity of the temperature in the working bath is not worse than ± 0.02 ° C without the use of a leveling unit. Bath volume 15 l Overall dimensions 800x500x1220 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 115 kg Power consumption 4.2 kW
Produced in: Tomsk
Immersion thermostat circulator LT-400
Immersion thermostat circulator LT-400
Designed to maintain the set temperature of objects in the bath, as well as for thermostating external systems: laboratory reactors, measuring cells of refractometers, viscometers, electrochemical analyzers, etc. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, (l/min) 6...12 pressure, (bar) 0,4 The working fluid is water, silicone oil. Dimensions, mm 115x240x305 Weight, kg 5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
VT15-2 Liquid thermostat
VT15-2 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external consumers of a closed or open type. Pump for closed or open type thermostating systems. All-metal stamped tub with a volume of 15 liters and a depth of 200 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 15 l Overall dimensions 420x330x480 mm The open part of the bath is 150x260 mm Bath depth 200 mm Weight 16 kg Power consumption 2.2 kW.
Produced in: Tomsk
Circulation thermostat LT-117a
Circulation thermostat LT-117a
The LOIP LT-117a modification device consists of an immersion thermostat-circulator LOIP LT-100 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +100 with tap water cooling °C Tvods+5 ...+100 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 1900 Pump: max. flow rate, l/min 7.5 pressure, 0.17 bar Bath volume, l 17 The working fluid is water, water-glycerin mixture. Open part of the bath / depth, mm 360x296/150 Overall dimensions, mm 535x335x370 Weight, kg 13
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-412a
Circulation thermostat LT-412a
The LOIP LT-412a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more, °C ±0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 12 The working fluid is water, silicone oil. The open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x350 Weight, kg 11.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-424a
Circulation thermostat LT-424a
The LOIP LT-424a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 24 The working fluid is water, silicone oil. Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 532x335x400 Weight, kg 15.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-212a
Circulation thermostat LT-212a
The LOIP LT-212a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 12 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/150 Overall dimensions, mm 355x335x370 Weight, kg 10.2
LOIP
Saint Petersburg
Produced in: Saint Petersburg
VT18 Liquid thermostat
VT18 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 18 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 18 l Overall dimensions 610x340x430 mm The open part of the bath is 360x260 mm Bath depth 150 mm Weight 16 kg Power consumption 2.2 kW.
Produced in: Tomsk
VT8 Liquid thermostat
VT8 Liquid thermostat
It is designed to maintain a set temperature of a liquid coolant circulating both in an internal bath and in external closed-type consumers. Feed pump for external closed-type thermostating systems. All-metal stamped tub with a volume of 8 liters and a depth of 150 mm. The stability and uniformity of the temperature in the inner bath is not worse than ± 0.1 ° C. The operating temperature range is +20...+200 °C. Bath volume 8 l Overall dimensions 315x330x400 mm The open part of the bath is 120x200 mm Bath depth 150 mm Weight 13 kg Power consumption 2.2 kW
Produced in: Tomsk
CRYO-VT-80 Low-temperature liquid thermostat
CRYO-VT-80 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling power of 100 W at -80 °C. An internal bath with a volume of 9 liters and a depth of 200 mm. The operating temperature range is -80...+20 °C. Overall dimensions 330x660x820 mm Weight 73 kg Power consumption 4.2 kW.
Produced in: Tomsk