Search

29 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 3
    Applying
  • Names
  • 2
    Manufacturer
  • 2
    Made in
  • 3
    Additional
View:
29 products
Nitrogen generator "Standard Series"
Nitrogen generator "Standard Series"
The nitrogen adsorption generator is a special equipment designed to produce nitrogen gas from atmospheric air by the method of short-cycle non-heating adsorption. Capacity:1.8—1000 m3/h Purity: 90-99,99 % Pressure: 4-450 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen generator "Ultra Series"
Nitrogen generator "Ultra Series"
The nitrogen adsorption generator is a special equipment designed to produce nitrogen gas from atmospheric air by the method of short-cycle non-heating adsorption. Capacity:1.8—1000 m3/h Purity: 99.99—99.9999 % Pressure: 4-450 bar
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen Generator GA-1200
Nitrogen Generator GA-1200
from 516 000 ₽
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. Technical specifications Volume fraction of nitrogen is not less than 99.0 % by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 1.0 % vol. Volume fraction of water vapor is not more than 0.002 % vol. (20 ppm) Maximum nitrogen capacity: at an inlet air pressure of 7 ati is at least 1380 l/h (23 l/min) The time of setting the operating mode for single-shift operation is no more than 30 min Minimum inlet air pressure is 7 ati Maximum allowable inlet air pressure is 8.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 150 l/min Power consumption is not more than 200 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm Weight is not more than 38 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen Generator GCHA-15-K
Pure nitrogen Generator GCHA-15-K
from 340 800 ₽
The characteristics of the device are similar to the GCHA-18-K model. The difference is the generator capacity of 15 liters /hour. An oil-free compressor is also built into the generator, which ensures complete autonomy of the device. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) The maximum volume of nitrogen production is not less than 15 liters/hour (250 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than, min,* 45 Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 200 VA Overall dimensions, (width x depth x height), not more than, mm, 230x470x510 Weight, not more than, kg 23 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life are at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen generator GA-400
Nitrogen generator GA-400
from 408 000 ₽
Nitrogen generators are designed to create an inert atmosphere, fill low-pressure tanks and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty period of operation of the generator is 12 months from the date of sale by the manufacturer. Technical specifications Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.5 Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity is at least 400 l/h (6.66 l/min) The time of setting the operating mode for single-shift operation is no more than, min, 30 Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 30 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow