Search

32 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 2
    Manufacturer
  • 3
    Made in
  • 1
    Additional
View:
32 products
Gas radiometer UDG-03D
Gas radiometer UDG-03D
Installation for continuous measurement and transmission over the information network of the value of the volumetric activity of beta-emitting gases (argon, krypton, xenon). It is used in gas-aerosol control systems at nuclear power and fuel cycle facilities. Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon).
Doza
Zelenograd
Produced in: Moscow
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
Dosimeter-radiometer ISS-17D "Finch"
Dosimeter-radiometer ISS-17D "Finch"
Purpose: measurement of the power of ambient dose equivalent (MAED) and ambient dose equivalent (ED) of photon radiation; operational search for sources of ionizing radiation and radioactive materials; measurement of the flux density and fluence of alpha and beta radiation; measurement of surface alpha and beta activity; measurement of the ambient dose equivalent (MAED) power of neutron radiation.
Doza
Zelenograd
Produced in: Moscow
Dosimeter-radiometer DKS-96 (with detection unit BDKS-96b)
Dosimeter-radiometer DKS-96 (with detection unit BDKS-96b)
It is recommended for workplace monitoring when working with medical and industrial X-ray machines and installations, X-ray flaw detectors, X-ray equipment for baggage inspection.
Doza
Zelenograd
Produced in: Moscow
Installation radiometric UDI-1B
Installation radiometric UDI-1B
Installation for continuous automatic monitoring of the concentration of iodine radionuclides in an autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of volumetric activities of iodine radionuclides I-131, I-132, I-133 and I-135 in the air.
Doza
Zelenograd
Produced in: Moscow
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
Measurement of the power of the ambient dose equivalent and the ambient dose equivalent of neutron radiation, as well as simultaneous monitoring of the power of the ambient dose equivalent and the ambient dose equivalent of gamma radiation. A wide energy range Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4 Audible and visual alarm of exceeding threshold levels
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (ALPHA/BETA POLLUTION MONITORS)
High sensitivity Sound, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions A wide range of measurements
Produced in: Belarus, Minsk
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Installation for measuring the volumetric activity of radioactive gases in the air UDG-1B
Purpose: measurement of the volumetric activity of beta-emitting gases (argon, krypton, xenon). Properties: built-in air flow indicator; compensation for the effects of external gamma background; communication interfaces RS-232, RS-485, Ethernet; sound and light alarm of exceeding the set thresholds; working with your own pumping unit or with an external sampling line; setup using a portable computer; periodic verification without disassembly using an exemplary source; availability of discrete output signal of the device; the possibility of connecting an external emergency alarm unit BAS.
Doza
Zelenograd
Produced in: Moscow
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
High sensitivity Audible, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
Installation radiometric UDGB-01
Installation radiometric UDGB-01
The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
Doza
Zelenograd
Produced in: Moscow
RADIOMETER RKS‑AT1329
RADIOMETER RKS‑AT1329
The radiometer allows you to: - measure the total alpha and total beta activity of counting samples based on aerosol analytical filters of the AFA type; - measure the total alpha and total beta activity of "thick-layer" counting samples prepared from the sample substance (for example, by evaporation or by any other method that provides a "thick" sample); - measure the total alpha and total beta activity of "thin-layer" counting samples prepared from the sample substance (for example, by electrolytic deposition); - measure activity, flux density, external alpha and beta radiation for sources of type 1P9, 2P9, 3P9, 1C0, 2C0, 3C0; - control radiation contamination of surfaces by smears. Device control and measurement data processing is performed by an external PC The possibility to use custom calibrations The possibility to select units of measurement LED stabilization of the measuring path Passive lead protection against background radiation The possibility to maintain a measurement database Methodological support of measurements